1、Technical Service Manual RMX Series 2RU models RMX 850 RMX 1450 RMX 1850HD RMX 2450 *TD-000098-00* TD-000098-00 Rev. C QSC Audio Products, LLC Costa Mesa, CA 92626 USA RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 RMX Series Technical Service Manual (2RU models)1 TD-000098-00 rev. C QSC Audio Prod
2、ucts, LLC Technical Services Group Phone:1-800 QSC AUDIO (1-800-772-2834) USA only +1 (714) 957-7150 Fax:+1 (714) 754-6173 Postal:1665 MacArthur Blvd. Costa Mesa, California 92626 USA E-mail:tech_ Web: (product information and support) (parts and accessory sales) RMX 850 RMX 1450 RMX 1850HD RMX 2450
3、 RMX Series Technical Service Manual Copyright 2001, 2002, 2005, 2008 QSC Audio Products, LLC All rights reserved. Document # TD-000098-00, Rev. C. Released June 2008. RadioFans.CN 收音机爱 好者资料库 2QSC Audio Products, LLC RMX 850RMX 1450RMX 1850HDRMX 2450 OUTPUT POWER in watts FTC: 20 Hz20 kHz 0.1% THD,
4、both channels driven 8 per channel185260350450 4 per channel280400550650 EIA: 1 kHz 0.1% THD, both channels driven 8 per channel200280360500 4 per channel300450600750 1 kHz 1% THD, typical, both channels driven 2 per channel4307009001200 Bridge Mono: 8, 20 Hz20 kHz, 0.1% THD5308001300 8, 1 kHz, 0.1%
5、 THD60090012001500 4, 1 kHz, 1% THD, typical830140018002400 DYNAMIC HEADROOM2 dB 4 DISTORTION SMPTE-IM 0.01% 0.01% 0.02% 300 8 NOISE (unweighted 20 Hz to 20 kHz, below rated output)100 dB100 dB100 dB100 dB VOLTAGE GAIN31.6 (30 dB)40 (32 dB)46 (33 dB)50 (34 dB) INPUT SENSITIVITY, V RMS full rated pow
6、er 81.15v (+3.4 dBu)1.15v (+3.4 dBu)1.16v (+3.5 dBu)1.23v (+4.0 dBu) INPUT IMPEDANCE10 k unbalanced 20 k balanced CONTROLSFront: AC switch, Ch. 1 and Ch. 2 gain Rear: 10-position DIP switch INDICATORSPOWER:Green LEDCLIP:Red LED, 1 per channel SIGNAL:Yellow LED, 1 per channel CONNECTORSInput:Active b
7、alanced; XLR and (6.3 mm) TRS, tip and pin 2 positive, and barrier strip Output:“Touch-Proof” binding posts and Neutrik Speakon COOLINGContinuously variable speed fan, back-to-front air flow AMPLIFIER PROTECTIONFull short circuit, open circuit, thermal, ultrasonic, and RF protection Stable into reac
8、tive or mismatched loads LOAD PROTECTIONTurn-on/turn-off muting (all models) AC couplingAC couplingTriac crowbar (each channel)Triac crowbar (each channel) OUTPUT CIRCUIT TYPEABABHH AB: Class AB+B complementary linear output H: Class AB+B complementary linear output with Class H 2-step high efficien
9、cy circuit DIMENSIONS19.0 (48.3 cm) wide, 3.5 (8.9 cm) tall (2 rack spaces) 15.9 (40 cm) deep (rack mounting to rear support ears) WEIGHTShipping:41 lb. (18.6 kg)46 lb. (20.9 kg)50.5 lb. (23 kg)50.5 lb. (23 kg) Net:35 lb. (15.9 kg)40 lb. (18.2 kg)44.5 lb. (20.2 kg)44.5 lb. (20.2 kg) POWER REQUIREMEN
10、TSAvailable for 120 or 220240 VAC, 50/60 Hz POWER CONSUMPTION 120 VAC (both channels driven) Multiply currents by 0.5 for 230V units l ac i pyT 1 l l uF 2 xaM 3 e l d IA5 . 0 8 A3A1 . 4A4 . 7 4 A5 . 4A6 . 6A5 . 11 2 A5 . 6*A5 . 9*A71 l ac i pyT 1 l l uF 2 xaM 3 e l d IA5 . 0 8 A7 . 3A4 . 5A01 4 A6A6
11、 . 9A61 2 A3 . 9*A7 . 41*A52 l ac i pyT 1 l l uF 2 xaM 3 e l d IA6 . 0 8 A4A7 . 9A4 . 61 4 A3 . 6A6 . 51A72 2 A2 . 9*A32*A14 RMX Series Performance Specifications Typical 1 Full 2 Max 3 Idle0.8 A 8 3.9 A6.9 A12.6 A 4 6.1 A11.2 A20.7 A 2 8.7 A16.6 A*32 A* 1. TypicalMeasured with pink noise signal on
12、all channels at 1/8 of full average power. Producing peaks that occasionally reach the amps clipping point, this level approximates the maximum operating level before clipping affects sound quality. These data would be the amps typical worst-case current. 2. FullMeasured with pink noise signal on al
13、l channels at 1/3 of full average power. Music at this level would typically produce massive clipping. In a class B amplifier, this would be the approximate point of maximum heat production. 3. MaxMeasured with continuous sine wave signal on all channels at a point of slight clipping (1% THD). This
14、represents a “test bench” scenario and does not resemble any real-world usage. US patents pendingSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE RadioFans.CN 收音机爱 好者资料库 RMX Series Technical Service Manual (2RU models)3 TD-000098-00 rev. C Table of Contents RMX Series Performance Specifications. 2 1.
15、 Introduction . 5 1.1 Restriction of Hazardous Substances Directive (RoHS). 5 1.2 QSC serial numbers . 5 1.3 Service bulletins. 5 1.4 The well-equipped service bench. 6 1.5 Working with surface-mount components . 6 1.6 Series description . 8 1.7 Technical descriptions and theory of operation . 8 2.
16、Component identification and pinout . 11 3. Troubleshooting: Symptoms, causes, the last five digits are the sequential identifying number for each individual amplifier. For example, a serial number of 0807xxxxx would indicate that the amplifier was built in 08/2007, or August 2007. The date code is
17、important for determining whether an amplifier is subject to a service bulletin, covered by a warranty (in the absence of original purchase records), etc. The amplifiers serial number can be found on a label on the rear panel. The label also indicates the model number, power rating, 4 current draw,
18、and the AC mains voltage the amplifier was made for. Certain design changes that the RMX amplifiers have undergone commenced with a particular date code; for example, the RMX amplifiers with a date code of 0406 or later conform to the European Unions RoHS Directive and must be serviced only with lea
19、d-free solder and soldering irons that are not contami- nated with lead or other heavy metals covered by the directive. 1.1 Restriction of Hazardous Substances Directive (RoHS) Since April 2006, all RMX Series amplifiers are manufactured to conform to the European Unions RoHS Directive, which reduce
20、s the amount of hazardous substances allowed in products for sale within its member nations. In electronic equipment such as audio power amplifiers, this applies primarily to certain toxic heavy metals, such as lead, which may be present in electronic components, solder, and other parts. RoHS-compli
21、ant materials When servicing RoHS-compliant amplifiers, it is important for the service technician to use only RoHS-compliant components and solder (lead-free). All replacement parts provided by QSC for RoHS-compliant products are certified as RoHS compliant. RoHS-compliant tools Soldering irons and
22、 desoldering apparatus used on RoHS-compliant products must also not be contaminated by hazardous substances, such as lead. Therefore, you cannot use the same soldering and desoldering tools for RoHS-compliant products and solder as you do for non-compliant products and solder. You must either use s