1、ServiceManual Some illustrations using in this service manual are slightly different from the actual set. Please use this service manual with referring to the operating instructions without fail. For purposes of improvement, specifications and design are subject to change without notice.AV Pre Tuner
2、AV7005 / N1B/U1BAV7005AV7005S0195-1V03DM/DG1011 Copyright 2010 DoM3SAFETY PRECAUTIONSThe following check should be performed for the continued protection of the customer and service technician.LEAKAGE CURRENT CHECKBefore returning the unit to the customer, make sure you make either (1) a leakage cur
3、rent check or (2) a line to chassis resistance check. if the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.Be sure to test for leakage current with the AC plug in both polarities, in addition, i
4、n each power ON, OFF and STANDBY mode, if applicable.CAUTIONPlease heed the points listed below during servicing and inspection.Heed the cautions!Spots requiring particular attention when servicing, such as the cabinet, parts, chassis,etc., have cautions indicated on labels. be sure to heed these ca
5、usions and the cautions indicated in the handling instructions.Caution concerning electric shock!(1) An AC voltage is impressed on this set, so touching internal metal parts when the set is energized could cause electric shock. Take care to avoid electric shock, by for example using an isolating tra
6、nsformer and gloves when servicing while the set is energized, unplugging the power cord when replacing parts, etc.(2) Tere are high voltage parts inside. Handle with extra care when the set is energized. Caution concerning disassembly and assembly!Through great care is taken when manufacturing part
7、s from sheet metal, there may in some rare cases be burrs on the edges of parts which could cause injury if fi ngers are moved across them. Use gloves to protect your hands.Only use designated parts!The sets parts have specific safety properties (fire resistance, voltage resistance, etc.). For repla
8、cement parts, be sure to use parts which have the same poroperties. In particular, for the important safety parts that are marked z on wiring diagrams and parts lists, be sure to use the designated parts. Be sure to mount parts and arrange the wires as they were originally!For safety seasons, some p
9、arts use tape, tubes or other insulating materials, and some parts are mounted away from the surface of printed circuit boards. Care is also taken with the positions of the wores omsode amd clamps are used to keep wires away from heating and high voltage parts, so be sure to set everything back as i
10、t was originally.Inspect for safety after servicing!Check that all screws, parts and wires removed or disconnected for servicing have been put back in their original positions, inspect that no parts around the area that has been serviced have been negatively affected, conduct an inslation check on t
11、he external metal connectors and between the blades of the power plug, and otherwise check that safety is ensured.(Insulation check procedure)Unplug the power cord from the power outlet, disconnect the antenna, plugs, etc., and turn the power switch on. Using a 500V insulation resistance tester, che
12、ck that the inplug and the externally exposed metal parts (antenna terminal, headphones terminal, input terminal, etc.) is 1M or greater. If it is less, the set must be inspected and repaired.Many of the electric and structural parts used in the set have special safety properties. In most cases thes
13、e properties are difficult to distinguish by sight, and using replacement parts with higher ratings (rated power and withstand voltage) does not necessarily guarantee that safety performance will be poreserved. Parts with safety properties are indicated as shown below on the wiring diagrams and part
14、s lists is this service manual. Be sure to replace them with parts with the designated part number.(1) Schematic diagrams .Indicated by the z mark.(2) Parts lists .Indicated by the z mark.Using parts other than the designated parts could result in electric shock, fi res or other dangerous situations
15、.CAUTIONConcerning important safety parts4NOTE FOR SCHEMATIC DIAGRAMWARNING:Parts marked with this symbol z have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.CAUTION:Before returning the unit to the customer, make sure you make either (1) a leakage current che
16、ck or (2) a line to chassis resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.WARNING:DO NOT return the unit to the customer until the problem is located and corrected.NOTIC
17、E:ALL RESISTANCE VALUES IN OHM. k=1,000 OHM / M=1,000,000 OHMALL CAPACITANCE VALUES IN MICRO FARAD. P=MICRO-MICRO FARAD EACH VOLTAGE AND CURRENT ARE MEASURED AT NO SIGNAL INPUT CONDITION. CIRCUIT AND PARTS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE.Parts for which “nsp“ is indicated on this table ca
18、nnot be supplied.When ordering of part, clearly indicate “1“ and “I“ (i) to avoid mis-supplying.Ordering part without stating its part number can not be supplied. Not including General-purpose Carbon Chip Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)Parts ma
19、rked with this symbol z have critical characteristics. Use ONLY replacement parts recommended by the manufacturer.Not including General-purpose Carbon Film Resistor in the P.W.Board parts list. (Refer to the Schematic Diagram for those parts.)Part indicated with the mark “ “ is not illustrated in th
20、e exploded view.WARNING:1.2.3.4.5.6. ResistorsRD : CarbonRC : CompositionRS : Metal oxide filmRW: windingRN : Metal filmRK : Metal mixtureP : Pulse-resistant typeNL : Low noise typeNB : Non-burning typeFR : Fuse-resistorF : Lead wire forming2B : 1/8 W2E : 1/4 W2H : 1/2 W3A : 1 W3D : 2 W3F : 3 W3H :
21、5 WF:1%G:2%J:5%K:10%M:20%Ex.: RNType14KShapeand per-formance2EPower182Resist-anceGAllowableerrorFROthers Resistance1800ohm=1.8kohm1 8 2Indicates number of zeros after effective number.2-digit effective number.1.2ohm1 R 22-digit effective number, decimal point indicated by R.1-digit effective number.
22、: Units: ohm CapacitorsCE : Aluminum foilelectrolyticCA : Aluminium solidelectrolyticCS : Tantalum electrolyticCQ: FilmCK : CeramicCC : CeramicCP : OilCM: MicaCF : MetallizedCH : MetallizedHS : High stability typeBP : Non-polar typeHR : Ripple-resistant typeDL : For change and dischargeHF : For assu