1、US Model Canadian Model Dolby and the double-D symbol are the trade marks of Dolby Laboratories Licensing Corporation. Noise reduction system manufactured under license from Dolby Laboratories Licensing Corporation. SPECIFICATIONS Recording system 4-track 2-channel stereo Fast-forward and rewind tim
2、e Approx. 100 sec. (with C-60 cassette) Bias frequency 105 kHz Signal-to-noise ratio (NAB, at peak level) OFF B-TYPE ON C-TYPE ON TYPE IV (Sony METALLIC) 56 dB 65 dB 71 dB TYPE III (Sony FeCr) 59 dB 66 dB 72 dB TYPE II (Sony UCX) 56 dB 63 dB 69 dB TYPE I (Sony BHF or HFX) 54 dB 61 dB 67 dB Total har
3、monic distortion 1 0% (with Sony METALLIC and FeCr cassettes) SAFETY-RELATED COMPONENT WARNING! COMPONENTS IDENTIFIED BY SHADING AND MARK ON THE SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR
4、 AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. AEP Model UK Model E Model Frequency response DOLBY NR OFF ?With TYPE IV cassette (Sony METALLIC) 20 18,000 Hz 30 - 16,000 Hz (3 dB), (DIN) 30 - 13,000 Hz (3 dB, 0 VU recording) ?With TYPE III cassette (Sony FeCr) 20 - 16,000 Hz 30 - 16,0
5、00 Hz (3 dB), (DIN) ?With TYPE II cassette (Sony UCX) 20 17,000 Hz 30 - 15,000 Hz (3 dB), (DIN) ?With TYPE I cassette (Sony BHF or HFX) 20 - 16,000 Hz Continued on page 2- ATTENTION AU COMPOSANT AYANT RAPPORT A LA SECURITE! LES COMPOSANTS IDENTIFIES PAR UNE TRAME ET U N E M A R Q U E SUR LES DIAGRAM
6、MES SCHE- MATIQUES, L E S V U E S ECLATEES E T L A LISTE D E S PIECES S0NT CRITIQUES POUR LA SECURITE DE FONCTIONNEMENT. NE REMPLACER CES COMPO- SANTS QUE PAR DES PIECES SONY DONT LES NU- MEROS SONT DONNES DANS CE MANUEL OU OANS LES SUPPLEMENTS PUBLIES PAR SONY. STEREO CASSETTE DECK S O N Y : MICROF
7、ILM RadioFans.CN 收音机爱 好者资料库 Wow and Flutter: 0.05% WRMS (NAB) 0.14% (DIN) Inputs: Microphone inputs (phone jacks) Sensitivity 0.25 mV (-70 dB) For a low-impedance microphone Line inputs (phono jacks) Sensitivity 77.5 mV (-20 dB) Input impedance 47 k ohms outputs: Line outputs (phono jacks) Output le
8、vel 0.44 V (-5 dB) at load impedance 47 k ohms Load impedance over 10 k ohms Headphone output Output level -28dB at a load impedance of 8 ohms General Power Requirements: AEP model: 220 V ac, 50/60 Hz (240 V ac adjustable by authorized Sony personnel) UK model: 240 V ac, 50 Hz (220 V ac adjustable b
9、y authorized Sony personnel) US, Canadian model: 120 V ac, 60 Hz E model: 110,120,220 or 240 V ac ad- justable, 50/60 Hz Power Consumption: 14 watts Dimensions: Approx. 430 x 105 x 275 mm (w/h/d) (17 x 4, x inches) including projecting parts and controls Weight: US, Canadian, AEP, UK model: Approx.
10、4.4 kg (9lbs 12oz) E model: Approx. 4.5 kg (9 Ibs 15oz) (OdB=0.775V 1 1 Tape Transport Mechanism Type 1 TCM-130VlO FEATURES Dolby NR C-type noise reduction system In addition to the conventional B-type Dolby NR system, this cassette deck employs the newly-developed C-type Dolby NR system which reduc
11、es tape noise twice as effectively as the B-type system. The C-type system also incorporates an anti-saturation network to improve the high-frequency dynamic range by 4 dB at 10 kHz. Full-logic “feather-touch” operation At the slightest touch, the “feather-touch” function buttons enable you to switc
12、h directly from one mode to another without going through the stop mode. Blank skip function Blank spaces of at least 10 seconds long can be skipped in the fast- forward mode so that only he recorded portions of the tape are played back. Music scan function The first 10 seconds or so of all the sele
13、ctions on a tape can be played back in sequence. Thus the particular selection can be located easily. Repeat play Playback of one side of the cassette can be repeated five times. At the end of the tape, the cassette deck will automatically go into he rewind mode, and playback will be repeated from t
14、he beginning of the tape. AMS (Automatic Music Sensor) The AMS locates the beginning of he selection being played, or the following selection, by searching either forward, or in reverse, for the blank space between selections, and then plays back the selec- tion automatically. Automatic tape select
15、system The tape type is automatically detected and the recorder is ad- justed to its optimum bias current for recording and the optimum equalization for both recording and playback by simply Inserting the cassette in the cassette holder. Auto play The auto play function makes automatic replay possib
16、le promp ly after the tape is rewound to the beginning. Remote control operation Using he optional RM-50, RM-51 or RM-80 remote control unit, various operations-recording, playback, AMS, record muting operation, etc.-can be remotely controlled. When the RM-65 syn- chro remote control unit is used to
17、 connect this cassette deck with a turntable equipped with a synchro remote control jack, the opera- tion of the cassette deck and the turntable will be synchronized. Timer-activated recording or playback A timer switch is provided to turn the deck on and off at times preset on an optional timer. Ra
18、dioFans.CN 收音机爱 好者资料库 0 POWER switch This turns the power on or off. The peak level meters illuminate when the unit is turned on. REC LEVEL (recording level) controls These controls adjust the recording level. The upper slide bar is for the left channel and the lower for the right channel. Tape COUN
19、TER and RESET button The tape counter provides a numerical reference point while record- ing which can be used to index a recorded cassette. To reset to zero. press the RESET button. TAPE SELECT switch and tape type indicators Generally set this switch to AUTO (n). The automatic tape select system w
20、ill then operate. When using a TYPE Ill (Fe-Cr) cassette or a TYPE IV (METAL) cassette which has no METAL tape detector slots, depress this switch to set it to the TYPE Ill (IV) position When Inserting a cassette, one of the tape type indicators will light up depending on the type of tape and the po
21、sition of the TAPE SELECT switch. L E V E L M E T E R S These meters show the peak input level of each channel during recording, and recorded levels in the playback mode. They follow the transient peaks of high-level inputs that are too brief to be followed by conventional VU meters so that he optim
22、um recording level can be accurately set. Function buttons It is possible to switch directly from one mode to another. The in- dicator lamps on the buttons light to show the operating mode (ex- cept the and ?buttons). (forward) button : Press this button to play the tape back. To record, press this
23、button while holding the button down. (rewind) button : Press this button to rewind the tape. This button is also used for “AMS” and “Auto play”. AMS button : Press this button and or button for AMS function. (fast-forward) button : Press this button to advance the tape rapidly. This button IS also
24、used for “AMS”. (stop) button : To stop the tape, press this button. The tape will stop automatically when it is completely wound in either direc- tion. ?(record) button : Press this button together with the) button to start recording. Also press this button before adjusting the recording level. (re