AustralianMonitor-DCM250-pwr-sm维修电路原理图.pdf
《AustralianMonitor-DCM250-pwr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《AustralianMonitor-DCM250-pwr-sm维修电路原理图.pdf(23页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 .au SERVICE INFORMATION DCM250 POWER AMPLIFIER CONTENTS: OPERATION MANUAL CIRCUIT DESCRIPTION SET-UP / TEST PROCEDURE SCHEMATIC DIAGRAMS PCB OVERLAYS COMPONENT LISTS RadioFans.CN 收音机爱 好者资料库 DCM250 250w Power Amplifier
2、 Operating Manual TEM PFAILON 24211815129630+3 HIMAINS D C M 2 5 0 RadioFans.CN 收音机爱 好者资料库 Product Description The DCM250 is a 250 watt power amplifier designed for commercial installations. It can be used for either low impedance (4 ohm) or 100v line speaker systems. The amplifier can be mounted in
3、 a standard 19” equipment rack or it can be used on a shelf or table. The DCM250 features a line level input (with parallel output) and is normally used with mixers, mixer amplifiers or other power amplifiers. The DCM250 will operate from 230/240 VAC 50 Hz (115 VAC 60 Hz with factory modification) o
4、r 24 VDC and will meet its full performance specification on either voltage supply. The DCM250 also features a DC battery trickle charge facility, auto-sensing fan cooling, plus overload, short circuit and over temperature protection. DCM250, 250 Watt Power Amplifier Front Panel Features Power Switc
5、h The rocker switch located in the front centre of the panel turns AC power on to the DCM250. Rocking the power switch to the right to turns the AC power on. When the AC power is on, a blue LED will glow. Please note that this switch does not switch DC voltage. If a DC voltage supply is connected to
6、 the DCM250, the amplifier will operate as soon as the connection is made, regardless of the position of the AC power switch. If both an AC and DC voltage supply are connected and you rock the AC power switch to the off position, the DCM250 will automatically continue to operate normally from the DC
7、 supply (and the mains failure LED will also glow under these conditions). Level Control The output level control is located in the centre of the front panel, just to the left of the mains rocker switch (re- cessed screwdriver adjustable pot). Turning the control clockwise will increase the output o
8、f the DCM250 towards its maximum output level while turning the control counter-clockwise will decrease the output level. Adjust this control for the desired output level depending on the level of the input signal (from a mixer or other signal source). The factory default setting for this control is
9、 such that a 1 volt input will give a 100 volt output. Amplifier Status Display The amplifier status display highlights the operating condition of the DCM250.The status display indicates: High Temperature: This red LED glows if one of the fans has failed and the amplifier has been shut down by its t
10、emperature control circuitry. If this LED is glowing and the fans have not failed, it means that the amplifier is operating in an ambient environment that is too hot for fan cooling to make any difference to the temperature of the amplifier. Power: This LED glows blue if AC power is switched on to t
11、he DCM250. Note that this LED does not indicate the presence of a DC supply voltage. TEM PFAILON 24211815129630+3 HIMAINS D C M 2 5 0 Rear Panel Features AC Power Inlet The 3 pin IEC power inlet is located on the bottom left of the rear panel and accepts a standard mains power lead fitted with an IE
12、C connector. Before plugging in a power lead, please check the rear panel of the amplifier to ensure that the voltage label shows the correct AC operating voltage for your part of the world. The inlet is equipped with an in-built AC fuse holder fitted with a 6 Amp slow blow fuse plus a spare fuse. P
13、lease ensure that the mains power cord is disconnected before attempting to check or replace this fuse. Power consumption is 400 VA (max). Speaker Output Terminal Strip Located on the top left of the rear panel is the speaker output terminal strip. Reading from left to right, the connections are: CO
14、MCommon or “-” for low impedance speaker loads (4 ohms). 4The “+” for 4 ohm speaker loads (use with common) COMCommon or “-” for 100v speaker loads (maximum load of 40 ohms at 100v) 100The “+” for 100v line speaker loads (use with common) Please ensure that the correct “Common” is used. Low impedanc
15、e and 100v loads can be used simultaneously but please pay careful attention to the overall speaker load. When used individually, the low impedance load should be 4 ohms or higher while the 100v line load should not fall below 40 ohms. When both outputs are used simultanously, ensure that neither ou
16、tput is loaded to maximum. 24 Volt Power Located on the rear panel are the red and black connection posts for 24v power. This feature can be used as either a back- up facility (if mains power fails) or for applications where AC power is not available. The left side red post is the + (positive) termi
17、nal while the right side black post is the - (negative) terminal. The DC current drain is 15 Amps maximum at full power. This socket also provides trickle charge to a DC battery supply (if connected) when the DCM250 is operated from AC mains power. The level of trickle charge is 300 mA, maximum. Mai
18、ns Failure: The LED glows red if there is a failure in the AC mains power supply. However, this LED will only glow if there is a DC supply voltage present. If no DC supply voltage is present then this LED will not glow. Output Level VU Meter: A 10 segment LED VU meter is provided to give an indicati
19、on of the output signal level of the amplifier from -25 to +3 dB. During normal operation, the LEDs will oscillate with changes in the program signal. Care should be taken to avoid more than occasional illumination of the red LEDs. If the LEDs in the red zone are lit continually, then the output lev
20、el control (or the level of the input signal to the DCM250) should be adjusted to reduce the output level. Too much output level can cause distortion, activate the internal limiter or possibly damage the connected speaker system. 230 V CC4100NC OHM AC FUSE 6A S/B DC FUSE 2 X 10A S/B 24 VDC INPUT ENG
21、INEERED BY AUDIO TELEX COMMUNICATIONS PTY LTD SYDNEY AUSTRALIA VOLT NC 240 V Twin DC Fuse Receptacles Located on the rear panel are two DC fuse receptacles. Access each DC fuse by turning the cap counter-clockwise with a screwdriver. The value of the fuse is 10 Amps slow blow. Please ensure that the
22、 AC power switch is in the off position and that the mains power cord is disconnected before attempting to check or replace this fuse Cooling Fan (Air Intake) The cooling fans are temperature sensitive and will only switch on when the temperature of the DCM250 had reached a pre-determined range. The
23、 fan will stay on and only switch off again once the temperature of the DCM250 has fallen below a pre-determined level. If the DCM250 is operating continually at conservative levels and proper load conditions, it is possible that the cooling fan will not switch on at any time during normal operation
24、. When operating, the fan works with air flow from the front to the rear of the DCM250. Fuse Sizes Mains, 240 VAC : 6 Amperes Slow Blow. XLR Audio Input and Parallel Output The input to the DCM250 is transformer balanced 10K ohms. When signal is connected to one XLR, the other XLR becomes a line lev