《Pioneer-VSX515S-avr-sm维修电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-VSX515S-avr-sm维修电路原理图.pdf(79页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ORDER NO. PIONEER CORPORATION 4-1, Meguro 1-chome, Meguro-ku, Tokyo 153-8654, Japan PIONEER ELECTRONICS (USA) INC. P.O. Box 1760, Long Beach, CA 90801-1760, U.S.A. PIONEER EUROPE NV Haven 1087, Keetberglaan 1, 9120 Melsele, Belgium PIONEER ELECTRONICS ASIACENTRE PTE. LTD. 253 Alexandra Road, #04-01
2、, Singapore 159936 PIONEER CORPORATION 2005 UPDOWN MULTI JOG MASTER VOLUME ENTER AUDIO/VIDEOMULTI-CHANNELRECEIVER STANDBY/ON PHONES DVD/LDDVD 5.1TV/SATDVR/VCRCDCD-R/TAPE/MDFMAM VSX-515-K RRV3092 AUDIO/VIDEO MULTI-CHANNEL RECEIVER VSX-515-K VSX-515-S THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S
3、) AND TYPE(S). ModelTypePower RequirementRemarks VSX-515-KKUCXJAC 120V VSX-515-SKUCXJAC 120V For details, refer to Important Check Points for Good Servicing. ZZK MAR. 2004 printed in Japan RadioFans.CN 收音机爱 好者资料库 VSX-515-K 2 1234 1234 C D F A B E SAFETY INFORMATION This service manual is intended fo
4、r qualified service technicians; it is not meant for the casual do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely a
5、ffect the safety and reliability of the product and may void the warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING This product contains lead in solder and
6、certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm. Health & Safety Code Section 25249.6 Proposition 65 NOTICE (FOR CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB
7、 indicate that replacement parts must be of identical designation. REMARQUE (POUR MODLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur CCI indiquent que les pices de remplacement doivent avoir la mme dsignation. ANY MEASUREMENTS NOT WITHIN THE L
8、IMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURN- ING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual
9、inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such features are identifi
10、ed by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, o
11、r other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from P
12、IONEER. (FOR USA MODEL ONLY) 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester suc
13、h as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60 Hz outlet and turn the AC power switch on. Any cur
14、rent measured must not exceed 0.5 mA. Device under test Leakage current tester Earth ground Reading should not be above 0.5 mA Also test with plug reversed (Using AC adapter plug as required) Test all exposed metal surfaces AC Leakage Test RadioFans.CN 收音机爱 好者资料库 VSX-515-K 3 5678 56 7 8 C D F A B E
15、Important Check Points for Good Servicing In this manual, procedures that must be performed during repairs are marked with the below symbol. Please be sure to confirm and follow these procedures. 1. Product safety Please conform to product regulations (such as safety and radiation regulations), and
16、maintain a safe servicing environment by following the safety instructions described in this manual. 1 Use specified parts for repair. Use genuine parts. Be sure to use important parts for safety. 2 Do not perform modifications without proper instructions. Please follow the specified safety methods