Philips-BDP-2305-Service-Manual电路原理图.pdf
《Philips-BDP-2305-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Philips-BDP-2305-Service-Manual电路原理图.pdf(49页珍藏版)》请在收音机爱好者资料库上搜索。
1、Version 1.2 Blu-ray PlayerPublished by Niki Conform to Directive 2005/32/EC (Commission Regulation EC No. 1275/2008). In addition, the player must conform to the following requirement. Function Requirement 1. Standby -52 dB suppression of the disturbance with regard to the rated output voltage. The
2、peak level has to be measured according to IEC 60651 weighted (A) curve. 2-11.5 Additional Requirements for India 1.5.1 VoltageRange Check The set should work NORMALLY at mains voltage from 170V to 280V AC. (Incases of set with Audio amplifiers, at lower mains voltages, audio rated poweroutput might
3、 be lower against the specified power at nominal mains voltage, butremaining performance should be unaffected). 1.5.2 Soak Test The set should be tested in ON condition with full loaded condition (MaximumAudio Power Output in case of set with Audio Amplifiers) at mains voltage of 280VAC, for 4 hours
4、. 1.5.3 310V AC Test The set should be connected to 310V AC in Standby condition for 4 hours. Setshould work NORMALLY after the test. 1.5.4 Immunity to Electrical Surge from External Devices (For India & ALL other Regions) The product shall withstand Surge from external devices (e.g. TV) cinch conne
5、ctors into ALL video outputs without damaging any electrical component (e.g. MPEG IC) All products shall have surge protection implemented for all Video Output terminals. Test Condition: 1. Refer to ESD test setup and test condition to simulate the surge from external devices. 2. Contact Discharge t
6、o signal pin of cinch socket with below modified cinch connector jig to tap out the signal line. Requirement: For India: Set must be able to withstand up to 25kV contact discharge without any component damage. For All Other Regions: Set must be able to withstand up to 15kV contact discharge without
7、any component damage. 1.5.5 Immunity to DC Voltages from External Devices at CVBS Terminal (For India Only) The CVBS video output must be DC isolated from external devices (e.g. TV and RF Modulators). 2-22 Mechanical Specifications 2.1 Mechanical Strength and Ease of Control 2.1.1 Mechanical Strengt
8、h Set exterior parts such as lens, buttonsetc, shall be able to withstand a force of 50N during 30 seconds from all possible directions. The rigid test finger, according to IEC60065 clause: 9.1.8 should be used. Set shall be proof against a pinch force of 150N, loaded by a bare hand. The product sha
9、ll give a rigid impression and shall not produce any annoying mechanical noise. 2.1.2 Rigidity of Top Surface Set top must be able to withstand a force of 100N for duration of at least 30 seconds. This force has to be applied by means of a flat plane of 4cm2(a plane with dimensions of 2cm x 2cm) at
10、all places at the top side. 2.1.3 Regularity of Operating Forces for Touch Control Deviations in the regularity of the operating force of touch control shall not be perceptible by hand. 2.1.4 Moving of Set during Operation Set shall not move (slide backwards) whilst operating the touch control on th
11、e set or inserting disc. 2.1.5 Maximum Temperatures The maximum permissible temperature rises of the various external parts of a product are mentioned in the next table. The values of the temperature are based upon the maximum ambient temperature of 35C. The temperatures have to be measured after an
12、 operation time of 4 hours. Maximum temperature rises with respect to the max ambient temperature. External Product Parts Maximum Temperature Rise (C) Metallic Parts: -front part of enclosure 10 -other parts of enclosure 25 Non-metallic Parts: -enclosure 302.2 Detachable Mains Cord & Connector Socke
13、ts 2.2.1 Connector / Socket a) Cinch sockets need to withstand a force of at least 100N in insertion and withdrawal directions and 50N parallel to the set surface at 2cm distance. b) If the connector socket is mounted directly on the PCB, the solder points have to be relieved mechanically. c) Connec
14、tor / socket have to withstand the following minimal insertions and withdrawals, USBPort: 1500 Other connectors: 500 2-32.2.2 NA a) Detachable mains cord inlet has to withstand minimal 2500 insertions and withdrawals. b) Mains cord operating force should be within the following limits: Withdrawal Fo
15、rce, P: 10N P 50N Insertion Force, F: F 50N 2.3 Visibility of User Interface Displays & Indicators NA 2.3.1 Viewing Angle The visibility of display is possible under a viewing angle of 30from Top, Bottom, Left and Right. Note: Viewing angle with regard to the perpendicular at the front of the appara
16、tus. 2.3.2 Display illumination The display / segment illumination should be uniform without undesirable light concentrations. 2.3.3 Brightness As per reference. BDP2100. 2.3.4 Light Leakage No light leakage is allowed (e.g. at connector sockets). Above to be judge in dark condition to a bright cond
17、ition of 600-800 lux 2.4 Screw Fixations The screw fixations have to be designed in such a way, that after 10 times screwing and unscrewing, no decrease of the quality of the fixation occurs. The dimensions of thermoplastic bosses, intended for screw-fixations, have to be designed in such a way that
18、 no deterioration of the fixation can take place, taken into account the environment conditions. 2.5 Support Foot 2.5.1 Type of material Refer to MUS 3 for the type of material used. 1. Material for the support foot cannot shrunk in such a degree, e.g. after the Cyclic Humidity Test of 21 x 24 hours
19、, that the set touches the furniture or other equipment during shifting. Minimum of 1mm height should still be attained. 2. Material of the support foot cannot leave stains on furniture surfaces after climatic tests e.g. 70deg x 96hr. 3. The support foots shall prevent the set from moving over the u
20、nderneath surface while normally operating the set. 2-42.6 Touch Control Criteria NA 2.7 Bezel and Tray loader design 2.7.1 Strength Permissible load on Bezel in any direction is 50N.The Tray & Bezel should not be broken or permanently deformed, nor cause damage to other parts of set. The Bezel may
21、dislodge above 30N without suffering any damage, and the user must be able to easily put the Bezel back. Dislodge of the Bezel shall not cause damage to the set. 2.7.2 Actuating force needed for Tray Force needed to actuate the tray should be 5N. 2.7.3 Tray Movement Cycle (Life Test) 24,000 open / c