1、SERVICE MANUAL IMPORTANT NOTICE This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the users, and
2、have therefore not been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA product ow
3、ners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any individual of firm does not constitute authorization, certification or recognition of any applicable technical capabil
4、ities, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, ther
5、efore, inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may ha
6、ve accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. 100654 AV RECEIVER RX-V595/R-V905/ RX-V595RDS TO SERVICE PERSO
7、NNEL . 1 REMOTE CONTROL PANELS. 1 FRONT PANELS. 2 REAR PANELS . 34 SPECIFICATIONS.56 INTERNAL VIEW . 7 DISASSEMBLY PROCEDURES . 7 SELF DIAGNOSIS FUNCTION . 819 FACTORY PRESET . 20 AMP ADJUSTMENT . 21 nCONTENTS TUNER ADJUSTMENT.2225 IC DATA . 2635 DISPLAY DATA . 36 BLOCK DIAGRAM. 3739 PRINTED CIRCUIT
8、 BOARD . 4055 SCHEMATIC DIAGRAM .5663 PARTS LIST .6479 PRINTED CIRCUIT BOARD . 8081 REMOTE CONTROL TRANSMITTER . 82 This Service Manual uses recycled paper. 1 RX-V595/R-V905/RX-V595RDS I TO SERVICE PERSONNEL 1. Critical Components information. Components having special characteristics are marked and
9、 must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Model only). When service has been completed, it is imperative that you verify that all exposed conductive surfaces are properly insulated from supply circuits. Meter impe
10、dance should be equivalent to 1500 ohm shunted by 0.15F. Leakage current must not exceed 0.5mA. Be sure to test for leakage with the AC plug in both polarities. WARNING: CHEMICAL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other electrical/electronic
11、 and/or plastic (where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR
12、 MOUTH FOR ANY REASON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components located inside the enclosure of this product, wash your hands before h
13、andling food. I REMOTE CONTROL PANELS M U,C,R,T and L modelsM A,B and G models WALL OUTLET EQUIPMENT UNDER TEST AC LEAKAGE TESTER OR EQUIVALENT INSULATING TABLE CAUTION F804: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE,REPLACE ONLY WITH SAME TYPE 8.0A, 250V FUSE. CAUTION F804: REPLACE WITH SAME TY
14、PE 8.0A, 250V FUSE. ATTENTION F804: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 8.0A, 250V FUSE. A V 2 RX-V595/R-V905/RX-V595RDS M RX-V595 (U, C, R, T, A and L models) M R-V905 (U, C, R, T and A models) M RX-V595RDS (B and G models) I FRONT PANELS 3 RX-V595/R-V905/RX-V595RDS M RX-V595/R-V905 U m
15、odel M RX-V595/R-V905 C model I REAR PANELS M RX-V595/R-V905 R model M RX-V595/R-V905 T model 4 RX-V595/R-V905/RX-V595RDS MRX-V595RDS B model MRX-V595RDS G model M RX-V595 L model M RX-V595/R-V905 A model 5 RX-V595/R-V905/RX-V595RDS IFM SECTION Tuning Range U, C models87.50 to 107.9MHz R, T models (
16、Frequency Step: 100kHz) 87.50 to 108.0MHz (Frequency Step: 50kHz) 87.50 to 108.0MHz A, B, G, L models87.50 to 108.00MHz 50dB Quieting Sensitivity (IHF) U, C, R, T models only Mono, 1kHz, 100% mod1.6V(15.3dBf) Stereo, 1kHz, 100% mod23V(38.5dBf) Usable Sensitivity (DIN) A, B, G, L models only DIN, Mon
17、o(S/N 26dB)0.9V DIN, Stereo(S/N 46dB)28V Alternate Channel Selectivity U, C, R, T models (400kHz)75dB A, B, G, L models (300kHz) Selectivity(two signals, 40kHz Dev.)55dB Signal-to-Noise Ratio U, C, R, T models (IHF) Mono/Stereo81dB/75dB A, B, G, L models (DIN-Weighted, 40kHz Dev.) Mono/Stereo75dB/69
18、dB Harmonic Distortion (1kHz) Mono/Stereo0.1%/0.2% Stereo Separation (1kHz)48dB Frequency Response (20Hz to 15kHz)01dB Output Level (1kHz) U, C, R, T models (100% mod.)550mV A, B, G, L models (40kHz Dev.)550mV Antenna Input75 unbalanced I SPECIFICATIONS IAUDIO SECTION Minimum RMS Output Power Per Ch
19、annel (Power Amp. Section) U, C models MAIN L/R, REAR L/R 20Hz to 20kHz, 0.04% THD, 870W+70W 1kHz, 0.07% THD, 885W+85W CENTER 20Hz to 20kHz, 0.04% THD, 870W 1kHz, 0.07% THD, 885W R,T,A,B,G,L models MAIN L/R, REAR L/R 20Hz to 20kHz, 0.04% THD, 865W+65W 1kHz, 0.07% THD, 880W+80W CENTER 20Hz to 20kHz,
20、0.04% THD, 865W 1kHz, 0.07% THD, 880W Maximum Power (EIAJ) R, T models only MAIN L/R, REAR L/R 1kHz, 10% THD, 8105W+105W CENTER, 1kHz, 10% THD, 8105W Dynamic Power Per Channel (IHF) MAIN L/R U, C models 8/6/4/2 100W+100W/120W+120W/145W+145W/170W+170W R,T,A,B,G,L models 8/6/4/2 90W+90W/110W+110W/135W
21、+135W/160W+160W DIN Standard Output Power Per Channel G model only MAIN L/R, 1kHz, 0.7% THD, 4110W+110W Dynamic Headroom(8) U, C models only1.55dB IEC Power G model only MAIN L/R, 1kHz, 0.04% THD, 875W+75W Power Band Width MAIN L/R, 0.1% THD, 35W, 810Hz to 50kHz Damping Factor (SPEAKER A) MAIN L/R,
22、20Hz to 20kHz, 860 Input Sensitivity/Input Impedance PHONO (MM)2.5mV/47k CD etc.150mV/47k MAIN L/R (EXTERNAL DECODER)150mV/47k CENTER150mV/40k SURROUND L/R150mV/40k SUB WOOFER150mV/40k Maximum Input Signal Level (1kHz) PHONO (MM), 0.1% THD110mV CD etc. (EFFECT ON), 0.5% THD2.2V Output Level/Output I
23、mpedance REC OUT150mV/1.2k SUB WOOFER (MAIN SP : SMALL)2.1V/1.2K B,G models only PRE OUT4V/1.2K Headphone Jack Rated Output/Impedance CD etc., Input=1kHz, 150mV, RL=80.5V/390 Frequency Response(20Hz to 20kHz) CD etc., MAIN00.5dB RIAA Equalization Deviation PHONO (MM)00.5dB Total Harmonic Distortion(