Jvc-UXG-33-Service-Manual电路原理图.pdf
《Jvc-UXG-33-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXG-33-Service-Manual电路原理图.pdf(55页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5362006/6MICRO COMPONENT SYSTEMMB53620066UX-G35US,UX-G35UB,UX-G33A,UX-G33US,UX-G33UB,UX-G33UW,UX-G30US,UX-G30UB,UX-G30UWLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUT
2、ION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DIS
3、ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . 1-215 TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-22CA-UXG35 SP-UXG35SP-UXG35CA-UXG33 SP-UXG33SP-UXG33CA-UXG30 SP-UXG30SP-UXG301-2 (No.MB536)SPECIFICATIONDesign and specifications are sub
5、ject to change without notice.Amplifier section Output Power 60 W (30 W + 30 W) at 6 (10% THD)Speakers/Impedance 6 - 16 Audio Input AUX 500 mV/50 k (at “AUX LVL 1“)250 mV/50 k (at “AUX LVL 2“)125 mV/50 k (at “AUX LVL 3“)Tuner section FM tuning range 531 kHz - 1 710 kHz (at 9 kHz intervals)AM tuning
6、range 530 kHz - 1 710 kHz (at 10 kHz intervals)CD player section Dynamic range 88 dBSignal-to-noise ratio 93 dBWow and flutter ImmeasurableCassette deck section Frequency response Normal (type I): 50 Hz - 14 000 HzWow and flutter 0.15% (WRMS)Speakers Speaker units 10 cm cone 1 + 1.5 cm dome 1Impedan
7、ce 6 Dimensions (approx.) 140 mm 231 mm 195 mm (W/H/D)Mass (approx.) 1.7 kg eachGeneral Power requirement Hong Kong AC 220 V , 50 HzAustralia AC 240 V , 50 Hzother AC 110 V/AC 127 V/AC 220 V/AC 230 V - 240 V , 50 Hz/60 Hz(adjustable with the voltage selector)Power consumption Hong Kong 50 W (at oper
8、ation)9.5 W (on standby/display on)1.1 W (on standby/display off)Australia 50 W (at operation)10 W (on standby/display on)1.3 W (on standby/display off)other 60 W (at operation)14.8 W (on standby/display on)3.8 W (on standby/display off)Dimensions (approx.) 165 mm 231 mm 328 mm (W/H/D)Mass (approx.)
9、 4.5 kg(No.MB536)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufact
10、urer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or a
11、dditions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not e
12、vident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical comp
13、onents having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create s
14、hock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the
15、original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, k
16、nobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the
17、 leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use an
18、AC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connecti
19、on to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC
20、 (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is
21、essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming rep
22、air of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safe
23、ty. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TY
24、PE1-4 (No.MB536)1.5 Safety Precautions (U.K only)(1) This design of this product contains special hardware and many circuits and components specially for safety purposes. For con-tinued protection, no changes should be made to the original design unless authorized in writing by the manufacturer. Rep
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcUXG33ServiceManual 电路 原理图