1、SERVICE MANUALCOPYRIGHT 2007 Victor Company of Japan, LimitedNo.MB6172007/7MICRO COMPONENT SYSTEMMB61720076SERVICE MANUALUX-EP100A, UX-EP100US, UX-EP100UB, UX-EP100UW, UX-EP100UP, UX-EP100UTCOPYRIGHT 2007 Victor Company of Japan, LimitedLead free solder used in the board (material : Sn-Ag-Cu, meltin
2、g point : 219 Centigrade)Lead free solder used in the board (material : Sn-Cu, melting point : 230 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC S
3、ERVICE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-63 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTME
4、NT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-185 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
5、8CA-UXEP100SP-UXEP100SP-UXEP1001-2 (No.MB617)SPECIFICATIONSpecifications and appearance are subject to change without prior notice.Amplifier section OUTPUT POWER 20 W (10 W + 10 W) at 6 (10% THD)Speakers/Impedance 6 - 16 Audio input LINE IN 500 mV/47 k (at “LINE IN LVL1”)250 mV/47 k (at “LINE IN LVL
6、2”)125 mV/47 k (at “LINE IN LVL3”)Audio output LINE OUT 1.0 Vrms (47 k) (at “LINE OUT LVL1”)2.0 Vrms (47 k) (at “LINE OUT LVL2”)Digital input USB MEMORYTuner section FM tuning range 87.50 MHz - 108.00 MHzAM tuning range 530 kHz - 1 710 kHz (in 10 kHz spacing)531 kHz - 1 710 kHz (in 9 kHz spacing)CD
7、player section Dynamic range 90 dBSignal-to-noise ratio 85 dBWow and flutter ImmeasurableUSB storage USB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible file system FAT16, FAT32Bus power supply Max. 500 mASpeakers Speaker units 8 cm cone x 1Impedance 6
8、Dimensions (approx.) 100 mm x 184 mm x 151 mm (W/H/D)Mass (approx.) 0.7 kg eachGeneral Power requirements AC 110 V - 240 V , 50/60 HzAC 220 V , 50 Hz (only Hong Kong)Power supply to USB mass storage class device 5 V/500 mAPower consumption 20 W (power on)2.5 W (standby mode)1.5 W or less (Save Mode)
9、Dimensions (W x H x D) 287 mm x 70 mm x 220 mmMass 1.7 kg(No.MB617)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original
10、design unless authorized in writing by themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the prod
11、uct shouldnot be made. Any design alterations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related chara
12、cteristics. These characteris-tics are often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in
13、the Parts List of Ser-vice Manual. Electrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts sho
14、wn inthe Parts List of Service Manual may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric sh
15、ock and firehazard. When service is required, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed
16、 metal parts of the product (an-tenna terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC ou
17、tlet. Using a“Leakage Current Tester“, measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug th
18、e AC line cord directly into the AC outlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resisto
19、r with the ACvoltmeter. Move the resistor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot excee
20、d 0.75 V AC (r.m.s.). This corresponds to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accor