Philips-CEM-2000-B-Service-Manual电路原理图.pdf
《Philips-CEM-2000-B-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-CEM-2000-B-Service-Manual电路原理图.pdf(72页珍藏版)》请在收音机爱好者资料库上搜索。
1、Version 1.1CEM2000/00/55/513141 785 35131Car entertainment systemCEM2000X/78Published by LX 1046 Service Audio Subject to modificationCopyright 2010 Philips Consumer Electronics B.V. Eindhoven, The NetherlandsAll rights reserved. No part of this publication may be reproduced, stored in a retrievalsy
2、stem or transmitted, in any form or by any means, electronic, mechanical, photocopying,or otherwise without the prior permission of Philips.CONTENTSTechnical specification .1-2Service measurement setup.1-3Service aids .1-4Instructions on CD playability .2-1. 2-2Block diagram .3-1Wiring diagram .4-1
3、Main boardCircuit diagram .5-1.5-5Layout diagram.5-6.5-7Panel boardCircuit diagram .6-1Layout diagram.6-2.6-3Servo boardCircuit diagram.7-1Layout diagram .7-2.7-3Exploded view diagram .8-1Revision list .9-1TECHNICAL SPECIFICATION1 - 2Power supply 12 V DC (11 V - 16 V), negative groundFuse 15 ASuitab
4、le speaker impedance4 - 8 Maximum power output45 W x 4 channelsContinuous power output22 W x 4 RMS (410% T.H.D.)Pre-Amp output voltage2.0 VAux-in level 500 mVDimensions (W x H x D) 188 x 58 x 201 mmWeight 1.47 kgRadioFrequency range - FM87.5 - 108.0 MHz (100kHz per step in auto search and 50kHz per
5、step in manual search)Frequency range - AM(MW)522 - 1620 KHz (9 kHz)530 - 1710 kHz (10 kHz)Usable sensitivity - FM8 VUsable sensitivity - AM(MW) (S/N = 20 dB)30 VGeneral inforamtionType /Versions:FeaturesBoard in used:CEM2000Service policySERVO BOARDMAIN BOARD* TIPS : C - Component Lever Repair.M -
6、Module Lever Repair- Used/00 /00/55 15/16/85/Feature diffrenceRDSVOLTAGE SELECTORECO STANDBY - DARKC/MC/MType /Versions:CEM2000/05 /12 /5515/16/85/VERSION VARIATIONC/MC/MCCEurope APACCC1-3LF Generator e.g. PM5110RecorderUse Universal Test Cassette CrO2 SBC419 4822 397 30069LEVEL METERe.g. Sennheiser
7、 UPM550with FF-filterS/N and distortion metee.g. Sound Technology ST170LRDUTor Universal Test Cassette Fe SBC420 4822 397 30071LEVEL METERe.g. Sennheiser UPM550with FF-filterS/N and distortion metere.g. Sound Technology ST1700BLRDUTCDUse Audio Signal Disc(replaces test disc 3)SBC429 4822 397 30184Ba
8、ndpass250Hz-15kHze.g. 7122 707 48001LF Voltmetere.g. PM2534DUTS/N and distortion metere.g. Sound Technology ST1700BFrame aeriale.g. 7122 707 89001Tuner AM (MW,LW)To avoid atmospheric interference all AM-measurements have to be carried out in a Faradays cage.Use a bandpass filter (or at least a high
9、pass filter with 250Hz) to eliminate hum (50Hz, 100Hz).RF Generator e.g. PM5326Ri=50:Bandpass250Hz-15kHze.g. 7122 707 48001LF Voltmetere.g. PM2534DUTRF Generator e.g. PM5326S/N and distortion metere.g. Sound Technology ST1700BUse a bandpass filter to eliminate hum (50Hz, 100Hz) and disturbance from
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- PhilipsCEM2000BServiceManual 电路 原理图