1、SERVICE MANUALCOPYRIGHT 2010 Victor Company of Japan, LimitedNo.MB7432010/6MICRO COMPONENT SYSTEMMB74320106SERVICE MANUALUX-F3BA, UX-F3BB, UX-F3BC, UX-F3BE, UX-F3BEN, UX-F3BEV, UX-F3BJ, UX-F3BUJ, UX-F3HB, UX-F3HE, UX-F3HEN, UX-F3HEVCOPYRIGHT 2010 Victor Company of Japan, LimitedLead free solder used
2、 in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-115 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-11SP-UXF3BSP-UXF3BCA-UXF3BSP-UXF3HSP-UXF3HCA
5、-UXF3Hexcept UX-F3BJ/CexceptUX-F3BJ/C1-2 (No.MB743)SPECIFICATIONDesign and specifications are subject to change without notice.Main unit (CA-UXF3B/CA-UXF3H) For B.E.EN.EV For J.CGeneralPower source AC 230 V , 50 Hz AC 120 V , 60 HzPower consumption (at operation) 40 WPower consumption (on standby) 1
6、.00 W or lessDimensions (approx.) (W x H x D) 236 mm 123 mm 285 mm (including projecting parts)236 mm 123 mm 285 mm (9-5/16“4-7/8“11-1/4“)(including projecting parts)Mass (approx.) 2.0 kg 2.0 kg(4.5 lbs)AmplifierOutput Power 60 W (30 W + 30 W) at 6 (10% THD)Audio Input AUDIO IN: Stereo mini ( 3.5 mm
7、)Speaker impedance 6 - 16 TunerFM frequency 87.50 MHz - 108.00 MHzUSB (Only Europe)USB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible system FAT16, FAT32Output power DC 5 V 500 mAiPodOutput power DC 5 V 500 mAVideo out CompositeSpeaker(SP-UXF3B/SP-UXF3
8、H)Speaker type Bass-reflex typeTweeter 4 cm 4 cm(1-5/8“)Woofer 12 cm 12 cm(4-3/4“)Impedance 6 Dimensions (approx.) (W x H x D) 141 mm 250 mm 181 mm (including projecting parts)141 mm 250 mm 181 mm (5-9/16“9-7/8“7-3/16“)(including projecting parts)Mass (approx.) 1.8 kg each 1.7 kg (3.8 lbs) each(No.M
9、B743)1-3Design and specifications are subject to change without notice.UX-F3BA/UX-F3BUJGeneralPower source For Australian model AC 240 V , 50 HzFor another model AC 110 V - 127 V / 220 V - 240 V adjustable with voltage selector, 50/60 HzPower consumption (at operation) 40 WPower consumption (on stan
10、dby) 1.00 W or lessDimensions (approx.) (W H D) 236 mm 123 mm 285 mm (including projecting parts)Mass (approx.) 2.0 kgAmplifierOutput Power 60 W (30 W + 30 W) at 6 (10% THD)Audio Input AUDIO IN: Stereo mini ( 3.5 mm)Speaker impedance 6 - 16 TunerFM frequency 87.50 MHz - 108.00 MHzUSBUSB specificatio
11、n Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible system FAT16, FAT32Output power DC 5 V 500 mAiPodOutput power DC 5 V 500 mAVideo out CompositeSpeaker(SP-UXF3B)Speaker type Bass-reflex typeTweeter 4 cmWoofer 12 cmImpedance 6 Dimensions (approx.) (W H D) 141 mm 250 m
12、m 181 mm (including projecting parts)Mass (approx.) 1.8 kg each1-4 (No.MB743)SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the or
13、iginal design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of t
14、he product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-relate
15、d characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identif
16、ied in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement pa
17、rts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of elec
18、tric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the
19、exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into th
20、e AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check method
21、Plug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the
22、resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustno
23、t exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made i
24、n accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, p