《Crown-M240-pwr-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《Crown-M240-pwr-sm维修电路图 手册.pdf(581页珍藏版)》请在收音机爱好者资料库上搜索。
1、Service Manual 130352-1 10/02 Rev. D C IECE SERSCE SERIESCE SERIESCE SERIES P O EL U I AE SS IN M L FPROFESSIONAL AUDIO AMPLIFIERS Models: CE-1000, CE-2000 (some units may have the model names: CE-1000A, CE-2000A, CE-2000TX, UT-1010, UT-2020, M120, M240, S2, and S3) 2002 by Crown Audio, Inc., P.O. B
2、ox 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 574-294- 8000. CE Series amplifiers are produced by Crown International, Inc. Trademark Notice: Crown and MultiMode are registered trademarks of Crown International. Other trademarks are the property of their respective owners. RadioFans.CN CE S
3、eries Service ManualRev. D The information furnished in this manual does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. If you need special assistance beyo
4、nd the scope of this manual, please contact the Crown Technical Support Group. Mail: P.O. Box 1000 Elkhart IN 46515-1000 Shipping: 1718 W. Mishawaka Rd., Elkhart IN 46517 Phone: (800) 342-6939/(574) 294-8200 FAX: (574) 294-8301 Web: PRVENIR LE CHOC LECTRIQUE NENLEVEZ PAS LES COUVERTURES. RIEN DES PA
5、RTIES UTILES LINTRIEUR. DBRANCHER LA BORNE AVANT DOUVRIR LA MODULE EN ARRIRE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DISCONNECT POWER CORD BEFORE REMOVING REAR INPUT MODULE TO ACCESS GAIN SWITCH.
6、 CAUTIONAVIS WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE! I RadioFans.CN CE Series Service ManualRev. D Revision History Revision Number DateChanges Rev. A Rev. B Rev. C Rev. D 3-98 2-99 5-99 10-02 II Initial Printing Added Additional Module Documen
7、tation. Added Revision History. Added Inside Cover Page. Updated Cover Page and Table of Contents. Updated Graphic on Page 1-1. Updated Specifications on Page 1-2. Added Section 7, Module and Schematic Information. Added Section 8, Module Parts Lists. Moved existing Module Parts Lists from Section 6
8、 to Section 8. Added Module Parts Lists for Module CPNs:102139-11, 102140-11, 127321-1, 127323-1, 127353-1, 127373-2, 127354-1, and 127354-2. Added Section 9, Field Service Modifications. Added Section 10, Schematics. Moved all existing Schematics from Section 6 to Section 10. Added Schematics 10214
9、1M and 102142M. Updated Cover Page, Revision History and Table of Contents. Revised fan part no. from 125400-3 to 133551-1. Updated phone number area code. Updated sections 1.2, 1.3.6, 7.2, 7.2.1, 7.2.3, 7.3, 7.3.2, 7.3.3, 7.4.1, 9.2, 9.4. Added Module Parts Lists for Module CPNs: 102140-9 revB, 126
10、883-2 rev B, 127321-2, 127323-2, 127353-3, 127354-3, 127451-4 and 127452-4. Added Schematics 127451-4 and 127452-4. Added Assembly Parts List for CE1000A and CE2000A Domestic. Revised Crown logo. Updated Cover Page, Revision History and Table of Contents. RadioFans.CN CE Series Service ManualRev. D
11、This page intentionally left blank III RadioFans.CN CE Series Service ManualRev. D Table of Contents IV 1 Introduction . 1-1 1.1 The CE-Series . 1-1 1.2 Warranty . 1-1 1.3 Specifications . 1-2 1.3.1 Performance . 1-2 1.3.2 Power. 1-2 1.3.3 Controls . 1-2 1.3.4 Indicators. 1-2 1.3.5 Input/Output . 1-
12、2 1.3.6 Connectors . 1-2 1.3.7 Construction . 1-2 2 Maintenance. 2-1 2.1 Surface Mount Technology . 2-1 2.2 Cautions and Warnings. 2-1 2.3 Troubleshooting . 2-1 2.3.1 Pre-AC-Checks. 2-1 2.3.2 Main Module Removal . 2-2 2.3.3 Static Checks . 2-2 2.4 Checkout/Adjustment Procedures . 2-2 2.4.1 Equipment
13、 Required. 2-3 2.4.2 Initial Conditions . 2-3 2.4.3 Test Procedure. 2-3 2.4.4 Service Kit Wire Extensions . 2-3 3 Circuit Theory . 3-1 3.1 Front End Operation. 3-1 3.2 Balanced Gain Stage. 3-1 3.3 Variable Gain Stage . 3-1 3.4 Error Amp. 3-2 3.5 Voltage Amplification . 3-2 3.5.1 Voltage Translator .
14、 3-2 3.5.2 Last Voltage Amplifier. 3-2 3.5.3 Bias Servo . 3-2 3.2.2 Output PCA . 3-3 3.6 Output Topology . 3-2 3.6.1 Pre-Driver . 3-3 3.6.2 Driver . 3-3 3.6.3 Output Devices. 3-3 3.6.4 Flyback Diodes. 3-3 3.6.5 Output Terminating Network. 3-3 3.7 Power Supply. 3-3 3.7.1 Low Voltage Supply. 3-3 3.7.2
15、 Bootstrap Supply. 3-3 3.7.3 High Voltage Supply. 3-4 RadioFans.CN CE Series Service ManualRev. D Table of Contents V 3.8 Protection Circuitry. 3-4 3.8.1 Time Dependent VI Limit . 3-4 3.8.2 Temperature Protection . 3-5 3.8.3 Low-Frequency and Short-Circuited Protection. 3-5 3.8.4 Input Compressor. 3
16、-5 3.8.5 Turn-On Delay. 3-6 3.8.6 Output Relay Muting. 3-6 3.8.7 Input Muting . 3-6 3.8.8 Auxiliary Output Jack . 3-6 3.9 Fan Control Circuitry . 3-6 4 Neutrik Connectors . 4-1 5 Parts . 5-3 5.1 General Information . 5-3 5.2 Standard and Special Parts . 5-3 5.3 Ordering Parts . 5-3 5.4 Shipment. 5-3
17、 5.5 Terms . 5-3 6 Exploded Views, Parts Lists . 6-1 Assy. CE 1000 Domestic. 6-2 Assy. CE 1000 PWA also, a detented rotary level control for each channel. Back Panel: A two-position input sensitivity switch located below the input connectors. Can be set to 1.4 V for full output into an 8-ohm load, o
18、r set to a fixed voltage gain of 26 dB; Some models have an internal jumper located on the Main PWA for setting optional 0.775V sensitivity. A two-position mode switch located below the input connectors. When turned to stereo, the amplifier operates as two independent channels. When in “bridge-mono”
19、 mode the amplifier bridges the two output channels for twice the output voltage. 1.3.4 Indicators A green LED SIGNAL indicator for each channel, which flashes when a very low level signal (40 dBm) is present at input. A red LED CLIP indicator for each channel which turns on when distortion becomes