Yamaha-RXSL-100-RDS-Service-Manual电路原理图.pdf
《Yamaha-RXSL-100-RDS-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-RXSL-100-RDS-Service-Manual电路原理图.pdf(82页珍藏版)》请在收音机爱好者资料库上搜索。
1、I CONTENTS TO SERVICE PERSONNEL . 2 FRONT PANELS. 4 REAR PANELS . 56 REMOTE CONTROL PANELS. 6 SPECIFICATIONS. 710 INTERNAL VIEW . 10 DISASSEMBLY PROCEDURES / 分解手順. 1113 SELF DIAGNOSIS FUNCTION (DIAG) / 自己診断機能(). 1435 D-AMP MODULE TROUBLESHOOTING / -故障診断. 35 AMP ADJUSTMENT / 部調整.36 DISPLAY DATA . 37
2、IC DATA . 3843 BLOCK DIAGRAM. 4445 PIN CONNECTION DIAGRAM . 46 PRINTED CIRCUIT BOARD . 4757 SCHEMATIC DIAGRAM . 5965 PARTS LIST. 6781 REMOTE CONTROL. 8283 100876 P.O.Box 1, Hamamatsu, Japan SERVICE MANUAL AV RECEIVER/AV AMPLIFIER RX-SL100/RX-SL100RDS RX-SL100/RX-SL100RDS IMPORTANT NOTICE This manual
3、 has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and understood by the users, and have therefore not been restated. WARNING:F
4、ailure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we advise all YAMAHA product owners that any service required should be pe
5、rformed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or recognition of any applicable technical capabilities, or establish a principle-agent relat
6、ionship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, therefore, inevitable and specifications are su
7、bject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by grounding yourself to the
8、 ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. 2 RX-SL100/RX-SL100RDS RX-SL100/RX-SL100RDS WALL OUTLET EQUIPMENT UNDER TEST AC LEAKAGE TESTER OR EQUIVAL
9、ENT INSULATING TABLE I TO SERVICE PERSONNEL 1. Critical Components Information Components having special characteristics are marked s and must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For 120V Models Only) When service has been
10、 completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. GMeter impedance should be equivalent to 1500 ohm shunted by 0.15F. GLeakage current must not exceed 0.5mA. GBe sure to test for leakage with the AC plug in both polarities. WARNI
11、NG: CHEMICAL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other electrical/electronic and/or plastic (where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to
12、cause cancer and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA- SON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to so
13、lder/flux vapor! If you come in contact with solder or components located inside the enclosure of this product, wash your hands before handling food. “CAUTION” “F1: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 5A, 125V FUSE.” CAUTION F1: REPLACE WITH SAME TYPE 5A, 125V
14、FUSE. ATTENTION F1: UTILISER UN FUSIBLE DE RECHANGE DE MEME TYPE DE 5A, 125V. 3 RX-SL100/RX-SL100RDS RX-SL100/RX-SL100RDS 本機搭載基板付使用 下記通。 The P.C.B.s installed in this unit are soldered using the following solder. About Lead Free Solder / 無鉛 無鉛種類、修理時下記 無鉛使用推奨。 Sn+Ag+Cu (錫+銀+銅) Sn+Cu (錫+銅) Sn+Zn+Bi (錫
15、+亜鉛+) 注意: 無鉛融点温度通常鉛入比3040 程度高、合 使用。 鉛入使得場合、交換 部品端子部周辺部無鉛取除、 無鉛鉛入十分溶状態 付。 Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair work. Sn + Ag + Cu (tin + silver + copper) Sn + Cu (tin + copper) Sn + Zn + Bi (tin + zinc + bismuth)
16、Caution: 1. As the melting point temperature of the lead free solder is about 30C to 40C (50F to 70F) higher than that of the lead solder, be sure to use a soldering iron suitable to each solder. 2. If lead solder must be used, be sure to remove lead free solder from each terminal section of the par
17、ts to be replaced and from the area around it completely before soldering, or make sure that the lead free solder and lead solder melt together fully. Component Side / 部品面Foil Side / 面 DIGITAL P.C.B.Lead Solder / 鉛入Lead Solder / 鉛入 INPUT P.C.B.Lead Free Solder / 無鉛 MAIN P.C.B.Lead Solder / 鉛入Lead Fr
18、ee Solder / 無鉛 POWER P.C.B.Lead Free Solder / 無鉛 I IMPEDANCE SELECTOR (B, G models only) IMPEDANCE SELECTOR WARNING: Do not change the IMPEDANCE SELECTOR switch setting while the power to this unit is on, otherwise this unit may be damaged. 4 RX-SL100/RX-SL100RDS RX-SL100/RX-SL100RDS I FRONT PANELS
19、RX-SL100 (U, C, A, L, R, T, K models) RX-SL100 (J model) RX-SL100RDS (B, G models) 5 RX-SL100/RX-SL100RDS RX-SL100/RX-SL100RDS RX-SL100 (L model) RX-SL100 (R model) RX-SL100 (T model) RX-SL100 (K model) I REAR PANELS RX-SL100 (U, C models) RX-SL100 (A model) 6 RX-SL100/RX-SL100RDS RX-SL100/RX-SL100R
20、DS I REMOTE CONTROL PANELS RX-SL100RX-SL100RDS RX-SL100 (J model) RX-SL100RDS (B, G models) 7 RX-SL100/RX-SL100RDS RX-SL100/RX-SL100RDS I Audio Section / 部 Minimum RMS Output Power (Power Amp. Section) / 定格出力 (部) (1 kHz) FRONT L/R U, C models (0.9% THD, 6 ohms) .(FTC) 65W + 65W A, B, G, L, R, T, K,
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yamaha RXSL 100 RDS Service Manual 电路 原理图