1、SERVICE MANUAL Sony Corporation Audio Group Published by Sony Engineering Corporation US Model Canadian Model AEP Model UK Model SUPER AUDIO CD PLAYER 9-879-006-02 2005E16-1 2005.05 Ver. 1.1 2005.05 SPECIFICATIONS SCD-CE595 General LaserSemiconductor laser (Super Audio CD: = 650 nm) (CD: = 780 nm) E
2、mission duration: continuous Power requirements US, Canadian: AEP, UK: When a Super Audio CD is played Playing frequency range2 Hz to 100 kHz Frequency response2 Hz to 40 kHz (3 dB) Dynamic range100 dB or more Total harmonic distortion rate 0 0035 % or less Wow and flutterValue of measurable limit (
3、0 001 % W PEAK) or less When a CD is played Frequency response2 Hz to 20 kHz Dynamic range96 dB or more Total harmonic distortion rate 0 0039 % or less Wow and flutterValue of measurable limit (0 001 % W PEAK) or less Output connector * Output only the audio signals of the CD Jack typeOutput level L
4、oad impedance ANALOG 5 1CH OUT Phono jacks 2 Vrms (at 50 kilohms) Over 10 kilohms DIGITAL (CD) OUT OPTICAL* Square optical output connector 18 dBm(Light emitting wave length: 660 nm) 1 230 V AC, 50/60 Hz 20 V AC, 60 Hz Power consumption15 W Dimensions (w/h/d)430 110 420 mm incl projecting parts Mass
5、 (approx )5 5 kg Supplied accessories Audio connecting cordRed and White 2 (1) Remote commanderRM-SX800 (1) BatteryR6 (size-AA) (2) Design and specifications are subject to change without notice Model Name Using Similar MechanismNEW CD Mechanism TypeCDM79C-DVBU51 Optical Pick-up NameDBU-3 RadioFans.
6、CN 收音机爱 好者资料库 2 SCD-CE595 Notes on chip component replacement Never reuse a disconnected chip component. Notice that the minus side of a tantalum capacitor may be damaged by heat. Flexible Circuit Board Repairing Keep the temperature of the soldering iron around 270 C during repairing. Do not touch
7、the soldering iron on the same conductor of the circuit board (within 3 times). Be careful not to apply force on the conductor when soldering or unsoldering. CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposu
8、re. This appliance is classified as a CLASS 1 LASER product This label is located on the rear exterior The laser diode in the optical pick-up block may suffer electrostatic break-down because of the potential difference generated by the charged electrostatic load, etc. on clothing and the human body
9、. During repair, pay attention to electrostatic break-down and also use the procedure in the printed matter which is included in the repair parts. The flexible board is easily damaged and should be handled with care. NOTES ON LASER DIODE EMISSION CHECK The laser beam on this model is concentrated so
10、 as to be focused on the disc reflective surface by the objective lens in the optical pick- up block. Therefore, when checking the laser diode emission, observe from more than 30 cm away from the objective lens. NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK OR BASE UNIT LASER DIODE AND FOCUS SEARCH OP
11、ERATION CHECK Carry out the “S curve check” in “CD section adjustment” and check that the S curve waveform is output three times. TABLE OF CONTENTS 1.SERVICING NOTES .3 2.GENERAL .4 3.TEST MODE.6 4.DIAGRAMS 4-1.Block Diagram .8 4-2.Printed Wiring Board RF Section .9 4-3.Schematic Diagram RF Section
12、. 10 4-4.Printed Wiring Board MAIN Section . 11 4-5.Schematic Diagram MAIN Section (1/4) . 12 4-6.Schematic Diagram MAIN Section (2/4) . 13 4-7.Schematic Diagram MAIN Section (3/4) . 14 4-8.Schematic Diagram MAIN Section (4/4) . 15 4-9.Printed Wiring Board DISPLAY Section . 16 4-10. Schematic Diagra
13、m DISPLAY Section . 17 4-11. Printed Wiring Board MD-94 Board Section . 18 4-12. Schematic Diagram MD-94 Board Section . 19 5.EXPLODED VIEWS 5-1.Main Section. 22 5-2.Front Panel Section . 23 5-3.Chassis Section. 24 5-4.CD Mechanism Section (1) (CDM79C-DVBU51) . 25 5-5.CD Mechanism Section (2) (CDM79
14、C-DVBU51) . 26 6.ELECTRICAL PARTS LIST .27 SAFETY-RELATED COMPONENT WARNING! COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITH MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS
15、MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY. ATTENTION AU COMPOSANT AYANT RAPPORT LA SCURIT! LES COMPOSANTS IDENTIFIS PAR UNE MARQUE 0 SUR LES DIAGRAMMES SCHMATIQUES ET LA LISTE DES PICES SONT CRITIQUES POUR LA SCURIT DE FONCTIONNEMENT. NE REMPLACER CES COM- POSANTS QUE PAR DES PICES SONY DONT LES NU
16、MROS SONT DONNS DANS CE MANUEL OU DANS LES SUPPLMENTS PUBLIS PAR SONY. RadioFans.CN 收音机爱 好者资料库 3 SCD-CE595 SECTION 1 SERVICING NOTES HOW TO OPEN THE DISC TRAY WHEN POWER SWITCH TURNS OFF Insert a tapering driver into the aperture of the unit bottom, and turn in the direction of arrow. Use a flat (-)
17、 head screwdriver to open the disc tray by manual operation. (Flat head screwdriver with nominal blade length of 3mm.) * To close the disc table, turn the driver in the reverse direction. tapering driver 1 2 Parts No. MODEL IDENTIFICATION Back Panel MODELPart No. US Model4-255-250-0 Canadian Model4-
18、255-250-1 AEP Model4-255-250-2 UK Model4-255-250-3 SAFETY CHECK-OUT After correcting the original service problem, perform the following safety check before releasing the set to the customer: Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for A
19、C leakage. Check leakage as described below. LEAKAGE TEST The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes.). Leakage current can be measured by any one of three
20、methods. 1.A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers instructions to use these instruments. 2.A battery-operated AC milliammeter. The Data Precision 245 digital multimeter is suitable for this job. 3.Measuring the voltage drop across a resistor by
21、means of a VOM or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so analog meters must have an accurate low-voltage scale. The Simpson 250 and Sanwa SH-63Trd are examples of a passive VOM that is suitable. Nearly all battery operated digital multimeters that have a 2 V AC range are
22、 suitable. (See Fig. A) Fig. A.Using an AC voltmeter to check AC leakage. 1.5 k0.15 F AC voltmeter (0.75 V) To Exposed Metal Parts on Set Earth Ground 4 SCD-CE595 SECTION 2 GENERAL This section is extracted from instruction manual. Front Panel A POWER switch (9) B DISC 1-5 buttons (9, 14) Press to s
23、elect the disc directly. C Remote sensor (6) D Display window (10) E H button (9, 13, 14) F X button (9) G x button (9, 15) H m/M buttons (13) I l AMS L dial (AMS: Automatic Music Sensor) (8, 9, 10, 12, 13, 14, 16, 17, 19) J EX-CHANGE button (12) Press to replace discs while playing a disc. K DISC S