1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB3382004/12MICRO COMPONENT SYSTEMMB338200412UX-QD9STABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPEC
2、IFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 AD
3、JUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-285 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . 1-32(CA-UXQD9S) (SP-UXQD9S)(SP-UXQD9S)Area suffixA - AustraliaUS - SingaporeUN - Asean1-2 (No.MB338)SPECIFICATIONDVD receiver (CA-UXQD9S)Speaker (SP-UXQD9S)Micro component system (UX-QD9S) U.S. and foreign patents licensed from Dolby Laboratories. Design and specifications are subject to change w
5、ithout notice.Amplifier Output power 20 W + 20 W at 4 (10% THD)Input terminals Analog AUX1,500 mV/47 k:LEVEL1250 mV/47 k:LEVEL2Output terminals Analog Speaker1, 20 W/4 , Impedance 4 - 16 Headphone (1), 25 mW/32 , Impedance 16 - 1 kDigital DVD/CD optical input 1-23 dBm to -15 dBm (Optical square term
6、inal)Other AV COMPU LINK 2 ( 3.5)Tuner Frequency FM 87.50 MHz - 108.00 MHzAM 531 kHz - 1 710 kHz (9 kHz spacing)530 kHz - 1 710 kHz (10 kHz spacing)DVD player Playable discs DVD VIDEO, DVD AUDIO, CD, VCD, SVCD, CD-R/CDRW (CD, VCD, SVCD, MP3/ WMA/JPEG format), DVD-R/ DVD-RW (video format)Cassette dec
7、k Frequency response Normal (type I) 60 Hz - 14 000 HzWow and flutter 0.15% (WRMS)General Power requirement AC 240 V , 50/60 Hz (UN,US only)AC 240 V , 50 Hz (A only)Power consumption 70 W (at operation) 1.3 W (on standby)Dimensions 165 mm (W) 200 mm (H) 355 mm (D)Mass (approx.) 4.6 kgSystem 3-way ba
8、ss reflex type, Magnetically shielded typeSpeakers Woofer 10 cm 1Midrange 4 cm 1Tweeter 1.5 cm 1Power handling capacity 20 WImpedance 4 Frequency range 55 Hz - 40 kHzSound pressure level 85 dB/WmDimensions 140 mm (W) 231 mm (H) 204.5 mm (D)Mass (approx.) 2.2 kg (1 unit)General Dimensions 445 mm (W)
9、231 mm (H) 355 mm (D)Mass (approx.) 9.0 kg(No.MB338)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless a
10、uthorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot b
11、e made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. The
12、se characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List
13、of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts
14、List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehaz
15、ard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of
16、 the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“L
17、eakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord
18、directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvo
19、ltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.
20、m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the
21、relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such b
22、urrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “
23、 “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or mo
24、re sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB338)1.5 Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fabric, etc. is discharged, can destroy the laserdiode in the traverse unit (optical pickup). Take care to prevent this when per