1、SERVICE MANUALCOPYRIGHT 2004 VICTOR COMPANY OF JAPAN, LIMITEDNo.MB2072004/4COMPACT COMPONENT SYSTEMMB20720043MX-SK1TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECI
2、FIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64 ADJ
3、USTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-305 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4、. 1-34COMPACTDIGITAL AUDIOCOMPACTDIGITAL VIDEOPHONESACTIVEBASS EX.EJECTEJECTDISCSELECTSELECTM X - S K 3COMPACTDIGITAL VIDEOVOLUMESTANDBY/ONFM MODEAUXSLEEPFM/AMVIDEO INTROPREV. NEXTHIGHLIGHTON SCREENSETENTERRETURNPBC STILL KEY CONTROLDISC 1 DISC 2 DISC 3 DISCREPEAT PROGRAM RANDOM PROGRAMCANCELSOUNDTU
5、RBOSOUNDMODEACTIVEBASS EX.TAPE-AKARAOKE MPXECHO FADEMUTINGTAPE-BVOLUMEREMOTE CONTROLSTART/STOPRECCA-MXSK1SP-MXSK1 SP-MXSK1EE - Russian FederationArea suffix1-2 (No.MB207)SPECIFICATIONDesign & specifications are subject to change without notice.Amplifier sectionOutput Power MAIN SPEAKERS 64 W per cha
6、nnel min. RMS both channels driven into6 at 1 kHz with no more than 0.9% total harmonicdistortion.Audio input sensitivity/Impedance(Measured at 1 kHz with tape record-ing signal 300 mV)AUX 400 mV/50 kMIC 3 mV/10 kTunerFM tuning range 87.50 MHz to 108.00 MHzAM tuning range At 9 kHz intervals 531 kHz
7、to 1 710 kHzAt 10 kHz intervals 530 kHz to 1 710 kHzCD playerCD capacity 3 CDsDynamic range 85 dBSignal-to-noise ratio 90 dBWow and flutter ImmeasurableCassette deckFrequency response Normal (type I) 50 Hz to 14 000 HzWow and flutter 0.15% (WRMS)GeneralPower requirement AC 110 V / AC 127 V / AC 220
8、V / AC 230 V to AC 240 V (adjustable with the voltage selector)Power consumption 50 Hz / 60 Hz100 W (at operation)20 W (on standby)Dimensions (approx.) 270 mm x 306 mm x 433.5 mm (W/H/D)Mass (approx.) 9.2 kgSpeaker SpecificationsType 3-Way 3 Speaker Bass-Reflex (Magnetically-Shielded Type)Speakers M
9、ain woofer 15cm cone x 1Mid Range 5.0cm cone x 1Tweeter 2.0cm dome x 1Power Handling Capacity 80 WImpedance 6 Frequency Range 42 Hz to 30 000HzSound Pressure Level 84 dB/W.mDimensions (W x H xD) 215mm x 306 mm x 243 mmMass 3.4 kg(No.MB207)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design o
10、f this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuit
11、s. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanuf
12、acture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessari
13、ly be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by
14、( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dress
15、ed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedt
16、hat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be s
17、ure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly an
18、y exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner
19、. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a ret
20、urnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured to
21、meet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If
22、 mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts