Jvc-THC-6-Service-Manual电路原理图.pdf
《Jvc-THC-6-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-THC-6-Service-Manual电路原理图.pdf(81页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4282005/7DVD DIGITAL CINEMA SYSTEMMB42820057TH-C6Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-42 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-84 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-305 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-35Area suffixA - AustraliaUW - Brazil,Mexico,PeruUY - ArgentinaUJ - U.S.MilitaryUG - Turkey,South Africa,Egypt(XV-THC6)(SP-PWC6)(SP-THC6F)(SP-THC6F) (SP-THC6C) (SP-THC6S)1-2 (No.MB428)SPECIFICATIONCenter unit
5、 (XV-THC9/XV-THC6/XV-THC3)*1: This value is measured at System cord CONNECTOR for reference.*2: Corresponding to Linear PCM, Dolby Digital, and DTS Digital Surround (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz)Subwoofer (SP-PWC6/SP-PWC3)Audio section Total Harmonic Distortion *1 0.02%Digital i
6、nput*2 DIGITAL IN (DBS)(OPTICAL)-21 dBm to -15 dBm(660 nm 30 nm)Video section Video System PAL/NTSCHorizontal Resolution 500 linesSignal-to-Noise Ratio 64 dBVideo output level Composite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Com
7、ponent-Y: 1.0 V(p-p)/75 Component-PB/PR: 0.7 V(p-p)/75 Video input sensitivity/Impedance (VCR IN) Composite: 1.0 V(p-p)/75 S-video-Y: 1.0 V(p-p)/75 S-video-C: For PAL: 0.3 V(p-p)/75 S-video-C: For NTSC: 0.286 V(p-p)/75 Tuner section Tuning Range FM 87.5 MHz to 108.0 MHzAM (Except for Middle East) 53
8、1 kHz to 1 710 kHz (at 9 kHz channel spacing)530 kHz to 1 710 kHz (at 10 kHz channel spacing)AM (For Middle East) 531 kHz to 1 602 kHz (at 9 kHz channel spacing)530 kHz to 1 600 kHz (at 10 kHz channel spacing)General Power Requirements AC 110-240 V , 50/60 HzPower Consumption 19 W (at operation)1.9
9、W (in standby mode)Dimensions (W H D) 400 mm 85 mm 399 mmMass 4.2 kgAmplifier section Front 140W per channel, RMS at 4 at 1 kHz, with 10% total harmonic dis-tortion.Center/Surround 130W per channel, RMS at 4 at 1 kHz, with 10% total harmonic dis-tortion.Subwoofer 140 W, RMS at 4 at 100 Hz, with 10%
10、total harmonic distortion.Speaker section Speaker unit 16 cm Bass-reflexPower Handling Capacity 140 WImpedance 4 Frequency Range 30 Hz to 200 HzGeneral Power Requirements Except for Australia AC 110 V/ AC 127 V/AC 220-240 V , 50/60 HzFor Australia only AC 240 V , 50 HzPower Consumption 135 W (at ope
11、ration)0 W (in standby mode)Dimensions (W H D) 169 mm 411 mm 459 mmMass 11.3 kg(No.MB428)1-3Satellite Speakers (SP-XTHC6)Designs & specifications are subject to change without notice.Front speakers (SP-THC6F) Speaker unit 5.5 cm 2, 1.5 cm, Bass-reflex, Magnetically ShieldedPower Handling Capacity 14
12、0 WImpedance 4 Frequency Range 90 Hz to 20 kHzDimensions (W H D) 250 mm 1 104 mm 250 mmMass 2.6 kg eachCenter speaker (SP-THC6C) Speaker unit 5.5 cm 2, 1.5 cm, Bass-reflex, Magnetically ShieldedPower Handling Capacity 140 WImpedance 4 Frequency Range 90 Hz to 20 kHzDimensions (W H D) 320 mm 75 mm 92
13、 mmMass 0.9 kgSurround speakers (SP-THC6S) Speaker unit 5.5 cm 2, 1.5 cm, Bass-reflexPower Handling Capacity 140 WImpedance 4 Frequency Range 90 Hz to 20 kHzDimensions (W H D) 250 mm 1 142 mm 250 mmMass 2.6 kg each1-4 (No.MB428)SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product
14、 contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services sh
15、ould be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of resp
16、onsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained
17、 by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Part
18、s List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,c
19、lamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have
20、been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the produc
21、tis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed meta
22、l part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,
23、500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the
24、 chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet internati
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcTHC6ServiceManual 电路 原理图