Philips-MCD-288-Service-Manual电路原理图.pdf
《Philips-MCD-288-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-MCD-288-Service-Manual电路原理图.pdf(39页珍藏版)》请在收音机爱好者资料库上搜索。
1、GBCLASS 1LASER PRODUCTMCD288/All VersionsTABLE OF CONTENTSegaPTechnical Specifi cations .1-2Measurement setup .1-3Service Aids, Safety Instruction, etc. .1-4 to 1-5Lead-free Information & Service Instruction .1-6 to 1-7Installation & Preparations & Controls .1-8 to 1-15Troubleshooting .1-15 to 1-16D
2、isassembly Instructions & Service positions . 2Service Test Programs . 3Set Block diagram . 4Set Wiring diagram . 5Display Board & AMP Key Board . 6Tuner Board . 7Power Board . 8Woofer Output Board . 9Scart Board. 10Set Mechanical Exploded View & Parts List . 11Electrical Parts List . 12Revision Lis
3、t . 13Copyright 2009 Philips Consumer Electronics B.V. Eindhoven, The NetherlandsAll rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, or otherwise without the prior permissi
4、on of Philips.Published by SL 0910 Service Audio Printed in The Netherlands Subject to modifi cationDVD Micro Theatre3141 785 30806Version 1.6VIDEO CD1-2/37 /55 /93Aux in / CDR in x x x xLine OutVideo OutSurround OutSubwoofer OutPower Booster OutS-Video OutScart OutMatrix SurroundRDS xNews xDolby Pr
5、o Logic (DPL)Incredible SurroundKaraoke FeaturesVoltage Selector xECO Power Standby (VFD Display Off) x xECO6 Tuner Board - Systems Non-CenelecECO6 Tuner Board - Systems CenelecUSB DirectVERSION VARIATIONS:Type /Versions: MCD288 Features &Board in used:x/12 /98x x x xxxxxx xxLOCATION OF PCBSSPECIFIC
6、ATIONGENERAL:Mains voltage : 230V 10% /12 , 220V 10% /93120V 10% / 230V 10% /55/96/98Mains frequency : 50/60Hz /55/96/98Power consumption : 33dBIF rejection : 60dBImage rejection : 25dBDistortion at RF=1mV, dev. 75kHz : 33dBAMPLIFIER:Frequency response within 3dB : 100Hz-15kHzS-Bass & Loudness : ON/
7、OFFDigital Sound Control : Classic, Jazz, Rock, Pop or FlatHeadphone output at 32K : 700mV 2dBInput sensitivityDVD : -6dB track (Audio Disc1,Trk35)COMPACT DISC:Measurement done at output conn. of the DVD module.Frequency response within 1.0dB: 20Hz - 20kHzSignal/Noise ratio (A-weighted) : 70dBAChann
8、el Unbalance : 60dBAChannel crosstalk at 1kHz : 35dBChannel unbalance at 1kHz : 3dBOutput power :2 x 20W :2 x 50WPigtail Antenna Wire: 50Hz /12/93: 60Hz /37120V 10% /37Subwoofer Out (8, 10% THD)Mains Operation (Nominal, 6, 10% THD)Woofer within 6dB : 50Hz-180HzNormal, Concert, Drama, Action or SCI-F
9、IFor DVD:Channel Separation -400/1K/5K : 20/26/18dBS/N Ratio stereo input 80dB : 55dB(16K) : 35dB(20K) : 30dBS/N Luminance : 48dBVideo Bandwidth : 6MhzChroma/Luminance Delay : 80nsBurst/Chroma Ratio : 1.0Vpp(+10/-10%)Amplitude Output : 80ns1-31-7INFORMATION ABOUT LEAD-FREE SOLDERING Philips CE is pr
10、oducing lead-free sets from 1.1.2005 onwards. IDENTIFICATION: Regardless of special logo (not always indicated) one must treat all sets from 1 Jan 2005 onwards, according next rules: Example S/N: Bottom line of typeplate gives a 14-digit S/N. Digit 5&6 is the year, digit 7&8 is the week number, so i
11、n this case 2005 wk12 So from 0501 onwards = from 1 Jan 2005 onwards Important note: In fact also products of year 2004 must be treated in this way as long as you avoid mixing solder-alloys (leaded/ lead-free). So best to always use SAC305 and the higher temperatures belong to this. Due to lead-free
12、 technology some rules have to be respected by the workshop during a repair: Use only lead-free solder alloy Philips SAC305 with order code 0622 149 00106. If lead-free solder-paste is required, please contact the manufacturer of your solder-equipment. In general use of solder-paste within workshops
13、 should be avoided because paste is not easy to store and to handle. Use only adequate solder tools applicable for lead-free solder alloy. The solder tool must be able o To reach at least a solder-temperature of 40 o To stabilize the adjusted temperature at the solder-tip o To exchange solder-tips f
14、or different applications. Adjust your solder tool so that a temperature around is reached and stabilized at the solder joint. Heating-time of the solder-joint should not exceed 4 sec. Avoid temperatures above 400 otherwise wear-out of tips will rise drastically and flux-fluid will be destroyed. To
15、avoid wear-out of tips switch off un-used equipment, or reduce heat. Mix of lead-free solder alloy / parts with leaded solder alloy / parts is possible but PHILIPS recommends strongly to avoid mixed solder alloy types (leaded and lead-free). If one cannot avoid or does not know whether product is le
16、ad-free, clean carefully the solder-joint from old solder alloy and re-solder with new solder alloy (SAC305). Use only original spare-parts listed in the Service-Manuals. Not listed standard-material (commodities) has to be purchased at external companies. Special information for BGA-ICs: - always u
17、se the 12nc-recognizable soldering temperature profile of the specific BGA (for de-soldering always use the lead-free temperature profile, in case of doubt) - lead free BGA-ICs will be delivered in so-called dry-packaging (sealed pack including a silica gel pack) to protect the IC against moisture.
18、After opening, dependent of MSL-level seen on indicator-label in the bag, the BGA-IC possibly still has to be baked dry. (MSL=Moisture Sensitivity Level). This will be communicated via AYS-website. Do not re-use BGAs at all. For sets produced before 1.1.2005 (except products of 2004), containing lea
19、ded solder-alloy and components, all needed spare-parts will be available till the end of the service-period. For repair of such sets nothing changes. On our website www.atyourservice.ce.P you find more information to: BGA-de-/soldering (+ baking instructions) Heating-profiles of BGAs and other ICs
20、used in Philips-sets You will find this and more technical information within the “magazine“, chapter “workshop news“. For additional questions please contact your local repair-helpdesk. SERVICE INSTRUCTION 1. Unplug the AC Power cord and connect a wire between the two pins of the AC Power plug.2. S
21、et the AC Power switch to the “on“ position (keep theAC Power cord unplugged!).3. Measure the resistance value between the pins of the AC Power plug and the metal shielding of the tuner or the aerial connection on the set. The reading should be larger than 4.5 Mohm (For U.S. it should be between 4.2
22、 Mohm and 12 Mohm).4. Switch “off“ the set, and remove the wire between the two pins of the AC Power plug.Safety regulations require that after a repair, the set must be returned in its original condition. Pay in particular attention tothe following points: Route the wire trees correctly and fix the
23、m with themounted cable clamps. Check the insulation of the AC Power lead for externaldamage. Check the strain relief of the AC Power cord for proper function. Check the electrical DC resistance between the AC PowerPlug and the secondary side (only for sets which have a ACPower isolated power supply