《Pioneer-CDJ-1000-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-CDJ-1000-Service-Manual电路原理图.pdf(92页珍藏版)》请在收音机爱好者资料库上搜索。
1、ORDER NO. ? ? ? ? ? ? RRV2468 CDJ-1000 1. SAFETY INFORMATION.2 2. EXPLODED VIEWS AND PARTS LIST . 4 3. BLOCK DIAGRAM AND SCHEMATIC DIAGRAM 12 4. PCB CONNECTION DIAGRAM.38 5. PCB PARTS LIST.52 6. ADJUSTMENT.57 7. GENERAL INFORMATION.59 CONTENTS 7.1 DIAGNOSIS.59 7.1.1 SERVICE MODE . 59 7.1.2 ERROR DIS
2、PLAY.61 7.1.3 DISASSEMBLY . 62 7.1.4 PART REPLACEMENT METHOD OF JOG SECTION.66 7.1.5 ABOUT ELECTRIC DISCHARGE.69 7.1.6 SEQUENCE AFTER THE POWER ON . 70 7.2 PARTS . 71 7.2.1 IC.71 8. PANEL FACILITIES AND SPECIFICATIONS.87 THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). COMPACT DISC P
3、LAYER Remarks Type Model CDJ-1000 Power Requirement KUCOAC120V TLOAC110- 240V WYOAC220- 240V RadioFans.CN 收音机爱 好者资料库 CDJ-1000 2 1. SAFETY INFORMATION 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. ANY MEASUREMENTS NO
4、T WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A PO- TENTIAL SHOCK HAZARD AND MUST BE COR- RECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electrical and mechanical parts in the appli- ance have special safety related characteristics. These are often not ev
5、ident from visual inspection nor the protection afforded by them necessarily can be ob- tained by using replacement components rated for voltage, wattage , etc. Replacement parts which have these special safety characteristics are identified in this Service Manual. Electrical components having such
6、features are identified by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety characteristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may
7、create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER Service Manual. A subscription to, or ad- ditional copies of, PIONEER Service Manual may be obtained at
8、a nominal charge from PIONEER. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe, conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output termin
9、als, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA. (FOR USA MODEL ONLY) Also test with plug reversed (Using AC adapter plug as required) Devic
10、e under test Test all exposed metal surfaces Earth ground Leakage current tester Reading should not be above 0.5 mA AC Leakage Test REMARQUE (POUR MODLE CANADIEN SEULEMENT) Les symboles de fusible (fusible de type rapide) et/ou (fusible de type lent) sur CCI indiquent que les pices de remplacement d
11、oivent avoir la mme dsignation. NOTICE (FOR CANADIAN MODEL ONLY) Fuse symbols (fast operating fuse) and/or (slow operating fuse) on PCB indicate that replacement parts must be of identical designation. This service manual is intended for qualified service technicians; it is not meant for the casual
12、do-it-yourselfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the
13、 warranty. If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to th
14、e state of California to cause cancer, birth defects or other reproductive harm. Health , ) TRACK numbers beyond the current track lights. When the next track is 21 or beyond, lights. When Cue points or loops are stored, an underscore lights in the correspond- ing TRACK numbers. TRACK Number indicat
15、or Displays TRACK numbers. fi Auto Cue indicator (A. CUE) Lights when auto cue is on. fl REMAIN indicator Indicates that track remaining time is being displayed. Time display (min) (M) Time display (sec) (S) Frame display (F) One second is 75 frames. Playback Tempo display (TEMPO) Indicates the rate
16、 of change in the playback tempo. Tempo Adjustment Range indicator (6, 10, 16, 24) Indicates the variable range of the Tempo Control knob selected with the TEMPO Control Range button. Reverse indicator (REV) Indicates that the DIRECTION FWD/REV switch is set to reverse (REV position). MEMORY LOOP in