Jvc-MXKC-45-Service-Manual电路原理图.pdf
《Jvc-MXKC-45-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-MXKC-45-Service-Manual电路原理图.pdf(71页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2006 Victor Company of Japan, LimitedNo.MB5502006/7COMPACT COMPONENT SYSTEMMB55020067MX-KC45E,MX-KC45EN,MX-KC45A,MX-KC45UW,MX-KC45UY,MX-KC45UJLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-53 DISASSEMBLY . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-64 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-125 TROUB
4、LESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-13CA-MXKC45 SP-MXKC45SP-MXKC451-2 (No.MB550)SPECIFICATIONDesign and specifications are subject to change without notice.Amplifier Output Power (IEC 268-3) 15
5、5 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 10% total harmonic distortion(DIN-3) 125 W per channel, min. RMS, driven into 6 at 1kHz, with no more than 0.9% total harmonic distortionInput Sensitivity/Impedance (1 kHz)AUX INSpeaker terminals400 mV/50 k6 - 16 Phones 32 - 1 k17 m
6、W/ch output into 32 Cassette Deck Section Frequency Response : Type I (NORMAL) 63 Hz - 12 500 HzWow And Flutter 0.15% (WRMS)CD Player CD Capacity 3 CDsDynamic Range 85 dBSignal-To-Noise Ratio 85 dBWow And Flutter UnmeasurableTuner FM Tuner : Tuning Range 87.50 MHz - 108.00 MHz87.50 MHz - 108.00 MHz
7、(at AM9 kHz channel space)87.5 MHz - 108.0 MHz (at AM10 kHz channel space)AM Tuner : Tuning Range 522 kHz - 1710 kHz522 kHz - 1 629 kHz (for Europe)531 kHz - 1710 kHz (at AM9 kHz channel space)530 kHz - 1710 kHz (at AM10 kHz channel space)Unit Dimensions 270 mm 307 mm 492 mm (W/H/D)Mass Approx. 9.3
8、kgSpeaker Specifications(each unit)Type 3-way bass-reflex typeSpeaker Unit Woofer 16 cm cone 1Mid 5cm cone 1Tweeter 2cm dome 1Power Handling Capacity 160 WImpedance 6 Frequency Range 45 Hz - 22 000 HzSound pressure level 87 dB/WmDimensions 220 mm 324 mm 238 mm (W/H/D)Mass Approx. 3.6 kgPower Specifi
9、cations Power Requirements AC 240 V , 50 Hz (for Australia)AC 230 V , 50 Hz (for Europe)AC 110 V-127 V/220 V-240 V , adjustable with voltage selector, 50 Hz/60 Hz (for Asia)Power Consumption 165 W (power on mode)23 W (in Standby mode)1 W (in ECO mode)(No.MB550)1-3SECTION 1PRECAUTION1.1 Safety Precau
10、tions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used i
11、n the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will fu
12、rther relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection affo
13、rded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on
14、the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the product
15、s are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and i
16、t should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control
17、 shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cab
18、inet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityi
19、n the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed m
20、etal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been design
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JvcMXKC45ServiceManual 电路 原理图