Jvc-RX-6042-S-Service-Manual电路原理图.pdf
《Jvc-RX-6042-S-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-RX-6042-S-Service-Manual电路原理图.pdf(48页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2004 Victor Company of Japan, LimitedNo.MB2672004/6AUDIO/VIDEO CONTROL RECEIVERMB26720046RX-6042STABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32
2、 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-43 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
3、54 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-135 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . 1-14TA/NEWS/INFODISPLAY MODEArea suffixA - Ausitralia1-2 (No.MB267)SPECIFICATION*1: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz)Designs and specifications are subject to change without notice.AmplifierOutput PowerAt S
5、tereo operation Front channels 100 W per channel, min. RMS, driven into 8 , 40 Hz to 20 kHz with no morethan 0.8% total harmonic distortion.At Surround operation Front channels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than0.8% total harmonic distortion.Center channel 100 W,
6、 min. RMS, driven into 8 , at 1 kHz with no more than 0.8% totalharmonic distortion.Surround chan-nels100 W per channel, min. RMS, driven into 8 , at 1 kHz with no more than0.8% total harmonic distortion.AudioAudio Input Sensitivity/Impedance (1 kHz)CD, TAPE/CDR, VCR, TV SOUND, DVD:220 mV/47 kAudio
7、Input (DIGITAL IN)*1 Coaxial DIGITAL 1 (DVD)Optical DIGITAL 2 (CD), DIGITAL 3 (TV):-21 dBm to -15 dBm (660 nm 30 nm)Recording Output Level TAPE/CDR, VCR:220 mVSignal-to-Noise Ratio (66 IHF/78 IHF)CD, TAPE/CDR, VCR, TV SOUND, DVD:87 dB/62 dBFrequency Response (8 ) CD, TAPE/CDR, VCR, TV SOUND, DVD:20
8、Hz to 50 kHz (+1 dB, -3 dB)Bass Boost +3 dB 1 dB at 100 HzEqualization (5 bands) 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz:8 dB (in 2 dB steps)VideoVideo Input Sensitivity/Impedance Composite video:DVD, VCR 1 V(p-p)/75 S-video:DVD, VCR (Y: luminance):1 V(p-p)/75 (C: chrominance, burst):0.286 V(p-p)/75 Com
9、ponentDVD, VCR (Y: luminance):1 V(p-p)/75 (PB, PR):0.7 V(p-p)/75 Video Output Level Composite video:VCR, MONITOROUT1 V(p-p)/75 S-video:VCR, MONITOR OUT (Y: luminance):1 V(p-p)/75 :0.286 V(p-p)/75 (C: chrominance, burst)ComponentMONITOR OUT (Y: luminance):1 V(p-p)/75 (PB, PR)0.7 V(p-p)/75 Synchroniza
10、tion NegativeSignal-to-Noise Ratio 45 dB(No.MB267)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safetypurposes. For continued protection, no changes should bemade to the original design unless autho
11、rized in writing bythe manufacturer. Replacement parts must be identical tothose used in the original circuits. Services should beperformed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made
12、. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. Thesechar
13、acteristics are often not evident from visual inspectionnor can the protection afforded by them necessarily beobtained by using replacement components rated forhigher voltage, wattage, etc. Replacement parts whichhave these special safety characteristics are identified inthe Parts List of Service Ma
14、nual. Electrical componentshaving such features are identified by shading on theschematics and by ( ) on the Parts List in the ServiceManual. The use of a substitute replacement which doesnot have the same safety characteristics as therecommended replacement parts shown in the Parts List ofService M
15、anual may create shock, fire, or other hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When servic
16、e is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, afterreassembling.(5) Leakage shock hazard testingAfter reassembling the product, always perform anisolation check on the exposed metal parts of the product(antenna
17、 terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“
18、, measure the leakage currentfrom each exposed metal parts of the cabinet,particularly any exposed metal part having a return pathto the chassis, to a known good earth ground. Anyleakage current must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outle
19、t. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between anexposed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor c
20、onnection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0
21、.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4)
22、 It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case ofpreformin
23、g repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor
24、 safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcRX6042SServiceManual 电路 原理图