Philips-HTS-3181-X-Service-Manual电路原理图.pdf
《Philips-HTS-3181-X-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-HTS-3181-X-Service-Manual电路原理图.pdf(52页珍藏版)》请在收音机爱好者资料库上搜索。
1、 1 1 Copyright 2009 Philips Consumer Electronics B.V. Eindhoven, The NetherlandsAll rights reserved. No part of this publication may be reproduced, stored in a retrieval system ortransmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwisewithout the prior permission
2、of Philips.Published by RY0929 Service Audio Printed in The Netherlands Subject to modificationDVD Home Theater SystemVersion 1.0TABLE OF CONTENTSService ManualService3139 785 35050 GBChapter LASER BEAM SAFETY PRECAUTIONS.1-2 STANDARD NOTES FOR SERVICING. .1-3 SAFETY AND IMPORTANT NOTICE.1-7 LOCATIO
3、N OF PCB BOARDSVERSION VARIATION .2-1 OPERATING CONTROLS AND FUNCTIONS .2-2SPECIFICATIONS .3-1 MEASUREMENT SETUP.3-2 .SYSTEM,REGION CODE,ETC.SETTING PRODURE.3-3 RETURN UNIT TEST FLOW.3-4 MAIN UNIT REPAIR CHART.3-5 DISASSEMBLY INSTRUCTIONS .4 BLOCK WIRING DIAGRAM.5 AMPLIFIER BOARDLED + KEY BOARDDECOD
4、E BOARDPOWER BOARD.9 MECHANICAL EXPLODE VIEW PART LIST.10 REVISION LIST.11 .HTS3181/55 HTS3181X/78.6 .7 .8 LASER BEAM SAFETY PRECAUTIONS This DVD player uses a pickup that emits a laser beam. Do not look directly at the laser beam coming from the pickup or allow it to strike against your skin. The l
5、aser beam is emitted from the location shown in the figure. When checking the laser diode, be sure to keep your eyes at least 30 cm away from the pickup lens when the diode is turned on. Do not look directly at the laser beam. CAUTION: Use of controls and adjustments, or doing procedures other than
6、those specified herein, may result in hazardous radiation exposure. CAUTION LASER RADIATION WHEN OPEN. DO NOT STARE INTO BEAM. Location: Top of DVD mechanism. 1 - 2STANDARD NOTES FOR SERVICING Instructions for Connectors 1. When you connect or disconnect the FFC (Flexible Foil Connector) cable, be s
7、ure to first disconnect the AC cord. 2. FFC (Flexible Foil Connector) cable should be inserted parallel into the connector, not at an angle. Pb (Lead) Free Solder When soldering, be sure to use the Pb free solder. IDENTIFICATION: Regardless of special logo (not always indicated) One must treat all s
8、ets from 1.1.2005 onwards, a ccording next rules. Important note: In fact also products a little older can also be treated in this way as long as you avoid mixing solder-alloys (leaded/ lead-free). So best to always use SAC305 and the higher temperatures belong to this. Due to lead-free technology s
9、ome rules have to be respected by the workshop during a repair: Use only lead-free solder alloy Philips SAC305 with order code 0622 149 00106. If lead-free solder paste is required, please contact the manufacturer of your solder-equipment. In general use of solder paste within workshops should be av
10、oided because paste is not easy to store and to handle. Use only adequate solder tools applicable for leadfree solder alloy. The solder tool must be able To reach at least a solder-temperature of 400C, To stabilize the adjusted temperature at the solder-tip To exchange solder-tips for different appl
11、ications. Adjust your solder tool so that a temperature around 360C - 380C is reached and stabilized at the solder joint. Heating-time of the solder-joint should not exceed 4 sec. Avoid temperatures above 400C otherwise wear-out of tips will rise drastically and flux-fluid will be destroyed. To avoi
12、d wear-out of tips switch off un-used equipment, or reduce heat. Mix of lead-free solder alloy / parts with leaded solder alloy / parts is possible but PHILIPS recommends strongly to avoid mixed solder alloy types (leaded and lead-free). If one cannot avoid, clean carefully the solder-joint from old
13、 solder alloy and re-solder with new solder alloy (SAC305). Use only original spare-parts listed in the Service-Manuals. Not listed standard-material (commodities) has to be purchased at external companies. Special information for BGA-ICs:- always use the 12nc-recognizable soldering temperature prof
14、ile of the specific BGA (for desoldering always use highest lead-free 1 - 3temperature profile, in case of doubt) - lead free BGA-ICs will be delivered in so-called dry-packaging (sealed pack including a silica gel pack) to protect the IC against moisture. After opening, dependent of MSL-level seen
15、on indicatorlabel in the bag, the BGA-IC possibly still has to be baked dry. This will be communicated via AYS-website. Do not re-use BGAs at all. For sets produced before 1.1.2005, containing leaded soldering-tin and components, all needed spare-parts will be available till the end of the service-p
16、eriod. For repair of such sets nothing changes. On our website www.atyourservice.ce.P you find more information to: BGA-de-/soldering (+ baking instructions) Heating-profiles of BGAs and other ICs used in Philips-sets. You will find this and more technical information within the “magazine”, chapter
17、“workshop news”. For additional questions please contact your local repair-helpdesk. How to Remove / Install Flat Pack-IC 1. Removal With Hot-Air Flat Pack-IC Desoldering Machine: 1. Prepare the hot-air flat pack-IC desoldering machine, then apply hot air to the Flat Pack-IC (about 5 to 6 seconds).
18、(Fig. S-1-1) 2. Remove the flat pack-IC with tweezers while applying the hot air. 3. Bottom of the flat pack-IC is fixed with glue to the CBA; when removing entire flat pack-IC, first apply soldering iron to center of the flat pack-IC and heat up. Then remove (glue will be melted). (Fig. S-1-6) 4. R
19、elease the flat pack-IC from the CBA using tweezers. (Fig. S-1-6) CAUTION: 1. The Flat Pack-IC shape may differ by models. Use an appropriate hot-air flat pack-IC desoldering machine, whose shape matches that of the Flat Pack-IC. 2. Do not supply hot air to the chip parts around the flat pack-IC for
20、 over 6 seconds because damage to the chip parts may occur. Put masking tape around the flat pack-IC to protect other parts from damage. (Fig. S-1-2) 3. The flat pack-IC on the CBA is affixed with glue, so be careful not to break or damage the foil of each pin or the solder lands under the IC when r
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PhilipsHTS3181XServiceManual 电路 原理图