《Pioneer-CDJ-1000-Mk3-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Pioneer-CDJ-1000-Mk3-Service-Manual电路原理图.pdf(116页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ORDER NO. CDJ-1000MK3 RRV3353 COMPACT DISC PLAYER CDJ-1000MK3 THIS MANUAL IS APPLICABLE TO THE FOLLOWING MODEL(S) AND TYPE(S). ModelTypePower RequirementRemarks CDJ-1000MK3KUCXJAC 120V CDJ-1000MK3WYXJ5AC 220-240V CDJ-1000MK3TLFXJAC 110-240V For details, refer to Important Check Points for good serv
2、icing. RadioFans.CN 收音机爱 好者资料库 CDJ-1000MK3 2 1234 1234 C D F A B E SAFETY INFORMATION 1. SAFETY PRECAUTIONS The following check should be performed for the continued protection of the customer and service technician. LEAKAGE CURRENT CHECK Measure leakage current to a known earth ground (water pipe,
3、conduit, etc.) by connecting a leakage current tester such as Simpson Model 229-2 or equivalent between the earth ground and all exposed metal parts of the appliance (input/output terminals, screwheads, metal overlays, control shaft, etc.). Plug the AC line cord of the appliance directly into a 120V
4、 AC 60 Hz outlet and turn the AC power switch on. Any current measured must not exceed 0.5 mA. ANY MEASUREMENTS NOT WITHIN THE LIMITS OUTLINED ABOVE ARE INDICATIVE OF A POTENTIAL SHOCK HAZARD AND MUST BE CORRECTED BEFORE RETURNING THE APPLIANCE TO THE CUSTOMER. 2. PRODUCT SAFETY NOTICE Many electric
5、al and mechanical parts in the appliance have special safety related characteristics. These are often not evident from visual inspection nor the protection afforded by them necessarily can be obtained by using replacement components rated for voltage, wattage, etc. Replacement parts which have these
6、 special safety characteristics are identified in this Service Manual. Electrical components having such features are identified by marking with a on the schematics and on the parts list in this Service Manual. The use of a substitute replacement component which does not have the same safety charact
7、eristics as the PIONEER recommended replacement one, shown in the parts list in this Service Manual, may create shock, fire, or other hazards. Product Safety is continuously under review and new instructions are issued from time to time. For the latest information, always consult the current PIONEER
8、 Service Manual. A subscription to, or additional copies of, PIONEER Service Manual may be obtained at a nominal charge from PIONEER. Leakage current tester Reading should not be above 0.5 mA Device under test Test all exposed metal surfaces Also test with plug reversed (Using AC adapter plug as req
9、uired) Earth ground AC Leakage Test (FOR USA MODEL ONLY) WARNING This product contains lead in solder and certain electrical parts contain chemicals which are known to the state of California to cause cancer, birth defects or other reproductive harm. Health it is not meant for the casual do-it- your
10、selfer. Qualified technicians have the necessary test equipment and tools, and have been trained to properly and safely repair complex products such as those covered by this manual. Improperly performed repairs can adversely affect the safety and reliability of the product and may void the warranty.
11、 If you are not qualified to perform the repair of this product properly and safely, you should not risk trying to do so and refer the repair to a qualified service technician. RadioFans.CN 收音机爱 好者资料库 CDJ-1000MK3 3 5678 56 7 8 C D F A B E WARNING ! THE AEL (ACCESSIBLE EMISSION LEVEL) OF THE LASER PO
12、WER OUTPUT IS LESS THAN CLASS 1 BUT THE LASER COMPONENT IS CAPABLE OF EMITTING RADIATION EXCEEDING THE LIMIT FOR CLASS 1. A SPECIALLY INSTRUCTED PERSON SHOULD DO SERVICING OPERATION OF THE APPARATUS. LASER DIODE CHARACTERISTICS MAXIMUM OUTPUT POWER : 5 mW WAVELENGTH : 780 785 nm IMPORTANT THIS PIONE
13、ER APPARATUS CONTAINS LASER OF CLASS 1. SERVICING OPERATION OF THE APPARATUS SHOULD BE DONE BY A SPECIALLY INSTRUCTED PERSON. Additional Laser Caution 1. Laser Interlock Mechanism The position of the switch (S2401) for detecting loading completion is detected by the system microprocessor, and the de
14、sign prevents laser diode oscillation when the switch is not in LPS1 terminal side (when the mechanism is not clamped and LPS1 signal is high level.) Thus, the interlock will no longer function if the switch is deliberately set to LPS1 terminal side. ( if LPS1 signal is low level ). In the test mode
15、 the interlock mechanism will not function. Laser diode oscillation will continue, if pin 5 of AN22022A (IC601) on the MAIN Assy is connected to GND, or else the terminals of Q603 are shorted to each other (fault condition). 2. When the cover is opened, close viewing of the objective lens with the n