1、SERVICE MANUALCOPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB1712004/3AUDIO/VIDEO CONTROL RECEIVERMB17120043RX-5042STABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32
2、 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-
3、64 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-135 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. . . . 1-14Area suffixJ - U.S.A.C - Canada1-2 (No.MB171)SPECIFICATIONDesigns and specifications are subject to change without notice.AmplifierOutput PowerAt Stereo operation Front channels 100 W per channel, min. RMS, driven into 8 , 40 Hz to 20 kHz withno more than 0.8% total harmonic distortion.A
5、t Surround operation Front channels 100 W per channel, min. RMS, driven into 8 , at 1 kHz with no morethan 0.8% total harmonic distortion.Center channel 100 W, min. RMS, driven into 8 , at 1 kHz with no more than 0.8%total harmonic distortion.Surround channels 100 W per channel, min. RMS, driven int
6、o 8 , at 1 kHz with no morethan 0.8% total harmonic distortion.AudioAudio Input Sensitivity/Impedance (1 kHz)CD, TAPE/CDR, VCR, TV SOUND, DVD:220 mV/47 kAudio Input (DIGITAL IN)* Coaxial DIGITAL 1 (DVD):0.5 V(p-p)/75 Optical DIGITAL 2 (CD):-21 dBm to -15 dBm (660 nm 30 nm)* Corresponding to Linear P
7、CM, Dolby Digital, and DTS Digital Surround (with sampling frequency-32 kHz, 44.1 kHz, 48 kHz)Recording Output Level TAPE/CDR, VCR:220 mVSignal-to-Noise Ratio(66 IHF/78 IHF) CD, TAPE/CDR, VCR, TV SOUND, DVD:87 dB/74 dBFrequency Response (8 ) CD, TAPE/CDR, VCR, TV SOUND, DVD:20 Hz to 50 kHz (+1 dB, -
8、3 dB)Bass Boost +3 dB 1 dB at 100 Hz (Only for RX-6040B/RX-6042S)Equalization (5 bands) 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHz (8 dB in 2 dB steps)VideoVideo Input Sensitivity/Impedance Composite video:DVD, VCR 1 V(p-p)/75 Video Output Level Composite video:VCR, MONITOR OUT 1 V(p-p)/75 Synchronization
9、NegativeSignal-to-Noise Ratio 45 dBFM tuner (IHF)Tuning Range 87.5 MHz to 108.0 MHzUsable Sensitivity Monaural:12.8 dBf (1.2 V/75 )50 dB Quieting Sensitivity Monaural:16.0 dBf (1.7 V/75 )Stereo:37.5 dBf (20.5 V/75 )Stereo Separation at OUT (REC) 35 dB at 1 kHzAM tunerTuning Range 530 kHz to 1 710 kH
10、zGeneralPower Requirements AC 120V , 60 HzPower Consumption 200 W/260 VA (at operation):2 W (in standby mode)Dimensions (W H D) 435 mm 146.5 mm 369.5 mm (17 3/16 in. 5 13/16 in. 14 5/8 in.)Mass 7.5 kg (16.6 lbs)(No.MB171)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product con
11、tains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should
12、 be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsi
13、bility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by
14、us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts Li
15、st in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamp
16、s, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been
17、 returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis
18、safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal pa
19、rt having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500
20、10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the cha
21、ssis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international
22、 safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage sel
23、ector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the
24、silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the