1、SERVICE MANUALCOPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB0662004/1MICRO COMPONENT SYSTEMMB06620041UX-H10TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFI
2、C SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64 ADJUS
3、TMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-125 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、1-16TIMER SETRANDOM SLEEPINTROSTANDBY/ONTIMERON/OFFREMAINBEAT CUTDISPLAY/CLOCK SETMUTINGRM-SUXH10U REMOTE CONTROLSOUND/BASSCDTAPE CDVOLUMETUNER/BANDREPEATST/MONOPROGRAMSTANDBY/ONSTANDBYOPENVOLUMEMICRO COMPONENT SYSTEMUX-H10CD SYNCHRO RECORDINGArea SuffixUS - SingaporeUT -TaiwanUW - Brazil,Mexico,Per
5、u1-2 (No.MB066)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier SectionCA-UXH10Output Power (IEC 268-3) 10 W (5 W + 5 W) at 4 (10% THD)Speakers/Impedance 4 - 16 Tuner FM tuning range 87.50 MHz-108.00 MHzAM tuning range AM 10 kHz intervals 530 kHz- 1 710 kHzAM 9 k
6、Hz intervals 531 kHz-1 710 kHzCD player Dynamic range 60 dBSignal-to-noise ratio 60 dBWow and flutter ImmeasurableCassette deck Frequency response Normal (type I) 100 Hz-10 000 HzWow and flutter 0.35 % (WRMS)General Power requirement AC 110 V-127 V/ 220 V-240 V , adjustable with the voltage selector
7、, 50 Hz/ 60 HzPower consumption 22 W (at operation)4.5 W (on standby)Dimensions (W/H/D) (approx.) 145 mm 209 mm 226 mmMass (approx.) 2.6 kgSpeaker SectionSP-UXH10Type Full range bass-reflex typeSpeakers 10 cm cone x1Power handling capacity 5 WImpedance 4 Frequency range 100 Hz to 15 kHzDimensions (W
8、/H/D) (approx.) 135 mm 209 mm 152 mmMass (approx.) 1.3 kg each(No.MB066)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the orig
9、inal design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the
10、 product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related
11、characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identifie
12、d in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement part
13、s shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electr
14、ic shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the ex
15、posed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the
16、AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPl
17、ug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the re
18、sistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot
19、exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in
20、accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay
21、 attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or