Philips-MCP-9360-I-Service-Manual电路原理图.pdf
《Philips-MCP-9360-I-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-MCP-9360-I-Service-Manual电路原理图.pdf(68页珍藏版)》请在收音机爱好者资料库上搜索。
1、MediaCenter PC ModelMCP9360iService ManualContents Pag e1. About this Manual 2 Contents Page2. Safety Instructions, Warnings and Notes 3 3. System Overview 5 4. Technical Reference 6 5. Required Equipment List 11 6. Diagnosis and Repair Flowchart 12 7. Installation and Initial Checks 13 8. Troublesh
2、ooting - Start-up Failure 16 9. Software Update and Repair 17 10. PC Doctor Diagnostic Tool 21 11. Hardware Tests 23 12. Hardware Repair 39 13. Software Re-installation 62 14. End Test 63 15. Parts Information 64 Copyright 2006 Philips Consumer Electronics B.V. Eindhoven, The Netherlands. All rights
3、 reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without prior permission of Philips. Published by Consumer Electronics Printed in the Netherlands Subject to modifica
4、tion EN 0000 000 00000 EN 2 1. MCP9360i About this Manual 1. About this Manual 1.1. Content of this Manual Note: The MCP9360i will be serviced on a modular level only. Faulty modules will be identified and replaced. Detailed circuit diagrams and technical information on a component level are therefo
5、re not provided in this document. 1.1.1. What is included in this Manual Safety Information System Overview Basic System Block Diagrams Parts / Module Identification Module Functional Descriptions Basic Module Technical Descriptions Basic Measuring Point Information Basic Fault Finding Strategy Modu
6、le Removal & Replacement Procedures Functionality Testing Procedures End Test Sequence / Checklist Parts List / 12NC Numbers 1.2. Additional Documentation The following documentation is supplied by Philips and must be kept with this Service Manual. MCP9360i Quick Install Guide MCP9360i Use Cases RC4
7、370 Remote Control User Manual Safety Instructions, Warnings and Notes MCP9360i 2. EN 3 2. Safety Instructions, Warnings and Notes 2.1. Safety Instructions 2.1.1. Safety components Replace safety components, indicated by the symbol , only by components identical to the original ones. Any other compo
8、nent substitution (other than original type) may increase risk of fire or electrical shock hazard. 2.1.2. After repair Safety regulations require that after a repair, the set must be returned in its original condition. Before returning the MCP9360i to the customer always do a safety check. Pay atten
9、tion to the built-in protective devices, leakage current and insulation resistance. 2.2. Warnings 2.2.1. General Never replace modules or other components while the unit is switched “on”. 2.2.2. ESD Protection All ICs and many other semi-conductors are susceptible to electrostatic discharges (ESD).
10、Careless handling during repair can reduce life drastically. When repairing, make sure that you are connected with the same potential as the mass of the set via a wrist wrap with resistance. Keep components and tools also at this potential. 2.3. Notes 2.3.1. Schematic notes All resistor values are i
11、n ohms, and the value multiplier is often used to indicate the decimal point location (e.g. 2K2 indicates 2.2 kohm). Resistor values with no multiplier may be indicated with either an “E“ or an “R“ (e.g. 220E or 220R indicates 220 ohm). All capacitor values are given in micro-farads ( = x10-6), nano
12、-farads (n = x10-9), or pico-farads (p = x10-12). Capacitor values may also use the value multiplier as the decimal point indication (e.g. 2p2 indicates 2.2 pF). An “asterisk“ (*) indicates component usage varies. Refer to the diversity tables for the correct values. The correct component values are
13、 listed in the Spare Parts List. Therefore, always check this list when there is any doubt. EN 4 2. MCP9360i Safety Instructions, Warnings and Notes 2.3.2. Led-free solder Philips CE is producing lead-free sets (PBF) from 1.1.2005 onwards. Identification: The bottom line of a type plate gives a 14-d
14、igit serial number. Digits 5 and 6 refer to the production year, digits 7 and 8 refer to production week (in example below it is 1991 week 18). Figure 2.1-1 Regardless of the special lead-free logo (which is not always indicated), one must treat all sets from this date onwards according to the rules
15、 as described below. Figure 2.1-2 Due to lead-free technology some rules have to be respected by the workshop during a repair: Use only lead-free soldering tin Philips SAC305 with order code 0622 149 00106. If lead-free solder paste is required, please contact the manufacturer of your soldering equi
16、pment. In general, use of solder paste within workshops should be avoided because paste is not easy to store and to handle. Use only adequate solder tools applicable for lead-free soldering tin. The solder tool must be able: - To reach a solder-tip temperature of at least 400 C. - To stabilize the a
17、djusted temperature at the solder-tip. - To exchange solder-tips for different applications. Adjust your solder tool so that a temperature of around 360 C 380 C is reached and stabilized at the solder joint. Heating time of the solder-joint should not exceed 4 sec. Avoid temperatures above 400 C, ot