《AustralianMonitor-AMIS1202P-pwr-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《AustralianMonitor-AMIS1202P-pwr-sm维修电路图 手册.pdf(18页珍藏版)》请在收音机爱好者资料库上搜索。
1、 Australian Monitor 1 Clyde Street, Silverwater NSW 2128 Australia +61 2 9647 1411 .au SERVICE INFORMATION AMIS1202P POWER AMPLIFIER CONTENTS: OPERATION MANUAL SCHEMATIC DIAGRAMS BOARD LAYOUT SERVICE BULLETINS * Over the years there have been a number of revisions to this model RadioFans.CN Clever F
2、eatures, Contractor Friendly AMIS1202P 2 x 120w Power Amplifier Operating Manual AMIS1202P, 2 x 120 Watt Power Amplifier Product Description The AMIS1202P is a dual 120 watt power amplifier designed for commercial installations. The one unit contains two independent 120 watt amplifiers for either st
3、ereo or dual zone applications. The AMIS1202P can be used for either low impedance (4 or 8 ohm) or 70/100v line speaker systems per channel. The amplifier can be mounted in a standard 19” equipment rack (rack ears supplied) or it can be used on a shelf or table. The AMIS1202P features a line level i
4、nput (with parallel output) per channel and is normally used with mixers, mixer amplifiers or other power amplifiers. RadioFans.CN Front Panel Features Power Switch The black rocker switch on the right hand side of the front panel is used to switch the amplifier on and off. The up position is on. Wh
5、en the amplifier is connected to an appropriate AC power source and is switched on, the blue power LED will illuminate. This switch will not switch DC power on or off in DC operation. In DC operation mode, the amplifier is always on and the blue power LED will always be illuminated. On LED The blue
6、“On” LED above the power switch will illuminate when the amplifier is connected to mains power and is switched on. In 24vdc operation the LED will always be on. Signal LED The green “Signal” LEDs located next to the On LED indicate that the AMIS1202P is receiving audio signal via its line level inpu
7、ts. One LED is provided per channel. The signal LEDs are a simple way of trouble-shooting installations especially in multi amplifier projects. At a glance the signal LEDs will indicate that audio is reaching the amplifier. Rack Mounting The AMIS1202P is supplied with rack ears attached to allow mou
8、nting within a standard 19” equipment rack. As is the case with almost all audio products, adequate ventilation and air flow is required. When installing multiple AMIS amplifiers within the one rack, it is recommended that at least one rack unit of ventilation space is left between every two amplifi
9、ers. For table or shelf mounting, the rack ears can be removed using a screwdriver. Once the rack ears are removed, please reinstall the screws. Rear Panel Features AC Power Inlet The operating voltage is 230/240 VAC 50 Hz. The 3 pin IEC power inlet is located on the bottom left of the rear panel an
10、d accepts a standard mains power lead fitted with an IEC connector. Before plugging in a RadioFans.CN power lead, please check the rear panel of the amplifier to ensure that the voltage switch is set correctly for your part of the world. The inlet is equipped with an in-built AC fuse holder fitted w
11、ith an 4 Amp slow blow fuse plus a spare fuse. Please ensure that the mains power cord is disconnected before attempting to check or replace this fuse. Power consumption is 400 VA (max). 230V/240V Slide Switch The operating voltage of the amplifier is user selectable between 230V and 240V via a slid
12、e switch located on the right of the AC inlet. This switch should be set to match the AC voltage of your country 24 Volt DC Power Inlet The AMIS1202P feature optional 24VDC power to run off a battery back-up if required. This is connected via the rear terminal strip. The front panel Power Switch wil
13、l not switch DC power on or off in DC operation. In this mode the amplifier is always on. Speaker Output Terminal Strip Located on the top left of the rear panel are the speaker output terminal strips. A terminal strip is provided for each of the two amplifiers. Reading from left to right, the conne
14、ctions per terminal strip are: COM Common or “-” for low impedance speaker loads (4 or 8 ohms). 4 The “+” for 4 ohm speaker loads (use with common) 8 The “+” for 8 ohm speaker loads (use with common) COM Common or “-” for 70v or 100v speaker loads (maximum load of 80 ohms at 100v) 70 The “+” for 70v
15、 line speaker loads (use with common) 100 The “+” for 100v line speaker loads (use with common) Please ensure that the correct “Common” is used. Low impedance and 70/100v loads can be used simultaneously but please pay careful attention to the overall speaker load. When used individually, the low im
16、pedance load should be 4 ohms or higher while the 100v line load should not fall below 80 ohms per amplifier. When both low impedance and 70/100v outputs are used simultaneously on the one amplifier, ensure that neither output is loaded to maximum. Level Control Located next to the XLR input/output
17、is a recessed screwdriver adjustable level control. One is provided per amplifier channel. The level control is an input attenuation control normally used to match the amplifier to a wide variety of input signals. In essence, the amplifier is designed to receive a 700mv input signal however the leve
18、l control can be used to increase the level for lower signals or decrease the level for higher input signals. In normal use, the level control is used as a set and forget master level control for the amplifier. XLR Audio Input and Parallel Output The AMIS1202P includes both male and female 3 pin XLR
19、 connectors per channel. While the female is normally used as the input to the amplifier, both XLRs are connected in parallel so either will work. When signal is connected to one XLR, the other XLR becomes a line level output allowing the input signal to be distributed (split) to other amplifiers. I
20、n some projects, the same input may be looped through to multiple amplifiers using this method. Up to 6 amplifiers can be looped together without any noticeable loss in level. A distribution amplifier should be used when more than 6 amplifiers need to be looped. The XLRs are wired as follows: Pin 1:
21、 Shield. Pin 2: Hot, +, Positive. Pin 3: Cold, -, Negative RadioFans.CN Fuse Sizes Mains, 230VAC: 4 Amperes Slow Blow. Notes: The DC fuse is located on the circuit board. This is a feature of the AMIS series amplifier, which is equipped with a current limiting circuit preventing excessive DC current
22、, thus eliminating the risk of blowing high tensions fuses. In the unlikely event that the DC fuse actuates, the output transistors should be checked, as it is probable that the amplifier has been subjected to very extreme conditions. Important Safety Information 1. Save the carton and packing mater
23、ial even if the equipment has arrived in good condition. Should you ever need to ship the unit, use only the original factory packing. 2. Read all documentation before operating your equipment. Retain all documentation for future reference. 3. Follow all instructions printed on unit chassis for prop
24、er operation. 4. Do not spill water or other liquids into or on the unit, or operate the unit while standing in liquid. 5. Make sure power outlets conform to the power requirements listed on the back of the unit. 6. Do not use the unit if the electrical power cord is frayed or broken. The power supp
- 配套讲稿: