Jvc-UXG-300-Service-Manual电路原理图.pdf
《Jvc-UXG-300-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXG-300-Service-Manual电路原理图.pdf(59页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2008 Victor Company of Japan, LimitedNo.MB6652008/9MICRO COMPONENT SYSTEMMB66520089SERVICE MANUALUX-G300B, UX-G300E, UX-G300EN, UX-G300EV, UX-G303E, UX-G303EN, UX-G303EV, UX-G305E, UX-G305EN, UX-G305EV, UX-G300A, UX-G300US, UX-G300UF, UX-G300UT, UX-G300UW, UX-G300UG, UX-G300U
2、N, UX-G305UTCOPYRIGHT 2008 Victor Company of Japan, LimitedLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)Lead free solder used in the board (material : Sn-Cu, melting point : 230 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-205 TROUBLESHOOTING . . . . . .
5、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-21UX-G300EVUX-G303EVUX-G305EVSP-UXG300SP-UXG300CA-UXG3001-2 (No.MB665)SPECIFICATIONUX-G300 B/E/EN/EVUX-G303 E/EN/EVUX-G305 E/EN/EVSpecifications and appearance are subject to chan
6、ge without prior notice.Amplifier sectionOUTPUT POWER 60 W (30 W + 30 W) at 4 (10% THD)Speakers/Impedance 4 - 16 Audio input AUDIO IN 500 mV/47 k (at “IN LVL1”)250 mV/47 k (at “IN LVL2”)125 mV/47 k (at “IN LVL3”)Digital input USB MEMORYTuner sectionFM tuning range 87.50 MHz - 108.00 MHzAM (MW) tunin
7、g range 522 kHz - 1 629 kHzCD player sectionDynamic range 88 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableUSB storageUSB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible file system “FAT16,FAT32“Bus power supply Max. 500 mASpeakersSpeaker uni
8、ts 10 cm cone x 1Impedance 4 Dimensions (approx.) 160 mm x 250 mm x 150 mm (W/H/D)Mass (approx.) 1.6 kg eachGeneralPower requirements “AC 230,50 Hz“Power supply to USB mass storage class device DC 5 V =500 mAPower consumption 20 W (power on)6.5 W (standby mode)1 W or less (Save Mode)Dimensions (W x
9、H x D) 165 mm x 251 mm x 269 mmMass 2.6 kg(No.MB665)1-3UX-G300 US/UN/UB/UG/A/UW/UF/UTUX-G305UTSpecifications and appearance are subject to change without prior notice.Amplifier sectionOUTPUT POWER 60 W (30 W + 30 W) at 4 (10% THD)Speakers/Impedance 4 - 16 Audio input AUDIO IN 500 mV/47 k (at “IN LVL
10、1”)250 mV/47 k (at “IN LVL2”)125 mV/47 k (at “IN LVL3”)Digital input USB MEMORYTuner sectionFM tuning range 87.50 MHz - 108.00 MHzAM (MW) tuning range 530 kHz - 1 710 kHz (in 10 kHz spacing)531 kHz - 1 710 kHz (in 9 kHz spacing)CD player sectionDynamic range 88 dBSignal-to-noise ratio 85 dBWow and f
11、lutter ImmeasurableUSB storageUSB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible file system FAT16, FAT32Bus power supply Max. 500 mASpeakersSpeaker units 10 cm cone x 1Impedance 4 Dimensions (approx.) 160 mm x 250 mm x 150 mm (W/H/D)Mass (approx.) 1.6
12、 kg eachGeneralPower requirements AC 110 V - AC 240 V , 50/60 HzAC 240 V , 50 Hz (only Australia)AC 220 V , 50 Hz (only Hong Kong)Power supply to USB mass storage class device DC 5 V =500 mAPower consumption 20 W (power on)6.5 W (standby mode)1 W or less (Save Mode)Dimensions (W x H x D) 165 mm x 25
13、1 mm x 269 mmMass 2.6 kg1-4 (No.MB665)SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writ
14、ing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any desig
15、n alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-ti
16、cs are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manua
17、l. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service M
18、anual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service
19、 is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-
20、tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Te
21、ster“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the
22、 AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the