1、Hi-Fi AM-FM Stereo Receiver SERVICE MANUAL MODELDRA-395 AM-FM STEREO RECEIVER SAFETY PRECAUTIONS. 2 SPECIFICATIONS . 2 DISASSEMBLY . 3 ADJUSTMENT. 4,5 BLOCK DIAGRAM . 6 LEVEL DIAGRAM . 7 SEMICONDUCTORS .812 PRINTED WIRING BOARDS .1317 NOTE FOR PARTS LIST. 18 PARTS LIST OF P.W.B. UNIT ASSY .1924 EXPL
2、ODED VIEW . 25 PARTS LIST OF EXPLODED VIEW . 26 PACKING VIEW . 27 TABLE OF CONTENTS ?Some illustrations using in this service manual are slightly different from the actual set. PARTS LIST OF PACKING & ACCESSORIES . 27 WIRING DIAGRAM. 28 SCHEMATIC DIAGRAMS .2934 (1/6)INPUT UNIT . 29 (2/6)VOLUME UNIT
3、. 30 (3/6)MAIN UNIT . 31 (4/6)VIDEO UNIT . 32 CONNECTOR UNIT . 32 (5/6)FRONT UNIT. 33 SWITCH UNIT . 33 POWER SW/HP UNIT. 33 (6/6)TUNER UNIT. 34 For U.S.A. & Canada model 14-14, AKASAKA 4-CHOME, MINATO-KU, TOKYO 107-8011 JAPAN Telephone: 03 (3584) 8111 X0118 842 NC 0108 RadioFans.CN 2 DRA-395 SPECIFI
4、CATIONS ? ? ? ? ? Audio Section (Power Amplifier) Rated output:80W + 80W (8/ohms, 20Hz 20kHz with 0.08% T.H.D.) Output terminals:A or B4 to 16/ohms A + B8 to 16/ohms (Analog) LINE input - PRE OUT Input sensitivity/input impedance:200mV/47k/kohms Frequency response:10Hz 50kHz: 1.5dB S/N ratio:100 dB
5、(IHF-A weighted) Total harmonic distortion:0.009% (3dB at rated output, 8/ohms) (1kHz) Rated output:1.2V PHONO input - REC OUT Input sensitivity/input impedance:2.5mV/47k/kohms RIAA deviation:0.5dB (20Hz 20kHz) S/N ratio:74dB (IHF-A weighted, with 5mV input) Total harmonic distortion:0.03% (1kHz, 3V
6、) Rated output/Maximum output:150mV/7V ? ? ? ? ? Video Section (Standard Video Jacks) Input/output level and impedance:1V p-p, 75/ohms Frequency response:5Hz 10MHz +1, 3dB ? ? ? ? ? Tuner Section FM (note: V at 75/ohms, 0dBf = 110-15W)AM Receiving range:87.50MHz 107.90 MHz520kHz 1710kHz Usable sensi
7、tivity:1.4V (14.2dBf)18V 50dB quieting sensitivity:MONO2.8V (20.2dBf) STEREO23V (38.5dBf) S/N ratio:MONO80dB (IHF-A weighted) STEREO75dB (IHF-A weighted) Total harmonic distortion:MONO0.15% (1kHz) STEREO0.3% (1kHz) ? ? ? ? ? General Power supply:AC120V, 60Hz Power consumption:3.39A Maximum external
8、dimensions:434 (W) 147 (H) 417 (D) mm (17-1/16 5-25/32 16-7/16) Weight:9.7kg (21lbs 6oz) ? ? ? ? ? Remote Control Unit (RC-894) Batteries:R03/AAA Type (two batteries) External dimensions:64 (W) 206 (H) 19 (D) mm (2-13/64 8-9/32 3/4) Weight:140g (Approx. 4.9 oz) (including batteries) * For purposes o
9、f improvement, specifications and design are subject to change without notice. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Before returning the unit to the customer, make sure you make either (1
10、) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective. RadioFans.CN 3 DRA-395 DISASSEMBLY (Follow the procedure below in rever
11、se order when reassembling) Top Cover Remove 6 screws 1 and 3 screws 2, detach the Top Cover in the arrow direction. Top Cover Front Panel 1. Remove 4 screws 3 and 2 screws 4. 2. Detach the Front Panel in the arrow direction. 2 1 1 3 Rear Panel 1. Remove cord bushing 5 from the Rear Panel. 2. Remove
12、 26 screws 6. 3. Detach the Rear Panel in the arrow direction. 4 Front Panel Rear Panel 5 6 6 6 RadioFans.CN 4 DRA-395 FM ALIGNMENT InputOutputAdjustment Step Alignment Item Tuning Frequency Setting TypeFrequency Input Level ModulationCouplingTypeConnect toPointsAdjust to 1 Center Adjustment 98.1MHz
13、 (98.0MHz) FM SSG98.1MHz60dB Mono 1kHz 100% Antenna Terminal Digital Voltmeter R471T402 50mV 2Distortion 98.1MHz (98.0MHz) FM SSG98.1MHz60dB Mono 1kHz 100% Antenna Terminal Distortion Meter Output Terminal (L) T403 Minimum Distortion 3Repeat Steps 1 and 2 4Signal Level 98.1MHz (98.0MHz) FM SSG98.1MH
14、z20dBOFF Antenna Terminal Light “TUNED” on FL Display VR402 ADJUSTMENT Tuner Section CONNECTION DIAGRAM OF MEASURING INSTRUMENTS ? FM STEREO MODULATOR FM SSG Digital Voltmeter 75ohm T402T403 IC402 VR402 TUNER BD R471 20+14 10dB ? AM T402T403 IC402 TUNER BD R471 VR401 AM ALIGNMENT OutputAdjustment St
15、ep Alignment Item FrequencyInput TypeConnect toPointsAdjust to Remarks 1Signal Level 999 (1000) kHz AM SSGVR401 Light “TUNED” on FL Display SSG OUTPUT 74dB (EMF) RadioFans.CN 5 DRA-395 Audio Section Idling Current Required measurement equipment : DC Voltmeter Preparation (1)Avoid direct blow from an
16、 air conditioner or an electric fan, and adjust the unit at normal room tempereture 15 C 30 C (59 F 86 F). (2)Presetting G POWER (Power sourse switch)OFF G SPEAKER (Speaker terminal)No load (Do not connect speaker, dummy resistor, etc.) Adjustment (1)Remove top cover and set VR101, VR102 on Amp. Uni
17、t at full counterclockwise ( ) position. (2)Connect DC Voltmeter to test points (Lch: TP101, Rch: TP102). (3)Connect power cord to AC Line, and turn power switch ON. (4)Presetting.MASTER VOLUME : - counterclockwise ( min.) FUNCTION: CD (5)Within 2 minutes after the power on, turn VR101 clockwise ( )
18、 to adjust the TEST POINT voltage to 1.5 mV 0.5 mV DC. (6)After 10 minutes from the preset above, turn VR101 to set the voltage to 2.5 mV 0.5 mV DC. (7)Adjust the Variable Resistors of other channels in the same way. VR101 TP101 VR102 TP102 Lch Rch RadioFans.CN 87654321 A B C D E DRA-395 6 BLOCK DIA
19、GRAM RadioFans.CN CD 1 1 2 3 8 4 6 5 8 7 4 7 6 5 8 4 6 5 8 7 4 1 1 1 ATT MUTE POWER AMP MAIN VOL INPUT BUFFER AMP ATT 1 1 1 1 MAIN MULTI ROOM CD IN -18dB VOL 00 +15.5dB -35.5dB +16.2dB +27dB SPK OUT 2.83V (1W/8ohms) H/P OUT 47mV (1W/8ohms) MULTI ROOM OUT 1.2V (200mV) (200mV) SPK OUT H/P OUT MULTI OU
20、T 87654321 A B C D E DRA-395 7 LEVEL DIAGRAM RadioFans.CN 130 31 50 5180 81 100 CXP82840-319Q Terminal Function SEMICONDUCTORS ? ? ? ? ? ICs CXP82840-319Q (IC900) 1G2/A1OFL G02 2G1/A0OFL G01 3NC(Vdd)INC(Connect to Vdd) 4POWER DOWNIAC OFF Detect 5ENC VOLUME UPIEncoder VOLUME UP 6RDS CLOCKIRDS clock i
21、nput(TDA7330) 7ENC VOLUME DOWNIEncoder VOLUME DOWN 8REMOCONIRemote signal input. 9PROTECTIONIProtection detecting input. 10SUB ZONE2 LEDOZONE3 LED indicator control 11SUB ZONE1 LEDOZONE2 LED indicator control 1262446 LATCHOElectronic volume control.(M62446 LATCH) 13FUNCTION SW 1 CEOFunction IC contr
22、ol.(TC9274 CE) 14FUNCTION 1/2 DATAOFunction IC control.(TC9274 DATA) 15FUNCTION 1/2 CLOCKOFunction IC control.(TC9274 CLOCK) 16VOLUME,PLL,4094,DATAOLC72131,M62446,KIC9459,TC9184,TC4094(DATA) 17VOLUME,PLL,4094,CLOCKOLC72131,M62446,KIC9459,TC9184,TC4094(CLOCK) 18TUNEDITUNED signal in. 19STEREOISTEREO