1、NAD SERVICE MANUAL ? DIGITAL PREAMP DAC ? DIGITAL PREAMP DAC RadioFans.CN 收音机爱 好者资料库 TABLE OF CONTENTS DESCRIPTION P A G E SERVICE CAUTION.3-4 SPECIFICATIONS. 5 WIRING DIAGRAM.6 BLOCK DIAGRAM. .7-9 .12-28 8 PCB LAYOUT.29-40 ELECTRICAL PARTS LIST.41-67 EXPLODED VIEW.68 EXPLODED VIEW PARTS LIST.69 CIR
2、CUIT DIAGRAMS TROUBLE SHOOTING A GUIDE.10 TROUBLE SHOOTING B GUIDE.11 PACKING ACCESSORY SECTION.70 RadioFans.CN 收音机爱 好者资料库 3 SUBJECT: GRAPHIC SYMBOLS PRODUCT SAFETY SERVICING GUIDELINES FOR AUDIO PRODUCTS A.C. VOLTMETER GOOD EARTH GROUND SUCH AS THE WATER PIPE. CONDUIT. ETC PLACE THIS PROBE ON EACH
3、EXPOSED METAL PART CAUTION : DO NOT ATTEMPT TO MODIFY THIS PRODUCT IN ANY WAY, NEVER PERFORM CUSTOM- IZED INSTALLATIONS WITHOUT MANUFACTURERS APPROVAL. UNAUTHORIZED MODIFICATIONS WILL NOT ONLY VOID THE WARRANTY, BUT MAY LEAD TO YOUR BEING LIABLE FOR ANY RESULTING PROP- ERTY DAMAGE OR USER INJURY. SE
4、RVICE WORK SHOULD BE PERFORMED ONLY AFTER YOU ARE THOROUGHLY FAMILIAR WITH ALL OF THE FOLLOWING SAFETY CHECKS AND SERVIC- ING GUIDELINES. TO DO OTHERWISE,INCREASES THE RISK OF POTENTIAL HAZARDS AND INJURY TO THE USER. WHILE SERVICING, USE AN ISOLATION TRANS- FORMER FOR PROTECTION FROM A.C. LINESHOCK
5、. SAFETY CHECKS AFTER THE ORIGINAL SERVICE PROBLEM HAS BEEN CORRCTED. A CHECK SHOULD BE MADE OF THE FOLLOWING. SUBJECT : FIRE CONNECT A 1500 OHM 10 WATT RESISTOR, PARALLELED BY A .15 MFD. 150.V A.C TYPE CAPACITOR BETWEEN A KNOWN GOOD EARTH GROUND (WATER PIPE, CONDUIT,ETC.) AND THE EXPOSED METALLIC P
6、ARTS, ONE AT A TIME. MEASURE THE A.C. VOLT- AGE ACROSS THE COMBINATION OF 1500OHM RESISTOR AND .15 MFD CAPACITOR. REVERSE THE A.C. PLUG AND REPEAT A.C. VOLTAGE MEASURE- MENTS FOR EACH EXPOSED METALLIC PART. VOLT- AGE MEASURED MUST NOT EXCEED 75 VOLTS R.M.S. THIS CORRESPONDS TO 0.5 MILLIAMP A.C ANY V
7、ALUE EXCEEDING THIS LIMIT CONSTITUTES A POTENTIAL SHOCK HAZARD AND MUST BE COR- RECTED IMMEDIATELY. THE LIGHTNING FLASH WITH APROWHEAD SYMBOL. WITHIN AN EQUILATERAL TRIANGLE, IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF UNINSULATED “DANGEROUS VOLTAGE” THAT MAY BE OF SUFFICIENT MAGNI
8、TUDE TO CONSTITUTE A RISK OF ELECTRIC SHOCK. THE EXCLAMATION POINT WITHIN AN EQUILATERAL TRIANGLE IS INTENDED TO ALERT THE SERVICE PERSONNEL TO THE PRESENCE OF IMPORTANT SAFETY INFORMATION IN SERVICE LITERATURE. RadioFans.CN 收音机爱 好者资料库 SERVICING PRECAUTIONS CAUTION:Before servicing the Stereo amplif
9、ier covered by this service data and its supplements and addends, read and follow the SAFETY PRECAUTIONS. NOTE: if unforeseen circumstances create conflict between the following servicing precautions and any of the safety precautions in this publication, always follow the safety precautions. Remembe
10、r Safety First: General Servicing Precautions 1. Always unplug the Stereo amplifier AC power cord from the AC power source before: (1) Removing or reinstalling any component, circuit board, module, or any other assembly. (2) Disconnecting or reconnecting any internal electrical plug or other electri
11、cal connection. (3) Connecting a test substitute in parallel with an electrolytic capacitor. Caution: A wrong part substitute or incorrect polarity installation of electrolytic capacitors may result in an explosion hazard. 2. Do not spray chemicals on or near this Stereo amplifier or any of its asse
12、mblies. 3. Unless specified otherwise in this service data, clean electrical contacts by applying an appropriate contact cleaning solution to the contacts with a pipe cleaner, cottontipped swab, or comparable soft applicator. Unless specified otherwise in this service data, lubrication of contacts i
13、s not required. 4. Do not defeat any plug/socket B+ voltage interlocks with which instruments covered by this service manual might be equipped. 5. Do not apply AC power to this Stereo amplifier and/or any of its electrical assemblies unless all solid-state device heat sinks are correctly installed.
14、6. Always connect test instrument ground lead to the appropriate ground before connecting the test instrument positive lead. Always remove the test instrument ground lead last. Insulation Checking Procedure Disconnect the attachment plug from the AC outlet and turn the power on. Connect an insulatio
15、n resistance meter (500V) to the blades of the attachment plug. The insulation resistance between each blade of the attachment plug and accessible conductive parts (Note 1) should be more than 1 M-ohm. Note 1: Accessible Conductive Parts including Metal panels, Input terminals, Earphone jacks, etc.
16、Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical Es devices are integrated circuits and some field effect transistors and se
17、miconductor chip components. The following techniques should be used to help reduce the incidence of component damage caused by static electricity. 1. Immediately before handing any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touchin
18、g a known earth ground. Alternatively, obtain and wear a commercially available discharging wrist strap device, which should be removed for potential shock reason prior to applying power to the unit under test. 2. After removing an electrical assembly equipped with ES devices, place the assembly on
19、a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly. 3. Use only a grounded-tip soldering iron to solder or unsolder ES devices. 4. Use only an antistatic solder removal device. Some solder removal devices not classified a “anti-static” can
20、 generate electrical charges sufficient to damage ES devices. 5. Do not use freonpropelled chemicals. These can generate electrical charge sufficient to damage ES devices. 6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
21、 replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil, or comparable conductive material). 7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material to the chassis or circu
22、it assembly into which the device will be installed. Caution: Be sure no power is applied to the chassis or circuit, and observe all other safety precautions. 8.Minimize bodily motions when handing unpackaged replacement ES devices. (Normally harmless motion such as the brushing together of your clo
23、thes fabric or the lifting of your foot from a carpeted floor can generate static electricity sufficient to damage an ES device.) 4 RadioFans.CN 收音机爱 好者资料库 SPECIFICATIONS ? ? 5 DIGITAL INPUT (COAXIAL, OPTICAL, USB)M12 Rated Distortion (THD+N with AES 17 filter)-115dB (ref. 0dBFS Volume -1dB) Signal
24、/ Noise Ratio-125dB (ref. 0dBFS 2V out) Output Level2V (ref. input 0dBFS) INPUTS/OUTPUTS XLR - AES/EBU S/PDIF Coaxial x 2 Optical x 2 USB Class 2 Audio: asynchronous 24/192 support DD AP-1 Analogue Phono Module IR In Trigger In12V 20% Trigger Out12V 20% GENERAL Idle Power26W Standby PowerA H : A-B D
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAD M12 pre sm 维修 电路 原理图