Kenwood-KDCMP-248-U-Service-Manual电路原理图.pdf
《Kenwood-KDCMP-248-U-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Kenwood-KDCMP-248-U-Service-Manual电路原理图.pdf(33页珍藏版)》请在收音机爱好者资料库上搜索。
1、This product uses Lead Free solder.This product complies with the RoHS directive for the European market.SERVICE MANUALKDC-208U/248U/4051UGM/4051URMKDC-MP148U/MP248U/U3049KDC-U349A/U349G/U349R/U349SKDC-U4049CD RECEIVER 2010-12 PRINTED IN JA PANB53-0833-00 (N) 217TDF SPARE-PANELMAIN UNIT NAME TDF PAR
2、TS No. TDF NAMEKDC-208U Y33-3390-11 TDF-120DKDC-248U Y33-3380-10 TDF-128DKDC-4051UGM Y33-3400-26 TDF-4051UGMKDC-4051URMKDC-MP148U Y33-3390-10 TDF-MP11DUKDC-MP248U Y33-3380-11 TDF-MP12DUKDC-U3049 Y33-3400-20 TDF-U3049KDC-U349A Y33-3400-24 TDF-U349AKDC-U349G Y33-3400-23 TDF-U349GKDC-U349R Y33-3400-21
3、TDF-U349RKDC-U349S Y33-3400-22 TDF-U349SKDC-MP248U : Panel assy (GE20277-017A)KDC-248U : Panel assy (GE20280-020A)KDC-U349A/G/R : Panel assy (GE20277-019A)KDC-U349S : Panel assy (GE20277-006A)Y33-3400-25 TDF-4051URMKDC-U4049 Y33-3403-01 TDF-U4049KDC-U4049 : Panel assy (GE20280-019A)After replacing E
4、2PROM (IC771 on X34), tuner setting adjustment is needed.The adjustment is that to perform the “TUNER Setting Adjustment Mode” (Page 5) in the “Tuner Test Mode Specification” of “Production Test Mode”.Tuner setting adjustment after replacing E2PROMMounting sleeve assy(GE34134-001A)Hook(GE40510-001A)
5、 x2* Car cable(E30-xxxx-xx)* Screw set(N99-1757-15)* Carrying case(W01-1710-05)* Car cable(E30-6937-05)* Tap screw (2x8)(N80-2008-43)* Hard case assy(A02-2757-13)* Remote control unit (RC-405)(A70-2104-05)Trim plate(GE20274-001A)KDC-4051UxM : Panel assy (GE20280-012A)KDC-MP148U : Panel assy (GE20280
6、-002A)KDC-U349KDC-MP248UKDC-MP148UKDC-248UKDC-U4049* Depends on the model. Refer to the parts list.KDC-4051UM2KDC-208U/248U/4051UGM/4051URM/MP148U/MP248UKDC-U3049/U349A/U349G/U349R/U349S/U4049BLOCK DIAGRAM1BU DETPHONERESET959BU DET12MUTER902,90312211111R631,632D8912FL+BPS1-1 / PS1-2 / PS1-3ACC5V / B
7、U-DETPS2-1 / PS2-2PHONEPS1-1 / PS1-2 / PS1-3PS2-1 / PS2-2 P-ANTP-CONSP-OUTPHONEACCBU5SW3.3VSW3.3VPON-FL18ACC5VPANEL3.3VCD1.5V CD3.3V22FL+B322FL+BE-VOLIC161A9VSYSTEM u-COM & USB HOSTQ321,341PHONEQ970BU DETQ971SW 3.3VQ951,952IC501AUDIOCDBU5VSW5(REMO DRV)RESET ICIC702ILLUMI+BCONNECTORRESET SWREMOFLIC70
8、1IC301IC602CN901ILLUMI+BEN601 FL601J321MUTEQ780IC1Q701VDD3.3Vto GNDS701CN601A9VANTE2PROMBU3.3VF-AUXJ602PANEL DETIC901CN701SW3.3VIC771TUNERROTARYENCODERKEYILLUMI(FL FILAMENT)RESISTORKEYMATRIXLOADRESISTORMOTORDRIVERICSUPPLYPOWERDC-CN etcMUTERCAAMPPOWERRCA-OUTDETSURGE-DC-CNBU5VSERVO IC(OASIS)IC540CD 3.
9、3VCD 1.5VIC530-532BUBU3.3VATOMIC(OE REMOTE)EXT REMOMECHACDCD3.3Vto MECHAJ1BU3.3Vto DCCONNECTORPANEL3.3VCDBU3.3VBU5VLOADSW3.3VIC931BU3.3VSW 3.3V BU5VPANEL SW3.3Q602BU3.3VBU5VUSB5VCPi-PodIC80SW3.3VSWHI-SIDEUSB5V(DC/DC)IC981IC961USB5VUSB CNCN603ELECTRIC UNIT (X34- )SWITCH UNIT (X16- )3KDC-208U/248U/405
10、1UGM/4051URM/MP148U/MP248UKDC-U3049/U349A/U349G/U349R/U349S/U40491. PanelACCENTSEARCHRETURN VOL2. How to enter each Test ModeTest Mode name OperationProduction Test Mode Press and hold 1 key and 3 key and reset.Service Test ModeIn the STANDBY source, while pressing and holding 2 key, press 6 key for
11、 7 seconds.(Starting to press 2 key and 6 key at the same time can not be entered into the mode)DC Error Information Mode Press and hold 3 key and 6 key and reset. Transition to Test Mode shall be available during DC Error detection.3. How to release each Test Mode Reset Momentary voltage drop ACC O
12、FF POWER OFF Panel Detach4. Production Test Mode Default status immediately after the mode activationIt shall be same as normal RST start in other settings than the following.DetailsDifference in actionPeriod to prohibit TEL/LINE MUTE immediately after activation (normally 10 seconds)1 secondMecha I
13、nitialize Action ProhibitedWrite-in to E2PROM when detecting a DC error ProhibitedDemo Mode ON/OFF Setting Menu ProhibitedPower supply during ACC OFF (Back Up On) MUTE terminal turns OFF after 2 secondsBEEP sound Beep with short-pressing in any functionsVarious setting value Volume 30 (-10dB)BASS BO
14、OST/LOUD OFFEQ NATURALFader/Balance CenterDEMO Mode Setting OFFAUX Setting ON1NAVI MUTE Setting for Japan Detecting function valid (ATT)TEST MODE4KDC-208U/248U/4051UGM/4051URM/MP148U/MP248UKDC-U3049/U349A/U349G/U349R/U349S/U4049 Mode structureSome Test Modes change according to the current source.Th
15、e following table shows the current source in Set and the related test mode status.Model source Test modePOWER OFF -Standby STANDBY Test ModeTUNER TUNER Test ModeCD CD Test ModeUSB -AUX - Mode contentSyscon shall display the following information after entering this mode. The operation shown below s
16、hall be workable.Display content DetailsPRO TESTThe display is released when another operation is executed.The display will blink if sub clock is not functioning. STANDBY Test Mode Specifi cationOperation Display content Details1 (Toggle)Syscom version display SYS0 Syscom version (Refer to Syscom Ve
17、rsion Table)All lights ON All lights ON (Switch with other display)2 (Toggle)Serial No. display SN 00000000Serial No. display (8-digit) Display as it is in hexAll lights ON All lights ON (Switch with other display)3 (Toggle) All lights ON/OFF All lights ON/OFF with toggle4 (Toggle)Information displa
18、y iPod verifi cation IC mount sta-tus displayiPod :iPod :OKiPod :NGiPod :iPod verifi cation IC mount status displayBlank: VerifyingOK: Verifi cation IC mountedNG: Verifi cation IC not mounted: Non-iPod support modelAll lights ON All lights ON (Switch to other display)5 (Toggle) Preout switchSWPR E R
19、E ARSWPRE SUB WSwitch Preout with toggle6 FL display short checkAll lights ON All lights OFF odd terminal and even terminal of the largest grid ON alternatively every 125ms odd terminal ON even terminal ON (repeat continuously)SOURCE transitionMode release Return to Normal modeRETURN Mode release Re
20、turn to Normal mode Tuner Test Mode Specifi cationThe following display shall be indicated according to the TUNER status.Status Display content DetailsTUNER IC Normal Error TUN CON NGCommunication to TUNER IC not available (indicated unless the mode is in Clock Display Mode).TEST MODE5KDC-208U/248U/
21、4051UGM/4051URM/MP148U/MP248UKDC-U3049/U349A/U349G/U349R/U349S/U4049Status Display content DetailsAdjustment not imple-mented ERR A97.9AFor models that TUNER adjustment is necessary but not done (adjustment value: 0x00 or 0xFF), the following TUNER Test Mode functions are valid (“ERR” display is con
22、tinuing).Display “ERR” blinks with 250ms interval.RDS Specifi ed data re-ception RDS TESTTurn OFF P-CON forcibly if PS=RDS TEST is received.P-CON recovers with Power OFF/ON.OperationsOperation Display content DetailsACCENT TUNER IC display ATOM RDS Display TUNER IC versionBANDBAND switch operationFM
23、1 3A 9 7.9AExecute Band Switch as shown in the following table every time Band key is pressed in each type.SEARCHS meter voltage judgment displaySMTR xx:OKSMTR xx:NGSMTR xx:S meter value xx: Current S meter valueDetermination result OK: Within S meter voltage specNG: Out of S meter voltage spec : No
24、 LEVEL OFFSET adjustmentDISPShift to TUNER setting modeShift to TUNER setting mode after switching to 98.3MHzSG setting valuesFrequency: 98.3MHz, Modulation frequency: 1kHz, Modulation mode: MONO, Modulation: OFF, Deviation: 40kHz, ANT input level: 34dBVTUNER Setting Adjustment Mode1. Operation (Ope