1、SERVICE MANUALCOPYRIGHT 2003 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB1122003/12DVD DIGITAL CINEMA SYSTEMMB112200312TH-M65TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SP
2、ECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74
3、ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-355 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、 . . 1-40Area suffixUS - SingaporeUW - Brazil,Mexico,PeruUJ - U.S.MilitaryUG - Turkey,South Africa,EgyptXV-THM65SP-PWM65 SP-THM65C SP-THM65F SP-THM65F SP-THM65F SP-THM65F1-2 (No.MB112)SPECIFICATIONDesigns & specifications are subject to change without notice.Center unit (XV-THM65)Audio Audio input s
5、ensitivity/Impedance (at 1 kHz), Total Harmonic Distortion 0.02 %NOTE : This value is measured at System cord CONNECTOR for reference.Analog input AUDIO IN (VCR) 290 mV/47 KMIC 4.3 mV/600 Digital input* DIGITAL IN (DBS) -21 dBm to -15 dBm(OPTICAL) (660 nm E30 nm)* Corresponding to Linear PCM, Dolby
6、Digital, and DTS Digital Surround (with sampling frequency - 32 kHz, 44.1 kHz, 48 kHz)Digital output DIGITAL OUT -21 dBm to -15 dBm(OPTICAL) (660 nm E30 nm)Video Color System NTSC/PAL selectableHorizontal Resolution 500 linesSignal-to-Noise Ratio 64 dBVideo output level Composite 1.0 V(p-p)/75 S-vid
7、eo-Y 1.0 V(p-p)/75 S-video-C 0.286 V(p-p)/75 Component-Y 1.0 V(p-p)/75 Component-PB/PR 0.7 V(p-p)/75 Video input sensitivity/Impedance (VCR IN)Composite 1.0 V(p-p)/75 S-video-Y 1.0 V(p-p)/75 S-video-C 0.286 V(p-p)/75 Tuner Tuning Range FM 87.50 MHz to 108.00 MHzAM 531 kHz to 1 602 kHz (at 9 kHz inte
8、rvals)530 kHz to 1 600 kHz (at 10 kHz intervals)General Power Requirements AC 110 - 230 V , 50 Hz/60 HzPower Consumption 20 W (at operation) 1.6 W (in standby mode)Dimensions (W H D) 400 mm 85 mm 386 mmMass 4.6 kgSubwoofer (SP-PWM65)Amplifier Front/Center/Surround 80 W per channel, RMS at 6 at 1 kHz
9、, with 10 % total harmonic distortion.Subwoofer 120 W, RMS at 4 at 100 Hz, with 10 % total harmonic distortion.Speaker Speaker unit 20 cm Bass-reflex, Magnetically ShieldedFrequency Range 25 Hz to 200 HzGeneral Power Requirements AC 110 V/127 V/220 - 230 V selectable with the voltage selector, 50 Hz
10、/60 HzPower Consumption 150 W (at operation) 0 W (in standby mode)Dimensions (W H D) 235 mm 355 mm 492 mmMass 13.0 kgSatellite Speakers (SP-THM65F)Speakers 5.5 cm 2 Bass-reflex, Magnetically ShieldedPower Handling Capacity 80 WImpedance 6 Frequency Range 90 Hz to 20 kHzDimensions (W H D) 250 mm 1 10
11、3 mm 250 mmMass 3.77 kgCenter Speaker (SP-THM65C)Speakers 5.5 cm 2 Bass-reflex, Magnetically ShieldedPower Handling Capacity 80 WImpedance 6 Frequency Range 90 Hz to 20 kHzDimensions (W H D) 258 mm 75 mm 81 mmMass 0.95 kg(No.MB112)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this p
12、roduct contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Servi
13、ces should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture o
14、f responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be ob
15、tained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onth
16、e Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with
17、ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they
18、 have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the
19、productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any expose
20、d metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connec
21、t a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath
22、to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet int
23、ernational safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains v
24、oltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appeari