Jvc-UXNB-7-DABEN-Service-Manual电路原理图.pdf
《Jvc-UXNB-7-DABEN-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXNB-7-DABEN-Service-Manual电路原理图.pdf(57页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5732006/9MICRO COMPONENT SYSTEMMB57320069UX-NB7DABB,UX-NB7DABE,UX-NB7DABENLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-75 TROUBLESHOOTING . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7CA-UXNB7DAB SP-UXNB7DABSP-UXNB7DAB1-2 (No.MB573)SPECIFICATIONSpecifications and appearance are subject to change without prior notice.Amplifier section OUTPUT POWER 10 W (5 W + 5
5、W) at 4 (10% THD)Speakers/Impedance 4 - 16 Audio Input LINE IN 500 mV/47 k (at “LINE IN LVL1“)250 mV/47 k (at “LINE IN LVL2“)125 mV/47 k (at “LINE IN LVL3“)Audio Output LINE OUT 1.0 Vrms (47 k) (at “LINE OUT LVL1“)2.0 Vrms (47 k) (at “LINE OUT LVL2“)Tuner section FM Tuning range 87.50 MHz - 108.00 M
6、HzAM (MW) Tuning range 522 kHz - 1 629 kHzDAB tuning range BAND III 174.928 MHz - 239.200 MHzL-BAND 1 452.960 MHz - 1 490.624 MHzCD player section Dynamic range 88 dBSignal-to-noise ratio 93 dBWow and flutter ImmeasurableSpeakers Speaker units 8 cm cone 1Impedance 4 Dimensions (approx.) 130 mm 171 m
7、m 136 mm (W/H/D)Mass (approx.) 0.75 kg eachGeneral Power requirements AC 230 V , 50 HzPower consumption 20.0 W (Power on), 2.5 W (Standby mode)2.0 W or less (Save mode)Mass 1.8 kgDimensions (W H D) 270 mm 68.5 mm 203 mm(No.MB573)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this pro
8、duct contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Service
9、s should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of
10、responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obta
11、ined by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe
12、Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ti
13、es,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they h
14、ave been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the pr
15、oductis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed
16、metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect
17、a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to
18、 the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet inter
19、national safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains vol
20、tage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing
21、 on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specifie
22、d by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB573)1.5 Safety Precautions (U.K only)(1) This design of this product contain