Yamaha-NSBP-400-Service-Manual电路原理图.pdf
《Yamaha-NSBP-400-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-NSBP-400-Service-Manual电路原理图.pdf(71页珍藏版)》请在收音机爱好者资料库上搜索。
1、R-1330/NS-BP400 The MCS-1330 consists of the R-1330, CD-1330 and NS-BP400. This service manual is for the R-1330/NS-BP400. For service manual of the CD-1330, please refer to the following publication number: MCS-1330 、R-1330、CD-1330 NS-BP400 構成。 R-1330/NS-BP400 用。 CD-1330 用下記管理参照。 1 0 11 2 7 SERVICE
2、 MANUAL IMPORTANT NOTICE This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifi cally YAMAHA Products, are already known and understood by the users, and have t
3、herefore not been restated. WARNING: Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specifi ed. For these reasons, we advise all YAMAHA product owners
4、 that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT: The presentation or sale of this manual to any individual or fi rm does not constitute authorization, certifi cation or recognition of any applicable technical capabili
5、ties, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA products. Modifications are, there
6、fore, inevitable and specifi cations are subject to change without notice or obligation to retrofi t. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING: Static discharges can destroy expensive components. Discharge any static electricity your body may
7、have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT: Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. CONTENTS TO SERVICE PERSONNEL .24 PREVENTION OF ELECTROSTAT
8、IC DISCHARGE .5 SYSTEM COMPOSITION / 構成 .6 FRONT PANELS .6 REAR PANELS .78 REMOTE CONTROL PANELS .78 SPECIFICATIONS / 参考仕様 .9 INTERNAL VIEW .10 DISASSEMBLY PROCEDURES / 分解手順 . 1113 TEST MODE / .1415 UPDATING FIRMWARE / 書込 .1620 DISPLAY DATA .21 IC DATA .2227 PIN CONNECTION DIAGRAMS .2829 BLOCK DIAGR
9、AM .31 PRINTED CIRCUIT BOARDS .3238 SCHEMATIC DIAGRAMS .3941 REPLACEMENT PARTS LIST .4353 REMOTE CONTROL .54 animate 08.12 P.O.Box 1, Hamamatsu, Japan Copyright 2008 All rights reserved. This manual is copyrighted by YAMAHA and may not be copied or redistributed either in print or electronically wit
10、hout permission. R-1330/NS-BP400 RECEIVER/SPEAKERS MICRO COMPONENT SYSTEMMCS-1330 CD-1330: 101130 CD-1330: 101130 RadioFans.CN 收音机爱 好者资料库 2 R-1330/NS-BP400 R-1330/NS-BP400 This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm. D
11、O NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components
12、 located inside the enclosure of this product, wash your hands before handling food. 1. Critical Components Information Components having special characteristics are marked and must be replaced with parts having specifications equal to those originally installed. 2. Leakage Current Measurement (For
13、120V Models Only) When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. Meter impedance should be equivalent to 1500 ohms shunted by 0.15 F. For U model “CAUTION” “F1: FOR CONTINUED PROTECTION AGAINST RISK OF FIR
14、E, REPLACE ONLY WITH SAME TYPE 5A, 125V FUSE.” For C model CAUTION F1: REPLACE WITH SAME TYPE 5A, 125V FUSE. ATTENTION F1: UTILISER UN FUSIBLE DE RECHANGE DE MME TYPE DE 5A, 125V. 本機搭載基板付 接合部無鉛付。 無鉛種類、修理時 下記無鉛使用推奨。 Sn+Ag+Cu(錫 + 銀 + 銅) Sn+Cu(錫 + 銅) Sn+Zn+Bi(錫 + 亜鉛 + ) 注意: 無鉛融点温度通常鉛入比 30 40程度高、 合 使用。
15、All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder. Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair work. Sn + Ag + Cu (tin + silver + copper) Sn + Cu (tin + copper) Sn + Zn
16、+ Bi (tin + zinc + bismuth) Caution: As the melting point temperature of the lead free solder is about 30C to 40C (50F to 70F) higher than that of the lead solder, be sure to use a soldering iron suitable to each solder. TO SERVICE PERSONNEL Leakage current must not exceed 0.5mA. Be sure to test for
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yamaha NSBP 400 Service Manual 电路 原理图