《Denon-AVR3310-avr-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《Denon-AVR3310-avr-sm维修电路图 手册.pdf(211页珍藏版)》请在收音机爱好者资料库上搜索。
1、Denon Brand Company, D&M Holdings lnc. e X0425 V.04 DE/CDM 0909 SERVICE MANUAL AV SURROUND RECEIVER AV SURROUND AMPLIFIER MODELJPEUECE2E3E2AE1CEUT AVR-3310CI ? AVR-3310 ? ? AVR-990 ? ? MODELJPEUECE2E3E2AE1CEUT AVC-3310 ? ? s s s Ver. 4 For purposes of improvement, specifications and design are subje
2、ct to change without notice. Please use this service manual with referring to the operating instructions without fail. Some illustrations using in this service manual are slightly different from the actual set. Please refer to the MODIFICATION NOTICE. RadioFans.CN 2 AVR-3310CI/AVR-3310/AVR990/AVC-33
3、10 Please heed the points listed below during servicing and inspection. Heed the cautions! Spots requiring particular attention when servicing, such as the cabinet, parts, chassis, etc., have cautions indicated on labels or seals. Be sure to heed these cautions and the cautions indicated in the hand
4、ling instructions. Caution concerning electric shock! (1) An AC voltage is impressed on this set, so touching in- ternal metal parts when the set is energized could cause electric shock. Take care to avoid electric shock, by for example using an isolating transformer and gloves when servicing while
5、the set is energized, un- plugging the power cord when replacing parts, etc. (2)There are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly! Though great care is taken when manufacturing parts from sheet metal, there may in some
6、rare cases be burrs on the edges of parts which could cause injury if fingers are moved across them. Use gloves to protect your hands. Only use designated parts! The sets parts have specific safety properties (fire resis- tance, voltage resistance, etc.). For replacement parts, be sure to use parts
7、which have the same properties. In par- ticular, for the important safety parts that are marked z on wiring diagrams and parts lists, be sure to use the desig- nated parts. Be sure to mount parts and arrange the wires as they were originally! For safety reasons, some parts use tape, tubes or other i
8、n- sulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wires inside and clamps are used to keep wires away from heating and high voltage parts, so be sure to set everything back as it was originally. Inspect for
9、 safety after servicing! Check that all screws, parts and wires removed or discon- nected for servicing have been put back in their original po- sitions, inspect that no parts around the area that has been serviced have been negatively affected, conduct an insu- lation check on the external metal co
10、nnectors and between the blades of the power plug, and otherwise check that safety is ensured. (Insulation check procedure) Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and turn the power switch on. Us- ing a 500V insulation resistance tester, check that the in-
11、sulation resistance between the terminals of the power plug and the externally exposed metal parts (antenna ter- minal, headphones terminal, microphone terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired. Concerning important safety parts Many of t
12、he electric and structural parts used in the set have special safety properties. In most cases these prop- erties are difficult to distinguish by sight, and using re- placement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will b
13、e preserved. Parts with safety properties are indicated as shown below on the wiring dia- grams and parts lists is this service manual. Be sure to re- place them with parts with the designated part number. (1) Schematic diagrams . Indicated by the z mark. (2) Parts lists . Indicated by the z mark. U
14、sing parts other than the designated parts could result in electric shock, fires or other dangerous situations. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Before returning the unit to the custo
15、mer, make sure you make either (1) a leakage current check or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective. CAUTION CAUTION RadioFans.CN 3 AVR-331
16、0CI/AVR-3310/AVR990/AVC-3310 DIMENSION AVR-3310CI/AVR-3310/AVR-990/AVC-3310 344 434 155 15.5 170.5 20.7 244.5 372.8 20.5 414 54.7 RadioFans.CN 4 AVR-3310CI/AVR-3310/AVR990/AVC-3310 WIRE ARRANGEMENT If wire bundles are untied or moved to perform adjustment or parts replacement etc., be sure to rearra
17、nge them neatly as they were originally bundled or placed afterward. Otherwise, incorrect arrangement can be a cause of noise generation. Wire arrangement viewed from the top Except AVR-3310CI, AVR-990 model sd Front Panel side Back Panel side RadioFans.CN 5 AVR-3310CI/AVR-3310/AVR990/AVC-3310 CAUTI
18、ON IN SERVICING Before the Digital P.W.B. are replaced If you cannot specify the cause of the digital PWB defect, carry out Initializing Update to latest firmware. The defect may be cleared. See the following for the method of initializing the com. Initializing AV SURROUND RECEIVER AV SURROUND RECEI
19、VER initialization should be performed when the com, peripheral parts of com, and Digital P.W.B. are replaced. 1. Switch off the unit. 2. Hold the following STANDARD button and DSP SIMULATION button, and switch on the unit. 3. Check that the entire display is flashing with an interval of about 1 sec
20、ond, and release your fingers from the 2 buttons and the microprocessor will be initialized. Note:If step 3 does not work, start over from step 1. All user settings will be lost and this factory setting will be recovered when this initialization mode. So make sure to memorize your setting for restor
21、ing after the initialization. JIG to use for servicing When you repair the printing board, you can use the following JIG. Please order to Denon Official Service Distributor in your region if necessary. Extention cable kit 00D SPK- 561 EXTENSION UNIT KIT : 1 Set 00D SPK- 562 TUCP CONN. JOINT KIT : 1
22、Set Extention cable for Idling Current Parts Number for Extension Cables and Quantity of Unit. How to use and Adjust Idle Current. 1. The thin and hard plate (ex. Ruler) is fixed with the tape behind the cable. 2. The voltmeter is connected with the other side of the extension cable. 3. Refer to ADJ
23、USTMENT(Idling Current). Parts NumberParts NameQty / unitRemarks 612050082004D6P 250mm NH1L=250mm 6P NH Cable 612050083007D8P 250mm NH1L=250mm 8P NH Cable 1,2 2,3 RadioFans.CN 6 AVR-3310CI/AVR-3310/AVR990/AVC-3310 DISASSEMBLY Disassemble in order of the arrow of the figure of following flow. In the
24、case of the re-assembling, assemble it in order of the reverse of the following flow. In the case of the re-assembling, observe attention of assembling it. TOP COVER DIGITAL UNIT ASSYFRONT PANEL UNIT ASSY Refer to DISASSEMBLYREG UNITRefer to DISASSEMBLY 2. DIGITAL UNIT ASSYRefer to DISASSEMBLY1.FRON
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Denon-AVR3310-avr-sm维修电路图 手册 Denon AVR3310 avr sm 维修 电路图