《AudioAccess-MA361-pwr-sm维修电路图 手册.pdf》由会员分享,可在线阅读,更多相关《AudioAccess-MA361-pwr-sm维修电路图 手册.pdf(108页珍藏版)》请在收音机爱好者资料库上搜索。
1、 AUDIOACCESS MA-361/MA-361CP TWELVE CHANNEL DIGITAL AMPLIFIER PRELIMINARY SERVICE MANUAL Harman Consumer Group 250 Crossways Park Dr. Woodbury, New York 11797 RadioFans.CN FEATURES The Audioaccess MA-361 Twelve Channel Digital Amplifier designed, engineered and manufactured by Madrigal in Middletown
2、, CT represents the product of over two years of research and development. As the inventor of the 12 channel amplifier category, Audioaccess has reinvented this category with the introduction of the MA-361. The goals for the MA-361 were clear: high power, low distortion, quiet, cool operation, outst
3、anding sonics and ease of installation, when used not only in Audioaccess systems, but also with other home and commercial audio distribution systems. The trend towards higher quality and larger speakers for custom installed applications has created a need for this amp. We believe you will agree tha
4、t the MA-361 is the first in an entirely new class of twelve channel amplifiers. Unique features The main features of the MA-361 include a conservative power rating of 100 Watts per channel into 8 Ohms from 20Hz- 20kHz with all channels driven at 93% efficiency. This amazing efficiency not only mini
5、mizes power consumption, it also runs surprisingly cool. Other unique features include programmable 7-band graphic EQ (set by the installer via PC) for each zone and optional plug-in stereo Volume/Tone Control Modules, which pro-vide volume control in Expansion rooms/sub zones within an Audioaccess
6、system or another RS-232 based control system. The modular layout permits the dealer to easily replace individual amplifier modules should service ever be required. An external speaker termination board can be ordered in advance to allow termination of loudspeakers before the amplifier is delivered
7、for final installation. At final, simply plug the speaker termination board onto the rear panel of the amplifier. Other features To make the amplifier specifically attractive for use in whole-house audio distribution, we have included specific features to ensure reliable and easy installation. Signa
8、l sensing and voltage triggers activate the main power in each stereo zone of amplification. Dip switches on the rear-panel configure the MA-361 for use in either mono or stereo operation. A simple bussing scheme allows audio signals to be routed into a single zone, selected zones, or all areas. 7-B
9、and Graphic Equalization The MA-361s 7-band graphic equalization capabilities allows the installing dealer to custom tailor the sound in each zone to compensate for the different room acoustics throughout a residence, maximizing the performance of each pair of speakers. This is accomplished by using
10、 the Audioaccess Installation Manager Software application (or stand-alone application) running on the dealers PC or laptop. Signal Sensing and Voltage Triggers The signal sensing capabilities of the MA-361 ensure that the amplifiers for a given zone are only powered on when a particular area is act
11、ive, saving on energy consumption. Voltage triggers allow the MA-361 to automatically turn on accessory items such as a fan, or a separate device when either the amplifier or a designated zone is activated. Volume/Tone Control Modules Optional Volume/Tone Control Modules, which plug into available s
12、lots inside the amplifier, provide the ability to supply high power at very low distortion levels to expansion rooms within the multi-room system. The user may control the volume in rooms with Audioaccess keypads and touchscreens, or by using ANY other touch screen/control systems. A total of 6 Volu
13、me/Tone Control Modules may be installed in the MA-361. Flexible Installation Capabilities The MA-361 is designed for use with Audioaccess systems, as well as other Multi-room or RS-232 based systems. The unit is programmed with the proprietary Installation Manager application when it is used with o
14、ther Audioaccess Multi- Room components. Configuration settings are downloaded from a Windows PC or laptop via the RS-485 communication port on the MA-361. When used with other RS-232 based systems, a separate application is available, which downloads amplifier configuration settings via the RS-232
15、port on the MA-361CP version. Summary The MA-361s combination of power capabilities, sonic quality, features, programming ease, installation flexibility and serviceability clearly sets the new standard for amplifiers within the multi-room category. RadioFans.CN Specifications: Number of Channels: 12
16、, configured as 6 left/right mono or stereo pairs (zones) Power Output: 100 Watts 8 ohms, from 20Hz 20kHz, all channels driven 130 Watts 4 ohms, from 20Hz 20kHz, all channels driven 200 Watts 4 ohms, from 20Hz 20kHz, two channels driven Efficiency: 93% 100 Watts/8 ohms THD the byte-wide (x8) data ap
17、pears on DQ7-DQ0. This device is designed to be programmed in-system using only a single 3.0 volt VCC supply. No VPP is required for write or erase operations. The device can also be programmed in standard EPROM programmers. This device is manufactured using AMDs 0.32 m process technology, and offer
18、s all the features and ben- efits of the Am29LV200, which was manufactured using 0.5 m process technology. In addition, the Am29LV200B features unlock bypass programming and in-system sector protection/unprotection. The standard device offers access times of 55, 70, 90 and 120 ns, allowing high spee
19、d microprocessors to operate without wait states. To eliminate bus contention the device has separate chip enable (CE#), write enable (WE#) and output enable (OE#) controls. The device requires only a single 3.0 volt power supply for both read and write functions. Internally generated and regulated
20、voltages are provided for the program and erase operations. The device is entirely command set compatible with the JEDEC single-power-supply Flash standard. Com- mands are written to the command register using standard microprocessor write timings. Register con- tents serve as input to an internal s
21、tate-machine that controls the erase and programming circuitry. Write cycles also internally latch addresses and data needed for the programming and erase operations. Reading data out of the device is similar to reading from other Flash or EPROM devices. Device programming occurs by executing the pr
22、ogram command sequence. This initiates the Embedded Program algorithman internal algorithm that auto- matically times the program pulse widths and verifies proper cell margin. The Unlock Bypass mode facili- tates faster programming times by requiring only two write cycles to program data instead of
23、four. Device erasure occurs by executing the erase command sequence. This initiates the Embedded Erase algorithman internal algorithm that automatically preprograms the array (if it is not already programmed) before executing the erase operation. During erase, the device automatically times the eras
24、e pulse widths and verifies proper cell margin. The host system can detect whether a program or erase operation is complete by observing the RY/BY# pin, or by reading the DQ7 (Data# Polling) and DQ6 (toggle) status bits. After a program or erase cycle has been completed, the device is ready to read