Philips-MCI-8080-Service-Manual电路原理图.pdf
《Philips-MCI-8080-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-MCI-8080-Service-Manual电路原理图.pdf(55页珍藏版)》请在收音机爱好者资料库上搜索。
1、Published by LM 1052 V PTY, PS, Text including RDS clock settingHDMI Audio supportYesEnglish1-2-CDisplay/ClockResolutionDotmatrix, 320 x 240 dots (QVGA), Color TFTSize3.5 inchesBacklightCan be turned on/ off and can be dimmedClock/ Date displayYesWallpaper/ ScreensaverYesAutomatic time setting via I
2、nternet (NTP)Yes, enabledSleep timerYesInternal (key) clickerYesOthersUPnPDMP (Local Renderer, Local Controlpoint)/ DMSNote Requires User-registration Rhapsody. Capable to connect to - Windows Media Player 11/12, Winamp, TwonkyMedia;- Philips Music Center WAC3500 / WAC7500 / MCi500H;- Philips NAS SP
3、D8020CC;- Mobile phone Nokia N85, N95,N900.Specifications and external appearance are subject to changes without notice. 1-2-D2. Safety Instructions, Warnings, Notes, and Abbreviation ListIndex of this chapter:2.1 Safety Instructions2.2 Warnings2.3 Notes2.4 Abbreviation List2.1 Safety InstructionsSa
4、fety regulations require the following during a repair:Connect the set to the Mains/AC Power via an isolation transformer ( 800 VA).Replace safety components, indicated by the symbol ,only by components identical to the original ones. Any other component substitution (other than original type) may i
5、ncrease risk of fire or electrical shock hazard.Safety regulations require that after a repair, the set must be returned in its original condition. Pay in particular attention to the following points: Route the wire trees correctly and fix them with the mounted cable clamps.Check the insulation of t
6、he Mains/AC Power lead for external damage. Check the strain relief of the Mains/AC Power cord for proper function.Check the electrical DC resistance between the Mains/AC Power plug and the secondary side (only for sets that have a Mains/AC Power isolated power supply): 1. Unplug the Mains/AC Power
7、cord and connect a wire between the two pins of the Mains/AC Power plug. 2. Set the Mains/AC Power switch to the “on” position (keep the Mains/AC Power cord unplugged!). 3. Measure the resistance value between the pins of the Mains/AC Power plug and the metal shielding of the tuner or the aerial con
8、nection on the set. The reading should be between 4.5 M: and 12 M:.4. Switch “off” the set, and remove the wire between the two pins of the Mains/AC Power plug. Check the cabinet for defects, to prevent touching of any inner parts by the customer. 2.2 WarningsAll ICs and many other semiconductors ar
9、e susceptible to electrostatic discharges (ESD ). Careless handling during repair can reduce life drastically. Make sure that, during repair, you are connected with the same potential as the mass of the set by a wristband with resistance. Keep components and tools also at this same potential.Be care
10、ful during measurements in the high voltage section.Never replace modules or other components while the unit is switched “on”. When you align the set, use plastic rather than metal tools. This will prevent any short circuits and the danger of a circuit becoming unstable. 2.3 Notes2.3.1 GeneralMeasur
11、e the voltages and waveforms with regard to the chassis (= tuner) ground ( ), or hot ground ( ), depending on the tested area of circuitry. The voltages and waveforms shown in the diagrams are indicative. Measure them in the Service Default Mode (see chapter 5) with a colour bar signal and stereo so
12、und (L: 3 kHz, R: 1 kHz unless stated otherwise) and picture carrier at 475.25 MHz for PAL, or 61.25 MHz for NTSC (channel 3).Where necessary, measure the waveforms and voltages with ( ) and without ( ) aerial signal. Measure the voltages in the power supply section both in normal operation ( ) and
13、in stand-by ( ). These values are indicated by means of the appropriate symbols.2.3.2 Schematic NotesAll resistor values are in ohms, and the value multiplier is often used to indicate the decimal point location (e.g. 2K2 indicates 2.2 k:).Resistor values with no multiplier may be indicated with eit
14、her an “E” or an “R” (e.g. 220E or 220R indicates 220 :).All capacitor values are given in micro-farads (P u10-6),nano-farads (n u10-9), or pico-farads (p u10-12).Capacitor values may also use the value multiplier as the decimal point indication (e.g. 2p2 indicates 2.2 pF).An “asterisk” (*) indicate
15、s component usage varies. Refer to the diversity tables for the correct values.The correct component values are listed in the Spare Parts List. Therefore, always check this list when there is any doubt.2.3.3 BGA (Ball Grid Array) ICsIntroductionFor more information on how to handle BGA devices, visi
16、t this URL: (needs subscription, not available for all regions). After login, select “Magazine”, then go to “Repair downloads”. Here you will find Information on how to deal with BGA-ICs.BGA Temperature ProfilesFor BGA-ICs, you must use the correct temperature-profile, which is coupled to the 12NC.
17、 For an overview of these profiles, visit the website (needs subscription, but is not available for all regions)You will find this and more technical information within the “Magazine”, chapter “Repair downloads”.For additional questions please contact your local repair help desk.2.3.4 Lead-free Sol
18、deringDue to lead-free technology some rules have to be respected by the workshop during a repair:Use only lead-free soldering tin Philips SAC305 with order code 0622 149 00106. If lead-free solder paste is required, please contact the manufacturer of your soldering equipment. In general, use of sol
19、der paste within workshops should be avoided because paste is not easy to store and to handle.Use only adequate solder tools applicable for lead-free soldering tin. The solder tool must be able: To reach a solder-tip temperature of at least 400C. To stabilize the adjusted temperature at the solder-t
20、ip. To exchange solder-tips for different applications.Adjust your solder tool so that a temperature of around 360C - 380C is reached and stabilized at the solder joint. Heating time of the solder-joint should not exceed 4 sec. Avoid temperatures above 400C, otherwise wear-out of tips will increase
21、drastically and flux-fluid will be destroyed. To avoid wear-out of tips, switch “off” unused equipment or reduce heat.Mix of lead-free soldering tin/parts with leaded soldering tin/parts is possible but PHILIPS recommends strongly to avoid mixed regimes. If this cannot be avoided, carefully clear th
22、e solder-joint from old tin and re-solder with new tin.1 - 3Safety Instructions, Warnings, Notes, and Abbreviation List2.3.5 Alternative BOM identificationIt should be noted that on the European Service website, “Alternative BOM” is referred to as “Design variant”.The third digit in the serial numbe
23、r (example: KX2B0835000001) indicates the number of the alternative B.O.M. (Bill Of Materials) that has been used for producing the specific AV set. In general, it is possible that the same AV model on the market is produced with e.g. two different types of display, coming from two different supplie
24、rs. This will then result in sets which have the same CTN (Commercial Type Number; e.g. MCM394/12) but which have a different B.O.M. number.Also, it is possible that same model on the market is producedwith two production centers, however their partslist is the same.In such case, no alternative B.O.
- 配套讲稿: