1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4482005/9AUDIO/VIDEO CONTROL RECEIVERMB44820059RX-D402B, RX-D401SLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-195 TROUBLESHOOTING . . . . . . . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-19Area suffixJ - U.S.A.1-2 (No.MB448)SPECIFICATION*Corresponding to Linear PCM, Dolby Digital, and DTS (with sampling frequency -32 kHz, 44.1 kHz, 48 kHz).Designs and specifications are subjec
5、t to change without notice.Amplifier Output Power At stereo operation Front channels 110 W per channel, min. RMS, driven into 6 at 20 Hz to 20 kHz with no more than 0.8% total harmonic distortion.At surround operation Front channels 110 W per channel, min. RMS, driven into 6 at 1 kHz with no more th
6、an 0.8% total har-monic distortion.Center channel 110 W, min. RMS, driven into 6 at 1 kHz,with no more than 0.8% total harmonic distortion.Surround channels 110 W per channel, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har-monic distortion.Surround back channels 110 W per channel
7、, min. RMS, driven into 6 at 1 kHz, with no more than 0.8% total har-monic distortion.Audio Audio Input Sensitivity/ImpedanceDVR/DVD, VCR, DBS, TV 270 mV/47 kAudio Input(DIGITAL IN)*Coaxial DIGITAL IN 1(DVR/DVD): 0.5 V(p-p)/75 Optical DIGITAL IN 2(DBS), 3(VCR): -21 dBm to -15 dBm (660 nm 30 nm)USB U
8、SBAudio Output Level DVR, VCR 270 mVSignal-to-Noise Ratio (66 IHF/78 IHF) 80 dB/62 dBFrequency Response (6 ) 20 Hz to 20 kHz (1 dB)Bass Boost +4 dB 1 dB at 100 HzEqualization(at DSP operation)Center frequency 63 Hz, 250 Hz, 1 kHz, 4 kHz, 16 kHzControl range 8 dBVideo Video Input Sensitivity/Impedanc
9、eComposite video:DVR/DVD, VCR, DBS 1 V(p-p)/75 S-video:DVR/DVD, VCR, DBS Y (luminance): 1 V(p-p)/75 C (chrominance, burst):0.286 V(p-p)/75 Component:DVR/DVD, VCR (DBS) Y (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Video Output Level/ImpedanceComposite video: DVR, VCR, MONITOR OUT 1 V(p-p)/75 S-vi
10、deo: DVR, VCR, MONITOR OUT Y (luminance): 1 V(p-p)/75 C (chrominance, burst): 0.286 V(p-p)/75 Component: MONITOR OUT Y (luminance): 1 V(p-p)/75 PB, PR: 0.7 V(p-p)/75 Synchronization NegativeHDMI HDMI Input (Ver. 1.1) VCR (DBS), DVR/DVDHDMI Output (Ver. 1.0) MONITOR OUTFM tuner (IHF) Tuning Range 87.
11、5 MHz to 108.0 MHzUsable Sensitivity Monaural 12.8 dBf (1.2 V/75 )50 dB Quieting Sensitivity Monaural 16.0 dBf (1.7 V/75 )Stereo 37.5 dBf (20.5 V/75 )Stereo Separation at REC OUT 35 dB at 1 kHzAM tuner Tuning Range 530 kHz to 1 710 kHzGeneral Power Requirements AC 120 V , 60 HzPower Consumption 150
12、W/200 VA (at operation)0.9 W (in standby mode)Dimensions (W H D) 435 mm 91.5 mm 371 mm (17 3/16 inch-es 3 5/8 inches 14 5/8 inches)Mass 7.1 kg (15.7 lbs)(No.MB448)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components spe
13、cially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations
14、 of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting the
15、refrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, wa
16、tt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplaceme
17、nt which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive
18、 parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock
19、 hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notu
20、se a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good ear
21、th ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor betwee
22、n an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now,
23、reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of th
24、e repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 Caut