Philips-MZ-1200-Service-Manual电路原理图.pdf
《Philips-MZ-1200-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-MZ-1200-Service-Manual电路原理图.pdf(62页珍藏版)》请在收音机爱好者资料库上搜索。
1、GBCLASS 1LASER PRODUCTCOMPACTDIGITAL AUDIOService ManualServiceServiceServiceMZ-1000/22 fr Reparaturen sind Original-Ersatzteile zu verwenden.ILe norme di sicurezza esigono che lapparecchio venga rimessonelle condizioni originali e che siano utilizzati i pezzi di ricambioidentici a quelli specificat
2、i.“After servicing and before returning set to customer perform aleakage current measurement test from all exposed metal parts toearth ground to assure no shock hazard exist. The leakage currentmust not exceed 0.5mA.“CLASS 1LASER PRODUCT3122 110 03420GB Warning !Invisible laser radiation when open.A
3、void direct exposure to beam.S Varning !Osynlig laserstrlning nr apparaten r ppnad och sprrenr urkopplad. Betrakta ej strlen.SF Varoitus !Avatussa laitteessa ja suojalukituksen ohitettaessa olet alttiinankymttmlle laseristeilylle. l katso steeseen!DK Advarse !Usynlig laserstrling ved bning nr sikker
4、hedsafbrydere erude af funktion. Undg udsaettelse for strling.1-6DISMANTLING INSTRUCTIONS (CENTRE UNIT)Dismantling of the Cladding1) Remove 8 Plug Rubbers (pos 123, 124, 125) from bothside of the Centre Unit (for MZ-1100 only) with a flat headscrew driver (see Figure 1).Figure 1Dismantling of the Co
5、ver Orn Rear and Cladding Internal1) Remove 5 screws D and 2 screws E (see Figure 5) toloosen the Cover Orn Rear (pos 119).2) Remove 4 screws F (see Figure 6) to loosen the CladdingInternal Left (pos 117) and Cladding Internal Right (pos118).2-1 2-1Dismantling of the Control BoardDISMANTLING INSTRUC
6、TIONS (CENTRE UNIT)Dismantling of the Front Cover Assembly1) Remove 2 screws B (see Figure 3 and Figure 6) anduncatch C1 (see Figure 3) with a small size screw driver bygivivg a push in the direction as shown in Figure 4 toseparate the Front Cover Assembly from the Centre Unit(see Service Position A
7、 for Centre Unit).1) Remove 7 screws G (see Figure 7) to loosen the ControlBoard (pos 1003-A).2) Remove 2 screws H (see Figure 7) to loosen the IR EyeBoard (pos 1003-B).Figure 2Figure 3 Figure 4Figure 5Figure 6Figure 72) Remove 8 screws A (see Figure 2) from both side of theCentre Unit to loosen the
8、 Cladding (pos 120).2-2 2-21) Remove 4 screws J (see Figure 8) from both side of thePower Box to loosen the Cabinet Top Power Box (pos229) and Cabinet Bottom Power Box (pos 230).Service position AService position CService position BDISMANTLING INSTRUCTIONS (CENTRE UNIT) DISMANTLING INSTRUCTIONS (POW
9、ER BOX)Dismantling of the Power Box CabinetFigure 8Figure 9Figure 102) Uncatch C2 (see Figure 9) to separate the Cabinet FrontPower Box (pos 227) and Cabinet Rear Power Box (pos228) from the chassis.3) Remove 8 screws K (see Figure 10) to loosen theChassis Top of the Power Box (see Service position
10、A forPower Box).2-3 2-3Service position AService position CRepair Hints1) Remove 3 screws L (see Figure 11 and Figure 12) toloosen the Amplifier Board (pos 1102).2) Remove 2 screws M (see Figure 12) to loosen theInterconnect Board (pos 1103).Service position BDISMANTLING INSTRUCTIONS (POWER BOX)Dism
11、antling of the Amplifier Board and Supply Board and Interconnect Board3) Remove 3 screws N (see Figure 11 and Figure 12) toloosen the Supply Board (pos 1101).DISMANTLING INSTRUCTIONS (POWER BOX)Figure 11Figure 121) WARNINGSwitching Mode Power Supply (SMPS) Board consists of high voltage filter capac
12、itors (2203 or 2210).Safety measures must be taken by the repair technician during servicing:- When the supply is on, avoid touching the SMPS Board and the high voltage filter capacitors (2203 or 2210).- When the supply is off, make sure to discharge the high voltage filter capacitors (2203 or 2210)