1、Color Television ChassisFR970/171931ServiceServiceServiceServiceManualContents Contents4. Mechanical Instructions 00 6. Block Diagrams and Testpoints 00 7. Electrical Diagrams and PWBs Diagram PWBWIRING DIAGRAM 1 0 FRONT PANEL leakage current must not exceed 0.5milliamp. If a measurement is outside
2、of thespecified limits, there is a possibility of shock hazard. The receiver should be repaired and recheckedbefore returning it to the customer.5. Repeat the above procedure with the ac plug reversed. (Note: An ac adapter isnecessary when a polarized plug is used. Do not defeat the polarizing featu
3、re of the plug.)ORWith the instrument completely reassembled, plug the AC line cord directly into a 120V AC outlet. (Donot use an isolation transformer during this test.) Use a leakage current tester or ametering system that complies with American National Standards Institute (ANSI) C101.1 LeakageCu
4、rrent for Appliances and Underwriters Laboratories (UL) 1410, (50.7). With the instrumentAC switch first in the on position and then in the off position, measure from aknown earth ground (metal water pipe, conduit, etc.) to all exposed metalparts of the instrument (antennas, handle brackets, metal c
5、abinet, screwheads, metallic overlays, control shafts, etc.), especially any exposed metalparts that offer an electrical return path to the chassis. Any currentmeasured must not exceed 0.5 milliamp. Reverse the instrument power cordplug in the outlet and repeat the test. See graphic below.PICTURE TU
6、BE REPLACEMENTThe primary source of X-radiation in this television receiver is the picture tube. The picture tube utilizedin this chassis is specially constructed to limit X-radiation emissions. For continued X-radiationprotection, the replacement tube must be the same type as the original, includin
7、g suffix letter, or aPhilips approved type.PARTS REPLACEMENTMany electrical and mechanical parts in Philips television sets have special safety related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded bythem necessarily be obtained b
8、y using replacement components rated for higher voltage, wattage, etc. The use of a substitute part which does not have the same safety characteristics as the Philipsrecommended replacement part shown in this service manual may create shock, fire, or other hazardsTV SAFETY NOTESSAFETY CHECKSIMPLOSIO
9、N X-RADIATIONPICTURE TUBE REPLACEMENT PARTS REPLACEMENT WARNINGBefore removing the CRT anode cap, turn the unit OFF and short the HIGH VOLTAGE to the CRT DAGground.SERVICE NOTE: The CRT DAG is not at chassis ground.TV-VCR COMBI SAFETY NOTESIMPORTANT SAFETY PRECAUTIONSPrior to shipment from the facto
10、ry, our products are strictly inspected for recognized product safety andelectrical codes of the countries in which they are to be sold. However, in order to maintain suchcompliance, it is equally important to implement the following precautions when a set is being serviced.SAFETY PRECAUTIONS FOR TV
11、 CIRCUITS1. Before returning an instrument to the customer, always make a safety check of the entire instrument,including, but not limited to, the following items:a. Be sure that no built-in protective devices are defective or have been defeated during servicing.(1) Protective shields are provided o
12、n this chassis to protect both the technician and the customer. Correctly replace all missing protective shields, including any removed for servicing convenience. (2)When reinstalling the chassis and/or other assembly in the cabinet, be sure to put back in place allprotective devices, including but
13、not limited to, nonmetallic control knobs, insulating fishpapers,adjustment and compartment covers/shields, and isolation resistor/capacitor networks. Do notoperate this instrument or permit it to be operated without all protective devices correctly installedand functioning. Servicers who defeat saf
14、ety features or fail to perform safety checks may be liablefor any resulting damage.b. Be sure that there are no cabinet openings through which an adult or child might be able to inserttheir fingers and contact a hazardous voltage. Such openings include, but are not limited to, (1)spacing between th
15、e picture tube and the cabinet mask, (2) excessively wide cabinet ventilation slots,and (3) an improperly fitted and/or incorrectly secured cabinet back cover.c. Do a LEAKAGE CURRENT CHECK ANY MEASUREMENTS NOT WITHIN THE LIMITS SPECIFIED HEREIN INDICATE A POTENTIAL SHOCKHAZARD THAT MUST BE ELIMINATE
16、D BEFORE RETURNING THE INSTRUMENT TO THE CUSTOMEROR BEFORE CONNECTING THE ANTENNA OR ACCESSORIES.d. X-Radiation and High Voltage Limits - Because the picture tube is the primary potentialsource of X-radiation in solid-state TV receivers, it is specially constructed to prohibit X-radiationemissions.
17、For continued X-radiation protection, the replacement picture tube must be the same typeas the original. Also, because the picture tube shields and mounting hardware perform an X-radiationprotection function, they must be correctly in place. High voltage must be measured each timeservicing is perfor