Yamaha-RXV-500-D-Service-Manual电路原理图.pdf
《Yamaha-RXV-500-D-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-RXV-500-D-Service-Manual电路原理图.pdf(147页珍藏版)》请在收音机爱好者资料库上搜索。
1、P.O.Box 1, Hamamatsu, Japan 101 2 6 5 SERVICE MANUAL AV RECEIVER CONTENTS TO SERVICE PERSONNEL .2 FRONT PANELS .3 REAR PANELS .49 REMOTE CONTROL PANELS .10 SPECIFICATIONS / 参考仕様 . 1116 INTERNAL VIEW .17 SERVICE PRECAUTIONS / 時注意事項 .17 DISASSEMBLY PROCEDURES / 分解手順 .1821 UPDATING FIRMWARE / .2223 SEL
2、F-DIAGNOSTIC FUNCTION / (自己診断機能) .2458 POWER AMPLIFIER ADJUSTMENT / 調整 .59 DISPLAY DATA .6061 IC DATA .6282 PIN CONNECTION DIAGRAMS .83 BLOCK DIAGRAMS .8485 WIRING DIAGRAMS .8687 PRINTED CIRCUIT BOARDS .88102 SCHEMATIC DIAGRAMS .103113 REPLACEMENT PARTS LIST . 115129 REMOTE CONTROL .130132 CONFIGURI
3、NG THE SYSTEM SETTINGS .133 設定変更 .134 FIRMWARE UPDATING PROCEDURE .135140 更新手順 .141146 RX-V475/HTR-4066/ RX-V500D Copyright (c) Yamaha Corporation All rights reserved. This manual is copyrighted by Yamaha and may not be copied or redistributed either in print or electronically without permission. 13
4、.03 IMPORTANT NOTICE This manual has been provided for the use of authorized Yamaha Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifi cally Yamaha Products, are already known and understood by the users, and have there
5、fore not been restated. WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specifi ed. For these reasons, we advise all Yamaha product owners tha
6、t any service required should be performed by an authorized Yamaha Retailer or the appointed service representative. IMPORTANT: The presentation or sale of this manual to any individual or fi rm does not constitute authorization, certifi cation or recognition of any applicable technical capabilities
7、, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of Yamaha are continually striving to improve Yamaha products. Modifi cations are, therefor
8、e, inevitable and specifi cations are subject to change without notice or obligation to retrofi t. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may hav
9、e accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. RX-V475/HTR-4066 models Note: When the DIGITAL P.C.B. or IC22
10、on DIGITAL P.C.B. is replaced, this unit will display “Internal Error” and will not operate properly. The model name MUST be written to the backup IC (EEPROM: IC22 on DIGITAL P.C.B.) to have proper operation. (For details, refer to “S5. SOFT SWITCH” menu of the self-diagnostic function.) 注意: DIGITAL
11、 P.C.B. DIGITAL P.C.B. IC22 交換、“Internal Error” 表示本機正常動作 。正常動作、名 IC(EEPROM:DIGITAL P.C.B. IC22)書込 必要。 (詳細、 “S5. SOFT SWITCH” 参照。 ) RX-V475/HTR-4066/ RX-V500D This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm. DO NOT PLACE SO
12、LDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components located insid
13、e the enclosure of this product, wash your hands before handling food. 1. Critical Components Information Components having special characteristics are marked and must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Models On
14、ly) When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. Meter impedance should be equivalent to 1500 ohms shunted by 0.15 F. TO SERVICE PERSONNEL Leakage current must not exceed 0.5mA. Be sure to test for leaka
15、ge with the AC plug in both polarities. WARNING: CHEMICAL CONTENT NOTICE! For U model “CAUTION” “F5401: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 2A, 250V FUSE.” “F5402: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 6A, 125V FUSE.” For C
16、model CAUTION F5401: REPLACE WITH SAME TYPE 2A, 250V FUSE. F5402: REPLACE WITH SAME TYPE 6A, 125V FUSE. ATTENTION F5401: UTILISER UN FUSIBLE DE RECHANGE DE MME TYPE DE 2A, 250V. F5402: UTILISER UN FUSIBLE DE RECHANGE DE MME TYPE DE 6A, 125V. WALL OUTLET EQUIPMENT UNDER TEST AC LEAKAGE TESTER OR EQUI
17、VALENT INSULATING TABLE 本機搭載基板付 接合部無鉛付。 無鉛種類、修理時 下記無鉛使用推奨。 Sn+Ag+Cu(錫 + 銀 + 銅) Sn+Cu(錫 + 銅) Sn+Zn+Bi(錫 + 亜鉛 + ) 注意: 無鉛融点温度通常鉛入比 30 40程度高、 合 使用。 All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder. Among some types of lead free solder currently availabl