Jvc-UXDAB-11-B-Service-Manual电路原理图.pdf
《Jvc-UXDAB-11-B-Service-Manual电路原理图.pdf》由会员分享,可在线阅读,更多相关《Jvc-UXDAB-11-B-Service-Manual电路原理图.pdf(53页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE MANUALCOPYRIGHT 2007 Victor Company of Japan, LimitedNo.MB6332007/8MICRO COMPONENT SYSTEMMB63320078SERVICE MANUALUX-DAB11B, UX-DAB11ENCOPYRIGHT 2007 Victor Company of Japan, LimitedLead free solder used in the board (material : Sn-Ag-Cu, melting point : 219 Centigrade)Lead free solder used i
2、n the board (material : Sn-Cu, melting point : 230 Centigrade)TABLE OF CONTENTS1 PRECAUTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-32 SPECIFIC SERVICE INSTRUCTIONS . . . . . . . . . . . . . .
3、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-73 DISASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-74 ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . .
4、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-195 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-20CA-UXDAB11 SP-UXDAB11SP-UXDAB111-2 (No.MB633)SP
5、ECIFICATIONSpecifications and appearance are subject to change without prior notice.Amplifier section OUTPUT POWER 40 W (20 W + 20 W) at 6 (10% THD)Speakers/Impedance 6 - 16 Audio input LINE IN 500 mV/47 k (at “IN_LVL1”)250 mV/47 k (at “IN_LVL2”)125 mV/47 k (at “IN_LVL3”)Audio output LINE OUT 1.0 Vr
6、ms (47 k) (at “OUT_LVL1”)2.0 Vrms (47 k) (at “OUT_LVL2”)Digital input USB MEMORYTuner section FM Tuning range 87.50 MHz - 108.00 MHzAM (MW) Tuning range 522 kHz - 1 629 kHzDAB tuning range BAND III 174.928 MHz - 239.200 MHzL-BAND 1 452.960 MHz - 1 490.624 MHzCD player section Dynamic range 88 dBSign
7、al-to-noise ratio 85 dBWow and flutter ImmeasurableUSB storage USB specification Compatible with USB 2.0 Full SpeedCompatible device Mass storage classCompatible file system FAT16, FAT32Bus power supply Max. 500 mASpeakers Speaker units Tweeter 1.5 cm dome x 1Woofer 10 cm cone x 1Impedance 6 Dimensi
8、ons (approx.) 145 mm x 251 mm x 175 mm (W x H x D)Mass (approx.) 1.7 kg eachGeneral Power requirements AC 230 V , 50 HzPower supply to USB mass storage class device 5 V/500 mAPower consumption 22 W (Power on)2.3 W (On standby)1.0 W or less (Save Mode)Dimensions (approx.) 175 mm x 251 mm x 247 mm (W
9、x H x D)Mass 2.6 kg(No.MB633)1-3SECTION 1PRECAUTION1.1 Safety Precautions(1) This design of this product contains special hardware andmany circuits and components specially for safety purpos-es. For continued protection, no changes should be madeto the original design unless authorized in writing by
10、 themanufacturer. Replacement parts must be identical tothose used in the original circuits. Services should be per-formed by qualified personnel only.(2) Alterations of the design or circuitry of the product shouldnot be made. Any design alterations of the product shouldnot be made. Any design alte
11、rations or additions will voidthe manufacturers warranty and will further relieve themanufacture of responsibility for personal injury or propertydamage resulting therefrom.(3) Many electrical and mechanical parts in the products havespecial safety-related characteristics. These characteris-tics are
12、 often not evident from visual inspection nor can theprotection afforded by them necessarily be obtained by us-ing replacement components rated for higher voltage, watt-age, etc. Replacement parts which have these specialsafety characteristics are identified in the Parts List of Ser-vice Manual. Ele
13、ctrical components having such featuresare identified by shading on the schematics and by ( ) onthe Parts List in the Service Manual. The use of a substitutereplacement which does not have the same safety charac-teristics as the recommended replacement parts shown inthe Parts List of Service Manual
14、may create shock, fire, orother hazards.(4) The leads in the products are routed and dressed with ties,clamps, tubings, barriers and the like to be separated fromlive parts, high temperature parts, moving parts and/orsharp edges for the prevention of electric shock and firehazard. When service is re
15、quired, the original lead routingand dress should be observed, and it should be confirmedthat they have been returned to normal, after reassem-bling.(5) Leakage shock hazard testingAfter reassembling the product, always perform an isola-tion check on the exposed metal parts of the product (an-tenna
16、terminals, knobs, metal cabinet, screw heads,headphone jack, control shafts, etc.) to be sure the productis safe to operate without danger of electrical shock.Do notuse a line isolation transformer during this check. Plug the AC line cord directly into the AC outlet. Using a“Leakage Current Tester“,
17、 measure the leakage currentfrom each exposed metal parts of the cabinet, particular-ly any exposed metal part having a return path to thechassis, to a known good earth ground. Any leakage cur-rent must not exceed 0.5mA AC (r.m.s.). Alternate check methodPlug the AC line cord directly into the AC ou
18、tlet. Use anAC voltmeter having, 1,000 per volt or more sensitivityin the following manner. Connect a 1,500 10W resistorparalleled by a 0.15F AC-type capacitor between an ex-posed metal part and a known good earth ground.Measure the AC voltage across the resistor with the ACvoltmeter. Move the resis
19、tor connection to each exposed metalpart, particularly any exposed metal part having a returnpath to the chassis, and measure the AC voltage acrossthe resistor. Now, reverse the plug in the AC outlet andrepeat each measurement. Voltage measured any mustnot exceed 0.75 V AC (r.m.s.). This corresponds
20、 to 0.5mA AC (r.m.s.). 1.2 Warning(1) This equipment has been designed and manufactured tomeet international safety standards.(2) It is the legal responsibility of the repairer to ensure thatthese safety standards are maintained.(3) Repairs must be made in accordance with the relevantsafety standard
21、s.(4) It is essential that safety critical components are replacedby approved parts.(5) If mains voltage selector is provided, check setting for localvoltage.1.3 CautionBurrs formed during molding may be left over on some partsof the chassis. Therefore, pay attention to such burrs in the case of pre
22、-forming repair of this system.1.4 Critical parts for safetyIn regard with component parts appearing on the silk-screenprinted side (parts side) of the PWB diagrams, the parts that areprinted over with black such as the resistor ( ), diode ( )and ICP ( ) or identified by the “ “ mark nearby are crit
23、icalfor safety. When replacing them, be sure to use the parts of thesame type and rating as specified by the manufacturer. (This regulation dose not Except the J and C version)Good earth groundPlace this probe on each exposedmetal part.AC VOLTMETER(Having 1000 ohms/volts,or more sensitivity)1500 10W