1、RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 1.913.101-.108/.321-.324/.605-.610 Date printed: 12.06.2002 10.27.1481 (0602) VU/PPM Meters 1 VU/PPM LED Level Meter Modules Contents 1 General.2 2 Functional Description.3 3 Technical Specifications.3 4 Block Diagram .4 5 Alignment.4 Diagrams PCB No.
2、Diagram Component Layout Parts List VU/PPM 30 LED with GRM 1.913.293.00 1.913.293.00 VU/PPM 30 LED 1.913.294.00 1.913.293.00 1.913.293.00 1.913.294.00 LED PPM Meter (10 LED) 1.913.291.00 1.913.291.00 1.913.291.00 1.913.291.00 Scope of Validity These instructions apply to the following assemblies: Di
3、splay 1 Channel, dark front panel 2 Channels, dark front panel 2 Channels, bright front panel 4 Channels, dark front panel PCB No. PPM 1.913.101 1.913.105 1.913.605 1.913.321 1.913.294 VU 1.913.102 1.913.106 1.913.606 1.913.322 1.913.294 PPM w. GRM 1.913.103 1.913.107 - 1.913.323 1.913.293 VU w. GRM
4、 1.913.104 1.913.108 - 1.913.324 1.913.293 PPM w. additional small level meter - - 1.913.610 - 1.913.294, 1.913.291 1.913.101-.108/.321-.324/.605-.610 2 VU/PPM Meters 10.27.1481 (0602) Date printed: 12.06.2002 1 General The Level Meter units with 30 LEDs have been developed for installation in the d
5、isplay panel of Studer Mixing Consoles. Instruments with VU (vol- ume unit) and PPM (peak program meter) characteristics, with or without gain reduction meter (GRM) are available. Instead of bar-graph indication, also dot indication is optionally available. The instruments listed below are equipped
6、with the PCBs 1.913.294 (VU or PPM) or 1.913.293 (VU or PPM with gain reduction meter) according to the table above. Please consult the circuit diagram relating to the corre- sponding assembly number. VU Meters PPM Meters 20 10 dB GRM 20 dB 10 7 5 3 2 1 0 1 2 3 + VU 100 80 40 60 20 % 20 0 dB GRM 20
7、dB 10 7 5 3 2 1 0 1 2 3 + VU 00 80 40 60 20 % 00 8080 40 60 20 % 20 0 dB GRM 20 dB 10 7 5 3 2 1 0 1 2 3 + VU 00 80 40 60 20 % 20 0 dB GRM 20 dB 10 7 5 3 2 1 0 1 2 3 + VU 00 80 40 60 20 % 20 10 dB GRM 20 dB 10 7 5 3 2 1 0 1 2 3 + VU 100 80 40 60 20 % 20 0 dB GRM 20 dB 10 7 5 3 2 1 0 1 2 3 + VU 00 80
8、40 60 20 % 00 20 10 dB GRM dB 12 + PPM 20 0 dB GRM 20 0 dB GRM 20 0 dB GRM 20 10 dB GRM 20 0 dB GRM 6 0 6 12 18 24 dB 12 + PPM 6 0 6 12 18 24 dB 12 + PPM 6 0 6 12 18 24 dB 12 + PPM 6 0 6 12 18 24 dB 12 + PPM 6 0 6 12 18 24 dB 12 + PPM 6 0 6 12 18 24 20 dB 10 7 5 3 2 1 0 1 2 3 + VU 100 80 40 60 20 %
9、100 8080 40 60 20 % 100 dB 12 + PPM 6 0 6 12 18 24 dB 12 + PPM 6 0 6 12 18 24 7 + 3 + 2 + 1 0 1 3 5 0 20 dB + 3 + 2 + 1 0 1 3 5 0 20 dB 1.913.102 * 1.913.104 1.913.106 * 1.913.108 1.913.322 * 1.913.324 1.913.101 * 1.913.103 1.913.105 * 1.913.107 1.913.321 * 1.913.323 * Versions without gain reductio
10、n meter (GRM) 1.913.606 * 1.913.605 *1.913.610 * 4040120 170 170 4040120 40 4040 190 190 1.913.101-.108/.321-.324/.605-.610 Date printed: 12.06.2002 10.27.1481 (0602) VU/PPM Meters 3 2 Functional Description PPM: The peak program meter is a quasi-peak value instrument with long decay time. When a si
11、gnal voltage corresponding to a level of 0 dB is applied for 10 ms, the resulting indication is 1 dB. Decay time (0 to 20 dB) is 1.7 s. VU Meter: The VU meter indicates signals according to the standard defined by ANSI 1954. When a signal with a duration of 300 ms is applied, the indication is 99% o
12、f the reference value. Rise and decay times on a VU meter are iden- tical. The factory-set lead is +6 dB. Gain Reduction Meter: When the limiter/compressor is switched on, the GRM indicates the magni- tude of the gain reduction. Small PPM: The assembly 1.913.610 contains an additional small PPM mete
13、r with 10 LEDs, normally used for AUX level indication. Bar/Dot Display Selection: On each of the PCBs, selection of bar or dot display mode is provided. All level meters are factory-set to bar display mode; dot display mode is un- usual and recommended only if extra-low current consumption is requi
14、red. PCB No. Bar Display Mode (Default Factory Setting) Dot Display Mode 1.913.293.00 (VU/PPM 30 LED w. GRM) insert: R3, R8, R10, R15 remove: R4, R9, R11, R14 insert: R4, R9, R11, R14 remove: R3, R8, R10, R15 1.913.294.00 (VU/PPM 30 LED) insert: R3, R8, R10 remove: R4, R9, R11 insert: R4, R9, R11 re
15、move: R3, R8, R10 1.913.291.00 (PPM 10 LED) insert jumper JS201 remove jumper JS201 3 Technical Specifications General: 0 dBu 0.775 Vrms Sensitivity for reference indication 1 dBu . +16 dBu Input impedance 10 k Supply 15 VDC +24 VDC Quiescent: 45 mA 35 mA Current consumption without GRM (p. ch., bar
16、 display mode) Full load: 80 mA 80 mA Quiescent: 55 mA 45 mA Current consumption with GRM (p. ch., bar display mode) Full load: 105 mA 105 mA VU Meter (1.913.293): Indication range 20 VU . +3 VU Accuracy (conditions: 10.+3 VU, 0.+50 C, 31.5 Hz.16 kHz) 1 segment Response time to 1 VU 207 ms 30 ms PPM
17、 (1.913.293): Indication range 30 dBu . +15 dBu Accuracy (conditions: 30.+15 VU, 0.+50 C, 31.5 Hz.16 kHz) 1 segment Dynamic behavior 0 dB, 10 ms burst Indication: 1 dB 0.5 dB Jumper normal 0 dB, 3 ms burst Indication: 4 dB 1 dB Jumper fast 0 dB, 100 s burst Indication: 1 dB Decay time: 0.20 dB 1.7 s
18、 0.3 s GRM (1.913.294): Input voltage range min. control: 0 V . +2 VDC max. control: 0 V . +11 VDC Dimensions: 1- and 2-channel units, dark front panel (w h d) 40 170 97 mm 2-channel units, bright front panel (w h d) 40 190 97 mm 4-channel units, dark front panel (w h d) 120 170 97 mm 1.913.101-.108
19、/.321-.324/.605-.610 4 VU/PPM Meters 10.27.1481 (0602) Date printed: 12.06.2002 4 VU/PPM Meter Block Diagram VU/PPM meter block diagram: VU/PPM/PPM FAST and LIN/LOG settings are established with jumpers J2 and J3, respectively. 5 Alignment Required Instruments: AC voltmeter, Ri 20 k DC voltmeter, Ri
20、 100 k AF generator, 31.5 Hz . 16 kHz, 0.16 dBu; attenuator with 10 dB incre- ments. DC/DC Converter Check: Connect DC voltmeter to TP5 (hot) and TP4 (ground). Feed generator out- put signal with line level (1.+16 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9); all green LEDs are on. DC volt
21、meter reading should be: 3.1 0.1 VDC (supply: +24 VDC), 4.1 0.1 VDC (supply: +30 VDC). Input Range: Feed generator output signal with line level (1 kHz, 1.+16 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9). Connect AC voltmeter to test points TP1 (hot) and TP4 (ground). Reading must be adjus
22、table with RA3 to 290 10 mVAC for the complete input level range. Line Level: Feed generator output signal with your line level (1 kHz, range: 1.+16 dBu) to the input (pins 5 and 7 of P1, or TP8 and TP9). Adjust RA3 until all green LEDs are on. The red LEDs must be dark. (TP3: 2.5 0.1 VDC). Rectifie