Jvc-UXV-10-GN-Service-Manual电路原理图.pdf
《Jvc-UXV-10-GN-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXV-10-GN-Service-Manual电路原理图.pdf(70页珍藏版)》请在收音机爱好者资料库上搜索。
1、1-1UX-V10GNSERVICE MANUALMICRO COMPONENT SYSTEMNo.20886Dec. 2000COPYRIGHT 2000 VICTOR COMPANY OF JAPAN, LTD.UX-V10GNUX-V10GNContentsSafety precautionsImportant for laser productsDisassembly methodMain adjustmentFlow of functional operation until TOC readMaintenance of laser pickupReplacement of lase
2、r pickup Description of major ICs1-21-41-51-151-191-201-201-21This service manual is printed on 100% recycled paper.AUTO REVERSEAUTO TAPE SELECTORDOWN UPMULTI CONTROLTAPE FM/AM CDSTANDBYPHONESAUXRECREV.MODEAHBPROTIMERCLOCKVERTICAL DISCLOADING MECHANISMCOMPACTDIGITAL AUDIOVOLUMECDOPEN/CLOSEREMOTE CON
3、TROL RM-SUXV10ECANCELTREBLEFM/AMFM MODEDISPLAYSLEEPAUX TAPE CDCDBASSAHB PRODOWNRANDOMUPAUTOPRESETREPEATSETPROGRAMVOLUMETAPEMICRO COMPONENT SYSTEM UX-V10Area SuffixUFUNChinaIndonesia1-2UX-V10GNSafety Precautions1. This design of this product contains special hardware and many circuits and components
4、specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. Services should be performed by qualified personnel only.2. Alterati
5、ons of the design or circuitry of the product should not be made. Any design alterations of the product should not be made. Any design alterations or additions will void the manufacturers warranty and will further relieve the manufacture of responsibility for personal injury or property damage resul
6、ting therefrom.3. Many electrical and mechanical parts in the products have special safety-related characteristics. These characteristics are often not evident from visual inspection nor can the protection afforded by them necessarily be obtained by using replacement components rated for higher volt
7、age, wattage, etc. Replacement parts which have these special safety characteristics are identified in the Parts List of Service Manual. Electrical components having such features are identified by shading on the schematics and by ( ) on the Parts List in the Service Manual. The use of a substitute
8、replacement which does not have the same safety characteristics as the recommended replacement parts shown in the Parts List of Service Manual may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the like to be separate
9、d from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after re-assembling.5.
10、 Leakage currnet check (Electrical shock hazard testing)After re-assembling the product, always perform an isolation check on the exposed metal parts of the product (antenna terminals, knobs, metal cabinet, screw heads, headphone jack, control shafts, etc.) to be sure the product is safe to operate
11、without danger of electrical shock.Do not use a line isolation transformer during this check.Plug the AC line cord directly into the AC outlet. Using a “Leakage Current Tester“, measure the leakage current from each exposed metal parts of the cabinet , particularly any exposed metal part having a re
12、turn path to the chassis, to a known good earth ground. Any leakage current must not exceed 0.5mA AC (r.m.s.)Alternate check methodPlug the AC line cord directly into the AC outlet. Use an AC voltmeter having, 1,000 ohms per volt or more sensitivity in the following manner. Connect a 1,500 10W resis
13、tor paralleled by a 0.15 F AC-type capacitor between an exposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the AC voltmeter. Move the resistor connection to eachexposed metal part, particularly any exposed metal part having a return path to the chassis,
14、and meausre the AC voltage across the resistor. Now, reverse the plug in the AC outlet and repeat each measurement. voltage measured Any must not exceed 0.75 V AC (r.m.s.). This corresponds to 0.5 mA AC (r.m.s.). Warning1. This equipment has been designed and manufactured to meet international safet
15、y standards.2. It is the legal responsibility of the repairer to ensure that these safety standards are maintained.3. Repairs must be made in accordance with the relevant safety standards.4. It is essential that safety critical components are replaced by approved parts.5. If mains voltage selector i
16、s provided, check setting for local voltage.Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE!CAUTIONBurrs formed during molding may be left over on some parts of the chassis. Therefore, pay attention to such bu
17、rrs in the case of preforming repair of this system.1-3UX-V10GNWarning1. Service should be performed by qualified personnel only.2. This equipment has been designed and manufactured to meet international safety standards.3. It is the legal responsibility of the repairer to ensure that these safety s
18、tandards are maintained.4. Repairs must be made in accordance with the relevant safety standards.5. It is essential that safety critical components are replaced by approved parts.6. If mains voltage selector is provided, check setting for local voltage.Safety precautions1. This design of this produc
19、t contains special hardware and many circuits and components specially for safety purposes. For continued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Replacement parts must be identical to those used in the original circuits. 2. Any
20、unauthorised design alterations or additions will void the manufacturers guarantee ; furthermore the manufacturer cannot accept responsibility for personal injury or property damage resulting therefrom.3. Essential safety critical components are identified by ( ) on the Parts List and by shading on
21、the schematics, and must never be replaced by parts other than those listed in the manual. Please note however that many electrical and mechanical parts in the product have special safety related characteristics. These characteristics are often not evident from visual inspection. Parts other than sp
22、ecified by the manufacturer may not have the same safety characteristics as the recommended replacement parts shown in the Parts List of the Service Manual and may create shock, fire, or other hazards.4. The leads in the products are routed and dressed with ties, clamps, tubings, barriers and the li
23、ke to be separated from live parts, high temperature parts, moving parts and/or sharp edges for the prevention of electric shock and fire hazard. When service is required, the original lead routing and dress should be observed, and it should be confirmed that they have been returned to normal, after
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcUXV10GNServiceManual 电路 原理图