1、GBCLASS 1LASER PRODUCTCOMPACTDIGITAL AUDIOService ManualServiceServiceServiceFW-C505/21/22TABLE OF CONTENTSPageLocation of pc boards fr Reparaturen sind Original-Ersatzteile zu verwenden.ILe norme di sicurezza esigono che lapparecchio venga rimessonelle condizioni originali e che siano utilizzati i
2、pezzi di ricambioidentici a quelli specificati.“After servicing and before returning set to customer perform aleakage current measurement test from all exposed metal parts toearth ground to assure no shock hazard exist. The leakage currentmust not exceed 0.5mA.“CLASS 1LASER PRODUCT3122 110 03420GB W
3、arning !Invisible laser radiation when open.Avoid direct exposure to beam.S Varning !Osynlig laserstrlning nr apparaten r ppnad och sprrenr urkopplad. Betrakta ej strlen.SF Varoitus !Avatussa laitteessa ja suojalukituksen ohitettaessa olet alttiinankymttmlle laseristeilylle. l katso steeseen!DK Adva
4、rse !Usynlig laserstrling ved bning nr sikkerhedsafbrydere erude af funktion. Undg udsaettelse for strling.1-63. Lift up and out1. Place screw driver(flat side) betweenthe cassette cover& cassette door2. Twist screw driverDISMANTLING INSTRUCTIONSDismantling of the Cassette Cover1) Loosen 4 screws to
5、 remove the Cover Top (pos 255) of theset.2) Loosen 3 screws to remove the Panel Left (pos 253) and3 screws to remove the Panel Right (pos 254) of the set.3) Slide out the CDC Tray as shown in the diagram below withthe help of a flat head screw driver.Cassette CoverRemove Cassette CoverDismantling o
6、f the CDC Module and Front Panel AssemblyRemove CDC Module4) Remove the Cover Tray CDC (pos 106) as indicated.Front View CDCRemove Cover Tray CDCDismantling of the CDC Module and Front Panel AssemblySliding out the CDC Tray5) Loosen 2 screws A and 2 screws B to remove the CDCModule (pos 1105) as ind
7、icated.6) Remove 2 screws (pos 226) at the bottom to separate theFront Panel Assembly from the Plate Bottom (pos 265).2-1 2-12-2 2-2Dismantling of the ETF Tape Module1) Remove 6 screws G as indicated to loosen the ETF TapeModule (pos 1104).Dismantling of the Rear PortionDismantling of the Front Disp
8、lay Board and Front Control Board1) Remove 1 screw C as indicated to loosen the HeadphoneBoard (pos 1101-B).2) Remove 5 screws D as indicated to loosen the FrontDisplay Board (pos 1101-A).3) Remove 9 screws E as indicated to loosen the FrontControl Board (pos 1107-A).4) Remove 1 screw F as indicated
9、 to loosen the IR-EyeBoard (pos 1107-D).5) Remove 3 screws N as indicated to loosen the VU MeterBoard (pos 1107-C).1) The Knob Volume Black (pos 117) can be remove byinserting a strong string into the slot and pull it out in thedirection as indicated. See picture 1.2) The Knob Jog Rotary (pos 140) c
10、an be remove byinserting a strong string into the slot and pull it out in thedirection as indicated. See picture 2.Picture 1Picture 2Repair Hints1) Remove 1 screw J and uncatch M1 as indicated to loosenthe AF Board (pos 1102-A).2) Remove 3 screws K and uncatch M2 as indicated toloosen the Tuner Boar
11、d (pos 1103).3) Remove 4 screws L as indicated to loosen the PanelRear (pos 256).Remove AF BoardRemove VU Meter BoardRemove Front Display Board and Headphone BoardRemove Front Control Board and IR-Eye Board2-3 2-3Service position DService position AService position CRepair Hints3) During repair it i
12、s possible to disconnect the Tuner boardand CDC Module completely unless the fault is sus-pected to be in that area. This will not affect theperformance of the rest of the set.4) Due to the short flex cable wires in the ETF Module, thepc board should be disconnected and reconnected onthe reverse sid
13、e of the tape mechanism to keep itelectrically connected during repair. See picture 3.Note: The flex cables are very fragile, care should be takennot to damage them during repair. After repair, bevery sure that the flex cables are inserted properlyinto the flex sockets before encasing, otherwise fau
14、ltsmay occurs.Picture 3Service position BTable 2Error codeE1000E1001E1002E1003E1005E1006E1007E1008E1020E1070E1071E1079Error DescriptionFocus ErrorTriggered when the focus could not be found within a certain time when starting up the CDor when the focus is lost for a certain time during play.Radial E
15、rrorTriggered when the radial servo is off-track for a certain time during play.Sledge In ErrorThe sledge did not reach its inner position (inner-switch is still close) before approximately6 Sec. have passed by. Inner-switch or sledge motor problem.Sledge Out ErrorThe sledge did not come out of its