Jvc-UXP-55-Service-Manual电路原理图.pdf
《Jvc-UXP-55-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXP-55-Service-Manual电路原理图.pdf(42页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LTD.No.220362003/4MICRO COMPONENT SYSTEM2203620034UX-P55TABLE OF CONTENTS1 Important Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Disassembly metho
2、d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . 194 Description of major ICs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25CA-UXP55 SP-UXP55COMPACTDIGITAL AUDIOCD TAPE FM/AMMICRO COMPONENT SYSTEM UXP55CD-R/RW PLAYBACKMD/AUXTIMERCLOCKSTANDBY / ONSTANDBY / ONVOL
4、UMEFUNCTIONSOUNDDIRECT OPERATINGAHB PROREV.MODEPHONES AUTO REVERSEREC/RECSLEEPSTANDBY/ONMD/AUXFM/AMTAPECDDISPLAYDIMMERREPEATRANDOMPROGFM MODEAUTOPRESETSOUNDMODECDCANCEL MULTI KEY SETPTY/EONDISPLAYMODERM-SUXP5R REMOTE CONTROLVOLUMEAHBPROSP-UXP55B - U.K.E - Continental EuropeEN - Norther EuropeArea Su
5、ffix1-2 (No.22036)SECTION 1Important Safety Precautions1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writin
6、g by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design
7、alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics
8、 are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual.
9、 Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Man
10、ual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service i
11、s required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testing)After reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-t
12、enna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tes
13、ter“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the
14、AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the
15、resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corres
16、ponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety sta
17、ndards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case o
18、f pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are
19、 criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)150
20、0 10W0.15 F AC TYPE(No.22036)1-31.5 Safety Precautions (U.K only)(1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For con-tinued protection, no changes should be made to the original design unless authorized in writing by the m
21、anufacturer. Replace-ment parts must be identical to those used in the original circuits.(2) Any unauthorised design alterations or additions will void the manufacturers guarantee; furthermore the manufacturer cannotaccept responsibility for personal injury or property damage resulting therefrom.(3)
22、 Essential safety critical components are identified by ( ) on the Parts List and by shading on the schematics, and must neverbe replaced by parts other than those listed in the manual. Please note however that many electrical and mechanical parts inthe product have special safety related characteri
23、stics. These characteristics are often not evident from visual inspection. Partsother than specified by the manufacturer may not have the same safety characteristics as the recommended replacement partsshown in the Parts List of the Service Manual and may create shock, fire, or other hazards.(4) The
24、 leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separated from live parts,high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service isrequired, the original lead routing and dress s
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcUXP55ServiceManual 电路 原理图