1、SERVICE MANUALCOPYRIGHT 2005 Victor Company of Japan, LimitedNo.MB4122005/6MICRO COMPONENT SYSTEMMB41220056UX-G1Lead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-145 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-17CA-UXG1 SP-UXG1 SP-UXG1 TIMER SETRANDOM SLEEPREPEATSTANDBY/ONTIMERON/OFFREMAINBEAT CUTDISPLAY/CLOCK SETMUTINGSOUND/BASSCDTAPE CDVOLUMETUNER/BANDFM MODEPROGRAMREMOTE CONTROLSTANDBY/ONOPENVOLUMEMICRO COMPONENT S
5、YSTEMCD SYNCHRO RECORDINGArea suffixUS - SingaporeUB - Hong KongUT - TaiwanUW - Brazil,Mexico,PeruUY - Argentina1-2 (No.MB412)SPECIFICATIONAmplifier Section-CA-UXG1Speaker Section-SP-UXG1Design and specifications are subject to change without notice.Output Power (IEC 268-3) 10 W (5 W + 5 W) at 4 (10
6、% THD)Speakers/Impedance 4 - 16 Tuner FM tuning range 87.50 MHz-108.00 MHzAM tuning range AM 9 kHz intervals: 531 kHz-1 710 kHzAM 10 kHz intervals: 530 kHz-1 710 kHzCD player Dynamic range 85 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableCassette deck Frequency response Normal (type I) 10
7、0 Hz-10 000 HzWow and flutter 0.35 % (WRMS)General Power requirement AC 110 V-127 V/220 V-240 V adjustable with the voltage selector 50 Hz/60 HzPower consumption 22 W (at operation)4.5 W (on standby)Dimensions (W/H/D) (approx.) 145 mm 209 mm 226 mmMass (approx.) 3.0 kgType Full range Bass-reflex typ
8、eSpeakers 10 cm cone 1Power handling capacity 5 WImpedance 4 Frequency range 100 Hz to 15 kHzDimensions (W/H/D) (approx.) 135 mm 209 mm 152 mmMass (approx.) 1.3 kg each(No.MB412)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and
9、 components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.
10、(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamag
11、e resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for hig
12、her voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a subs
13、titutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be sep
14、arated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5
15、) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrica
16、l shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a
17、 known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type c
18、apacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe
19、resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal respo
20、nsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standards.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localv
21、oltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the
22、 PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are criticalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Ex
23、cept the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W0.15 F AC TYPE1-4 (No.MB412)1.5 Preventing static electricityElectrostatic discharge (ESD), which occurs when static electricity stored in the body, fa
24、bric, etc. is discharged, can destroy the laserdiode in the traverse unit (optical pickup). Take care to prevent this when performing repairs.1.5.1 Grounding to prevent damage by static electricityStatic electricity in the work area can destroy the optical pickup (laser diode) in devices such as las