Yamaha-AX-596-Service-Manual电路原理图.pdf
《Yamaha-AX-596-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Yamaha-AX-596-Service-Manual电路原理图.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、AX-596 SERVICE MANUAL STEREO AMPLIFIER AX-596 100717 I CONTENTS SPECIFICATIONS. 1 TO SERVICE PERSONNEL . 2 IMPEDANCE SELECTOR . 2 REAR PANELS . 3 INTERNAL VIEW . 5 DISASSEMBLY PROCEDURES . 5 ADJUSTMENTS . 6 BLOCK DIAGRAM. 6 -COM DATA . 7 PRINTED CIRCUIT BOARD . 815 SCHEMATIC DIAGRAM . 1617 PARTS LIS
2、T . 1827 REMOTE CONTROL TRANSMITTER . 28 IMPORTANT NOTICE This manual has been provided for the use of authorized YAMAHA Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically YAMAHA Products, are already known and und
3、erstood by the users, and have therefore not been restated. WARNING:Failure to follow appropriate service and safety procedures when servicing this product may result in personal injury, destruction of expensive components, and failure of the product to perform as specified. For these reasons, we ad
4、vise all YAMAHA product owners that any service required should be performed by an authorized YAMAHA Retailer or the appointed service representative. IMPORTANT:The presentation or sale of this manual to any individual or firm does not constitute authorization, certification or recognition of any ap
5、plicable technical capabilities, or establish a principle-agent relationship of any form. The data provided is believed to be accurate and applicable to the unit(s) indicated on the cover. The research, engineering, and service departments of YAMAHA are continually striving to improve YAMAHA product
6、s. Modifications are, therefore, inevitable and specifications are subject to change without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING:Static discharges can destroy expensive components. Discharge any static el
7、ectricity your body may have accumulated by grounding yourself to the ground buss in the unit (heavy gauge black wires connect to this buss). IMPORTANT:Turn the unit OFF during disassembly and part replacement. Recheck all work before you apply power to the unit. AX-596 RadioFans.CN 收音机爱 好者资料库 AX-59
8、6 1 I SPECIFICATIONS I Power Section Minimum RMS Output Power 8, 20Hz to 20kHz, 0.015% THD100W + 100W Maximum Output Power (EIAJ) 1kHz, 10% THD 8/6145W / 170W Dynamic Power (IHF) 8/6/4/2140/170/220/290W DIN Standard Output Power 4, 1kHz, 0.7% THD150W IEC Output Power 8, 1kHz, 0.015% THD110W Power Ba
9、nd Width 8, 50W, 0.03% THD10Hz to 50kHz Damping Factor 8, 20Hz to 20kHz320 Frequency Response 20Hz to 20kHz0 0.5dB 20Hz to 100kHz0 +0.5, 3dB Total Harmonic Distortion (20Hz to 20kHz) CD/DVD to SP OUT (8, 50W)0.008% Signal to Noise Ratio (IHF-A-Network) CD/DVD (Input Shorted, CD/DVD DIRECT AMP ON) 11
10、0dB PHONO (Input Shorted)92dB Residual Noise (IHF-A-Network) CD/DVD DIRECT AMP ON35V I Control Section Input Sensitivity / Impedance CD/DVD etc.150mV / 47k PHONO2.5mV / 47k Output Level / Impedance PRE OUT1V / 1.2k REC OUT150mV / 0.6k Headphone Jack Rated Output / Impedance 0.33V / 680 Channel Separ
11、ation CD/DVD (Input 5.1k Terminated) 1kHz/10kHz65 / 50dB Tone Control Characteristics BASS10dB (20Hz) TREBLE10dB (20kHz) Continuous Loudness Control Attenuation30dB (1kHz) I General Power Supply U, C modelsAC120V, 60Hz B, G modelsAC230V, 50Hz A modelAC240V, 50Hz R, T modelsAC110/120/220/240V, 50/60H
12、z Power Consumption Approx. 220W AC Outlets 3 switched outlets U, C, G, R, T models100W max, total 1 switched outlets A, B models100W max, total Dimensions (W x H x D)435 x 151 x 396mm (17-1/8 x 5-15/16 x 15-9/16) Weight 11.0 kg (23lbs. 5oz.) Accessories Remote Control Transmitter Batteries Color Go
13、ld / Black / Titan * Specifications subject to change without notice. U . U.S.A. modelC . Canada model G. European modelB . British model A . Australia modelT . China model R . General model DIMENSIONS RadioFans.CN 收音机爱 好者资料库 AX-596 2 WARNING: CHEMICAL CONTENT NOTICE! The solder used in the producti
14、on of this product contains LEAD. In addition, other electrical/electronic and /or plastic (where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive har
15、m. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA- SON WHATSOEVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or comp
16、onents located inside the enclosure of this product, wash your hands before handling food. I TO SERVICE PERSONNEL 1. Critical Components Information Components having special characteristics are marked s and must be replaced with parts having specifications equal to those originally installed. 2. Le
17、akage Current Measurement (For 120V Models Only) When service has been completed, it is imperative to verify that all exposed conductive surfaces are properly insulated from supply circuits. GMeter impedance should be equivalent to 1500 ohm shunted by 0.15F. GLeakage current must not exceed 0.5mA. G
18、Be sure to test for leakage with the AC plug in both polarities. I IMPEDANCE SELECTOR AX-596 3 I REAR PANELS R model U model C model A model AX-596 4 B model G model T model J model AX-596 5 I DISASSEMBLY PROCEDURES (Remove parts in the order as numbered.) Disconnect the power cord from the AC outle
19、t. 1. Removal of Top Cover a. Remove 6 screws (1) in Fig. 1. 2. Removal of Front Panel a. Remove 6 screws (2) in Fig. 1. 3. Removal of Sub Chassis a. Remove 4 plastic rivets (3) in Fig. 1, then remove the Side Plates. b. Remove 5 screws (4) in Fig. 1. 4. Removal of Power Transformer a. Remove 4 scre
20、ws (5) in Fig. 1. b. Remove 4 screws (6) in Fig. 1. 5. Checking and Parts Replacement of MAIN P.C.B. (1) a. Remove 2 plastic rivets (7) in Fig. 1. b. Remove 12 screws (8) in Fig. 1, then remove the MAIN P.C.B. (1) with Heat Sink. Fig. 1 I INTERNAL VIEW 1 MAIN P.C.B. (9) 2 MAIN P.C.B. (2) 3 MAIN P.C.
21、B. (1) 4 MAIN P.C.B. (5) 5 FUNCTION P.C.B. (13) 6 FUNCTION P.C.B. (4) 7 FUNCTION P.C.B. (5) 8 MAIN P.C.B. (10) 9 MAIN P.C.B. (11) 0 FUNCTION P.C.B. (7) A FUNCTION P.C.B. (6) B FUNCTION P.C.B. (3) C FUNCTION P.C.B. (1) AX-596 6 I ADJUSTMENTS Confirmation of Idling Current Right after Power is switche
22、d ON, confirm the voltages measured at R111, R135 (L ch) and R112, R136 (R ch) are between 0.4mV to 8.0mV. If it exceeds 8.0mV, open (cut off) R175 (L ch), R176 (R ch) and reconfirm the voltage. I BLOCK DIAGRAM AX-596 7 I -COM DATA IC308 : M34748E8SP ABCDEFGHIJ 1 2 3 4 5 6 7 AX-596 To MAIN (5) To/Fr
23、om FUNCTION (1) SPEAKERS B IMPEDANCE SELECTOR WH From MAIN (9)From MAIN (2) WH WH OROR POW +12S E BL BEBE BL MU S12 GND GND RYSP RYPS PRPS PRI PRO VRP VRG RE BE P. C. B. MAIN (1) P. C. B. MAIN (7) From FUNCTION (1) -15 15 E E L E R E From FUNCTION (7) HL E HR LB A B 9 I PRINTED CIRCUIT BOARD (Foil s