Jvc-THC-9-Service-Manual电路原理图.pdf
《Jvc-THC-9-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-THC-9-Service-Manual电路原理图.pdf(91页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4272005/8DVD DIGITAL CINEMA SYSTEMMB42720058TH-C9Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-385 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43Area suffixUS - SingaporeUT - TaiwanUX - Saudi ArabiaUG - Turkey,South Africa,EgyptUN - Asean(XV-THC9)(SP-PWC9)(SP-THC9C)(SP-THC9F) (SP-THC9F) (SP-THC9S)1-2 (No.MB427)SPECIFICATIONCenter unit-XV-THC9*1: Thi
5、s value is measured at System cord CONNECTOR for reference.*2: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz)Subwoofer-SP-PWC9Audio section Total Harmonic Distortion *1 0.02%Digital input*2 DIGITAL IN (DBS): -21 dBm to -15 dBm
6、(OPTICAL): (660 nm 30 nm)Video section Video System PAL/NTSCHorizontal Resolution 500 linesSignal-to-Noise Ratio 64 dBVideo output level Composite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Component-Y: 1.0 V(p-p)/75 Component-PB/PR
7、: 0.7 V(p-p)/75 Video input sensitivity/Impedance (VCR IN) Composite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Tuner section Tuning Range FM 87.5 MHz to 108.0 MHzAM (Except for Middle East) 531 kHz to 1 710 kHz(at 9 kHz channel spa
8、cing)530 kHz to 1 710 kHz(at 10 kHz channel spacing)AM (For Middle East) 531 kHz to 1 602 kHz(at 9 kHz channel spacing)530 kHz to 1 600 kHz(at 10 kHz channel spacing)General Power Requirements AC 110-240 V , 50/60 HzPower Consumption 19 W (at operation)1.9 W (in standby mode)Dimensions (W H D) 400 m
9、m 85 mm 399 mmMass 4.2 kgAmplifier section Front/Center/Surround 140 W per channel, RMS at 4 at 1 kHz, with 10% total harmonic distortion.Subwoofer 300 W, RMS at 4 at 40 Hz, with 10% total harmonic distortion.Speaker section Speaker unit 25 cm Bass-reflexPower Handling Capacity 300 WImpedance 4 Freq
10、uency Range 25 Hz to 200 HzGeneral Power Requirements AC 110 V/ AC 127 V/AC 220-240 V , 50/60 HzPower Consumption 110 W (at operation)0 W (in standby mode)Dimensions (W H D) 264 mm 481 mm 459 mmMass 17.6 kg(No.MB427)1-3Satellite Speaker-SP-XTHC9Designs & specifications are subject to change without
11、notice.Front speakers (SP-THC9F) Speaker unit Woofer 10.0 cm 2Midrange 10.0 cm 2Tweeter 4 cmBass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance 4 Frequency Range 60 Hz to 20 kHzDimensions (W H D) 270 mm 1 085.5 mm 310 mmMass 8.8 kg eachCenter speaker (SP-THC9C) Speaker unit Woof
12、er 10.0 cm 2Tweeter 4 cmBass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance 4 Frequency Range 65 Hz to 20 kHzDimensions (W H D) 380 mm 141 mm 168 mmMass 3.4 kgSurround speakers (SP-THC9S) Speaker unit 8.0 cmBass-reflexPower Handling Capacity 140 WImpedance 4 Frequency Range 80 H
13、z to 20 kHzDimensions (W H D) 111.5 mm 148 mm 106.5 mmMass 0.44 kg each1-4 (No.MB427)SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madet
14、o the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterati
15、ons of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safet
16、y-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are
17、 identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replac
18、ement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention
19、 of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check
20、 on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly
21、 into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate chec
22、k methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between anexposed metal part and a known good earth ground.Measure the AC voltage acros
23、s the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any
24、mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcTHC9ServiceManual 电路 原理图