AustralianMonitor-AM1200-pwr-sm维修电路原理图.pdf
《AustralianMonitor-AM1200-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《AustralianMonitor-AM1200-pwr-sm维修电路原理图.pdf(58页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 .au SERVICE INFORMATION AM1200 POWER AMPLIFIER CONTENTS: OPERATION MANUAL SPECIFICATIONS COMPONENT Pin 2 = Hot (non-inverting or in phase); Pin 3 = Cold (inverting or reverse phase). 7a.Signal Strapping A male 3-pin X
2、L type connector is provided on channels A and D and is wired in parallel with the female input XLR for strapping / looping signal between amplifiers. 8. Bridge Switch Pushing this switch in engages the BRIDGED/ MONO mode of operation for the relative pair of channels. In this mode, your amplifier w
3、ill only accept signal applied to the Channel-A input XLR (for channels A and B) or signal applied to the Channel-D input XLR (for channels D and C). Channel-A will now control the level of the A/B bridged pair and Channel-D will now control the level of the D/C bridged pair. Speaker termination sho
4、uld be sourced from the red binding-post outputs. 9. SPEAKON Output Connector The NEUTRIK (NL4MP) 4 way SPEAKON connector is provided as the main speaker output termination. This emerging standard of loudspeaker to amplifier connection allows access to both channels of the amplifier via the one conn
5、ector for bi-amp applications. Channel-A (or D) is considered the dominant channel and has both channels wired to the Speakon connector. See the installation section of this manual for detailed information on Speakon wiring. 9a.Binding Post Outputs Binding posts (banana jacks) are provided for speak
6、er output termination with banana plugs or bare wire. The red post is used as positive and the black post is used as negative. 10.Mains Lead Your amplifier is supplied with a heavy duty mains Controls BLUE=NEUTRAL; GREEN AND YELLOW=EARTH. ! CAUTION ! Your amplifier must always be earthed! 11.Mains C
7、ircuit Breaker A “push to reset” thermal acting circuit breaker is supplied on your amplifier providing overall protection of your amplifiers power supply and the interconnecting mains. The breaker will isolate the active mains conductor in the event of a high current internal fault or in continued
8、overload conditions. The breaker will not be able to be reset immediately after tripping. A cool down period of around 30 seconds is required before the breaker will reset back into circuit. If the breaker trips immediately after a reset, then a fault may have developed within the amplifier. 12.D.C.
9、 Rail Fuses Your AM1200 amplifier is fitted with 8 Amp fuses per rail - per channel, as overload protection for the output stage of your amplifier. These fuses are in series with the high current supply rails to the amplifiers output stage and will blow when: 1) An internal fault exists; 2) There is
10、 a sustained overload; 3) There is a sustained short circuit; 4) Sustained load fault. Note: The front panel Fault Indicator will illuminate and pulse in sync. with the program source if the negative supply Rail fuse blows. Distortion will result and the front panel Status LED will illuminate RED if
11、 the Positive Rail fuse blows. Replace only with 8 Amp, 3AG fast acting type fuses. Figure 4 Dimensions 10 Installation 3. Installation Mains Lead Wiring WARNING Your amplifier must be earthed at all times! When you first receive your amplifier it may not have a mains plug attached. You must ensure
12、that an appropriate plug is used and corresponds with the amplifiers current (ampere) requirements and meets the approval of your local energy authority. Please refer termination of this lead to qualified personnel. Australian Monitor takes no responsibility for any damage or harm resulting from imp
13、roper termination of this lead! The wires in the mains lead are coloured in accordance with the following code: GREEN AND YELLOW = EARTH Connect to the terminal marked with the letter E, with the EARTH SYMBOL or coloured GREEN. BLUE = NEUTRAL Connect to the terminal marked with the letter N (or colo
14、ured WHITE in USA and Canada, or coloured BLACK in the United Kingdom). BROWN = ACTIVE (LIVE) Connect to the terminal marked with the letter A or L (or coloured BLACK in USA and Canada or coloured RED in the United Kingdom). Power Requirements Mains VoltageCircuit Breaker Rating 100 to 120 volts20 A
15、mps 220 to 240 volts10 Amps Power Consumption at idle= 250 Watts Consumption at rated 4 ohm power= 2300 Watts Ensure that your mains voltage is the same as the rear panel mains voltage marker (+/- 10%). Mounting Your amplifier is designed for standard 19 rack mounting and occupies 3 EIA rack units (
16、5.25). The mounting centres are: Vertical:2.25(57.15mm) Horizontal: 18.15 (461.1mm) to 18.62 (473.0mm). The slots in the mounting flange will accept bolt diameters up to 1/4 (6.35mm). We recommend that you provide additional support for the amplifier, especially if road use is planned, as the weight
17、 can bend some racks otherwise. This support can be provided by secure shelving, support rails or a rear rack mounting strip to match up with the rear rack mount points provided on your amplifier. Cooling Each pair of channels in your AM1200 amplifier is cooled by an axial fan which draws cool air f
18、rom the front of the unit and expels the heated air via the rear of the unit. These units offer two speed fans which run at half speed, switching to full speed when the internal heatsink temperature exceeds 600 C (1280 F). An unrestricted airflow into and out from the unit must be provided. Any rest
19、riction of the air flow will cause heat to build up within the unit and possibly force the unit into its thermal shutdown mode. If the units are to be operated in an environment where the airflow is restricted such as sealed racks or even when running 2 ohm loads, the cooling should be supplemented
20、by extra cooling fans to evacuate the heated air and aid the flow of cool air through the unit. Input Wiring IMPORTANT! Do not directly connect pin 1 on the amplifiers input or strapping XLR, to the amplifiers chassis, speaker ground or power ground! NOTE: Input signal ground is not to be used as a
21、safety ground (earth). The input to your amplifier is a balanced 3-pin system and requires all three pins to be connected. Only high quality twin-core shielded cable should be used. When wiring for a balanced source the connector going to the input of your amplifier should be wired as follows: Pin 2
22、 =HOT (In Phase - non inverting). Pin 3 =COLD (Reverse Phase - inverting). Pin 1 =GROUND / SHIELD. When wiring from an unbalanced source you must ensure that pin 3 is connected to pin 1 (input ground), either by linking the pins in the input connector or by the source equipments output wiring. When
23、wiring for an unbalanced source: Pin 2 =HOT (in phase with the amplifiers output), Pin 3 =GROUND/SHIELD (joins to pin 1). Pin 1 =GROUND/SHIELD Installation 11 connector for speaker output, use only the mating NEUTRIK NL4FC in-line connector. This connector is designed so that both channels can be so
24、urced from a single connector. Four SPEAKON connectors are provided on the amplifier. The Channel-A SPEAKON carries both speaker output signals for Channel-A S$ritches the Active only.It is rated at 24OVll5A resistive and 1/4 H.p. 90Deg. C/ 10oDeg. C THERHAL SENSORS r These are normally closed devic
- 配套讲稿: